IriInstallation works of fresh-keeping cold storageThe development of the industrial market will tend to grow steadily

announcer:hp632HP195506591 release time:2021-12-16 11:04:54

Judge the operating sound of the compressor, and carefully listen to the operating sound of water pump, cooling tower, compressor, fan and other equipment. In case of abnormal sound, timely warranty is required, good permeability to water vapor, and state of foam pores. It is not connected with each other, and the obturator rate is more than 95%. It is a dense microporous foam material, which is more dense than the surface of the air, and is not easy to permeate. It is an hydrophobic material.

Iri.If the relative flow changes little, there is little difference in power consumption among several regulation modes, that is, the regulation mode has little impact on the energy-saving effect, or even does not save energy, but consumes more power due to the existence of the regulation device, and the variable speed regulation curve is close to the ideal curve. Therefore, the variable speed regulation mode is superior, but the frequency conversion device needs to be added. It is recommended to actively try out the variable frequency speed regulation of small and medium capacity. Due to the high capacity and high voltage variable frequency speed regulation device it should be combined with the specific situation and comprehensive comparison. Generally speaking, the greater the regulation depth, the more significant the energy-saving effect.

Anti odor floor drain shall be set on the pavement of refrigeration room and refrigeration unit room, and the height width ratio of floor drain water seal shall not be less than 50mm. The elevator shaft, electronic pit and other places convenient for drainage shall be provided with drainage and equipment to avoid backflow of water.

.All wiring shall be neat. All switches and keys shall be opened and closed sensitively, reliably and accurately. Special connectors shall be used for wiring, and power protection shall be provided for the box and each power branch.

First, use a hammer to pad the wood on the polyurethane warehouse board between the two warehouse boards, and the two sets of connecting pieces shall be fixed on the upper, outer and lower sides of the gap between the wall panel and the wall panel respectively. The lower connecting piece shall be as close as possible to the lower side, so that the post cast concrete can cover the connecting piece. After the gap between the plate and the plate ground is wedged with a connector, it shall be about 3mm wide. If it does not meet the requirements, remove the plate, trim the plate edge, and then reinstall it to make the plate joint meet the requirements. When fixing the adapter, pay attention to fix the two parts of the adapter on the edges of the convex and concave library plates respectively and fix them with rivets. The spacing of the adapter should be able to tension the two library plates. When wedging the wedge iron, the hammer shall be perpendicular to the wedge iron to prevent damaging the warehouse plate. The ground wedge iron at the upper and lower parts shall be wedged at the same time, and the wedge iron shall be fixed with rivets.

The selection of cold storage is very important for cold storage, because cold storage is different from ordinary cold storage. The temperature in cold storage is usually low, and the air temperature, humidity and environmental requirements are relatively high. When selecting cold storage, attention must be paid to the selection of cold storage with better temperature. If the selection of cold storage is not good, the temperature in the cold storage is difficult to, which is easy to cause the deterioration of products in the cold storage, or the refrigeration compressor in the cold storage often works, wasting more resources and increasing the cost.


IriInstallation works of fresh-keeping cold storageThe development of the industrial market will tend to grow steadily



When opening and drilling is required for the top warehouse plate or wall plate, the internal and external setting out and positioning shall be carried out according to the drawing design requirements, and the opening and drilling shall be carried out after review; The inlet hole, liquid inlet hole, return hole, water supply hole and drainage hole shall be opened with a hole opener. Construction treatment shall be carried out in time after opening and drilling, and the orifice shall be closed with foaming material or sealant to prevent air leakage and cold running; The door, vent and delivery port shall be decorated with wrapped edges and fixed with pull rivets, with a spacing of 300mm and 150mm outside.

The installation of refrigeration pipeline requires that the diameter of copper pipe shall be selected in strict accordance with the interface of compressor suction and exhaust valve. When the separation between condenser and compressor exceeds 3M, the pipeline diameter shall be increased.

2 - cold storage

Lets see.Quick freezing storehouse is widely used. There are many kinds of temperature in quick freezing storehouse, and multi temperature or double temperature can be realized to meet the needs of different customers. Fault phenomena: unit current is large and voltage is too low; Loose wiring; The unit pressure exceeds the rated pressure; The oil separation core is blocked; Device failure; Host failure; Main motor fault; Fault phenomenon: the unit cannot be started and the fuse is broken; The temperature switch is broken; Loose wiring; Thermal relay of main motor acts; The thermal relay of cold storage fan motor acts; The transformer is broken; No power input (unit); Failure not eliminated (unit); The actuator is faulty.

1 - floor installation of cold storage: first level the floor, then install the floor, select a beautiful floor and put it in a conspicuous place and do a good job in the floor and evaporator drainage system.

During the installation of polystyrene storehouse, the Perpendicularity Error of wall plate shall be corrected while the top storehouse plate is installed. The length of the top warehouse plate shall be 10mm shorter than the surface of the wall plate. After the installation of the top warehouse plate, the 10mm gap shall be marked with foaming material to ensure the sealing performance of the warehouse body.


IriInstallation works of fresh-keeping cold storageThe development of the industrial market will tend to grow steadily



Installation of unit electrical box: the unit electrical box shall be installed near the unit; Vertical installation. If the unit is installed on the top of the warehouse, the distance between the box bottom and the top of the warehouse must be & amp; amp; gt; 100 mm; The electrical box can be fixed on the building wall or on the angle steel frame.

quality.Polyurethane with good fire resistance and flame retardancy is a kind of refractory and self extinguishing material after adding flame retardant. In case of fire, it can be carbonized, unlike flow burning and flashover like extruded board, which can effectively prevent fire spread. In particular, it can be sealed as a whole after systematic fire prevention treatment to form non combustible products.

When the ceiling fan is too heavy, 4 or 5 angle iron shall be used as lintel. Lintels shall span over another roof and wall panel to reduce load.

The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration, it shall be able to ensure the reliable power supply of the exhaust fan. The overload protection of the exhaust fan should be applied to the signal alarm system without directly stopping the exhaust fan. The button box of the exhaust fan shall be concealed in the wall outside the ammonia compressor room.

Iri.It is equipped with temperature compensation to automatically adjust the water temperature. The water temperature of ultrasonic atomization is 15-20 degrees. If our humidifier is connected with the warehouse, there is no temperature compensation, even if

When the cold storage is used for the first time or shut down for a long time, it is strictly prohibited to stack goods in the warehouse. The warehouse must be slowly reduced to the required temperature. For the low-temperature warehouse, it needs to be cooled in stages to avoid sudden changes in the temperature difference inside and outside the warehouse resulting in the warehouse body.

The cooking materials and foods refrigerated in the quick-frozen warehouse contain a certain amount of fat, protein and starch. The existence of these nutrients will make molds and bacteria multiply and grow in large numbers. In order to do a good job in the hygienic management of cold areas and ensure the refrigeration quality of food and cooking raw materials