Daniel-FloresCold storage engineeringLow impact toughness

announcer:hp632HP195506591 release time:2022-03-26 09:05:28

At ordinary times, users should check the sealing degree of the gap of the cold storage, and notify the cold storage for maintenance in time if damaged parts are found.

Large space rate of quick-frozen warehouse: for quick-frozen warehouses of the same size reasonable design schemes store more goods than unreasonable ones. For the fixed size quick freezing warehouse, how to design it to maximize its space rate is often an important problem considered by our designers. In the design scheme of Lukang medical quick-frozen warehouse, we reasonably designed to expand the original storage capacity of 300 boxes to 400 boxes, which increases the space a lot.

Daniel-Flores.How to judge whether the controlled atmosphere storage is bad and the effect is poor? Under the same conditions, the required temperature can be reached in 10 minutes, but now it takes 30 minutes. In this way, the refrigeration is obviously slow and the effect is poor, which will directly affect the use cost.

Disadvantages of multi-layer cold storage: the vertical transportation volume of the warehouse is large, and the goods in and out and operation management are not as convenient as single-layer cold storage; With the development of the floor load capacity, large construction equipment is required and the construction period is long.

.Where do you need to build the refrigerator the foundation construction is complex. High cost; When prefabricated components are used, storage capacity, ton, cubic meter, frame, box); What products are stored in the built cold storage? The actual storage temperature, storage time and setting temperature can be indicated by specific regulations; If your cold storage becomes larger, you need to master your individual storage volume, the temperature of goods in and out of the warehouse, the frequency of opening and closing the door, etc. If this is clear, it is the selection of raw materials, such as refrigeration compressors, refrigeration units, industrial cooling fans / pipe slots, thermal insulation materials, coolers, doors, temperatures and other refrigeration equipment.

In order to ensure the safety of construction and cold storage operation, the span between the top storage plate supports (lifting points) shall comply with the following provisions: the polystyrene top storage plate (100mm thick) has a very large span of 3M, and the polyurethane top storage plate (100mm thick) has a span of 5m.

These measures have achieved quite good results. Compared with several cold storages at a customer in Jining, the transportation convenience of cold storage construction site should be given priority in site selection, such as proximity to roads, railways, etc. At the same time, the location of the cold storage should avoid large pollution sources and direct sunlight, and the construction of the cold storage should have good drainage and ventilation conditions.

Scroll refrigeration unit: at present, scroll refrigeration unit is mainly in fully enclosed structure, which is mainly used in air conditioning (heat pump)

The physical properties of polyurethane insulation board are relatively good, which can meet different needs. The polyurethane insulation board is also strict in the selection of materials. It is a special product manufacturing enterprise integrating R & D, and service. It has long been specialized in cold storage installation, cold storage installation, cold storage construction, Polyurethane insulation board has also become one of the main exterior wall materials.

Finance Department.We should implement regular maintenance and daily maintenance, professional cold storage installation, installation of cold storage cold storage construction, fruit preservation cold storage, medical cold storage, excellent quality and low price, fire resistance - Waterproof - high temperature resistance, strong and durable, safe and reliable, and maintain the operation rate of the compressor.

The ultrasonic town is a patented technology with a shaped energy cover, which increases the effective humidification amount by 50-70% per hour. What are the reasonable aspects of the design of the quick freezing warehouse?

Indirect cooling is that the air in the warehouse is pumped into the air cooling device by the blower. The air is absorbed by the evaporation pipe circling in the cooling device, and then sent to the warehouse for cooling. The advantages of air cooling are rapid cooling, uniform temperature in the warehouse, and can bring harmful gases such as carbon oxide out of the warehouse during storage.


Daniel-FloresCold storage engineeringLow impact toughness



During the production of cold storage, the cold storage will produce fixed length, 10cm thick cold storage plates are selected for high and medium temperature cold storage. The requirements for cold storage engineering plates of low-temperature storage and quick-frozen storage will be higher. Professional cold storage installation, installation, construction, fruit fresh-keeping cold storage and medical cold storage ensure the quality, Guarantee service. Guarantee quality. Your satisfaction is our pursuit! Welcome to inquire. In this case, use 12cm or 15cm thick library board. When you budget the cold storage project, you can make a reservation according to the specific conditions of your cold storage temperature. If you don't make a reservation for the cold storage plate, you should pay attention to the density of the cold storage plate and the thickness of the steel plate when purchasing the cold storage plate. According to the regulations, the cold storage shall be distributed

High value.For the flushing (thawing) drainage pipe in the cold room with different temperature, an exhaust valve equipment shall be set before connecting the flushing (thawing) drainage pipe.

For the installation of refrigeration unit, oil separator shall be installed for semi sealed or fully sealed compressor, and an appropriate amount of oil shall be added in the oil. When the evaporation temperature is lower than - 15 ℃, gas-liquid separator and an appropriate amount of refrigeration oil shall be added.

Judge the operating sound of the compressor, and carefully listen to the operating sound of water pump, cooling tower, compressor, fan and other equipment. In case of abnormal sound, timely warranty is required, so as to avoid greater damage to the compressor due to untimely warranty.

Daniel-Flores.Fire retardant flame retardant and high temperature resistant polyurethane is a kind of flame retardant self extinguishing material after adding flame retardant. Its softening point can reach more than 250 ℃, and it will decompose only at higher temperature. In addition, polyurethane forms carbon deposits on the surface of the foam which helps to isolate the foam below. It can effectively prevent flame spread.

The bacterial action of acid disinfectants is mainly to coagulate the protein in the bacteria. Common disinfectants include lactic acid, bleach, formalin, etc. Specifically, after the fish comes out of the freezer, clean the frost layer on the evaporating pipe group and keep the storehouse temperature below 50 degrees Celsius. Then, according to the volume of 50~100 grams per cubic meter volume of the frozen storeroom, the storeroom door is closed tightly with the sprayer, and the blower is started intermittently, so that the vinegar evaporates and flows in the storehouse, which makes the vinegar absorb a lot of fish smell.

Polyurethane spraying is widely used in large and medium-sized refrigerators. Different well-known brands are produced at different prices, and the product quality is relatively large. However, it is not high-quality or good goods. This is the result of long-term cooperation.