San-RafaelInstallation freezer priceWhat to pay attention to when operating

announcer:hp632HP195506591 release time:2022-03-20 15:48:53

Polyurethane foam: This is also a very common cold storage material. It has strong thermal insulation effect and strong mechanical strength. Now it is widely used and has a good application prospect.

The floor of the cold storage shall be kept as close as possible during use

San-Rafael.If the controlled atmosphere storage works continuously for more than 2000h, medium maintenance shall be carried out. The condenser, evaporator and cooling exhaust pipe shall be overhauled once a month. The maintenance contents are as follows: the condenser, evaporator and cooling drain pipe are cleaned and adjusted, the cooling water distribution device is cleaned and adjusted, the brine distribution device is cleaned and adjusted, the cooling drain pipe is repaired and the pipe leakage fault is eliminated.

There are many kinds of cold storage. According to the material, it can be divided into color steel plate, stainless steel plate and salted steel. Among them, color steel plate has strong anti rust ability, but stainless steel plate has strong anti rust ability, it is divided into flat plate and wave plate. The former is flat after the surface material is formed, without color requirements; The thickness of salted steel plate is 0.5mm, without color requirements; The thickness of PE paint baking board is 0.5mm, 0.8mm ivory white, titanium white and white gray. The most important thing for the cold storage is the applicable temperature of the cold storage. It is divided according to the insulation thickness of the storage plate. The thickness of the sky floor of the 150 mm storage plate is 150 mm, and the thickness of the vertical plate is 160 mm and 100 mm, which is suitable for the insulation conditions of - 25 ℃ ~ - 45 ℃; 100mm storage plate: the thickness of the ceiling plate is 100mm and the thickness of the vertical plate is 110mm, which is suitable for the thermal insulation conditions of 0 ℃ ~ - 25 ℃. The thickness of the ceiling plate and the vertical plate of 60mm storage plate is 60mm, which is suitable for the thermal insulation conditions above 0 ℃. In fact, there are many other classification methods of cold storage. Determined by the current processing technology, it can be divided into standard plate and non-standard plate according to the width and size range of warehouse plate, including standard plate vertical plate width wa = 900mm, heaven and earth plate width WB = 980mm, vertical angle plate W1 = 790mm, W2 = 840mm, W3 = 740mm and W4 = 880. The dimensions of non-standard plates are different from those of Wa, WB and W4.

.1 - precautions for floor installation of cold storage: the floor shall be installed flat, the uneven part shall be leveled with materials, and the locking hook between the plates shall be locked to ensure that the warehouse surface is flat without hollow feeling. (note that if this drainage system is installed outdoors in the north, the drainage pipe shall be insulated).

There are two reasons: the refrigerant charge is insufficient. At this time, just add enough refrigerant.

First, use a hammer to pad the wood on the polyurethane warehouse board between the two warehouse boards so as to make the boards closely close to each other. Two sets of connecting pieces shall be wedged between the wall panel and the wall panel, and the two sets of connecting pieces shall be fixed on the upper, outer and lower sides of the gap between the wall panel and the wall panel respectively. The lower connecting piece shall be as close as possible to the lower side, so that the post cast concrete can cover the connecting piece. After the gap between the plate and the plate ground is wedged with a connector, it shall be about 3mm wide. If it does not meet the requirements, remove the plate, trim the plate edge, and then reinstall it to make the plate joint meet the requirements. When fixing the adapter, pay attention to fix the two parts of the adapter on the edges of the convex and concave library plates respectively, and fix them with rivets. The spacing of the adapter should be able to tension the two library plates. When wedging the wedge iron, the hammer shall be perpendicular to the wedge iron to prevent damaging the warehouse plate. The ground wedge iron at the upper and lower parts shall be wedged at the same time, and the wedge iron shall be fixed with rivets.


San-RafaelInstallation freezer priceWhat to pay attention to when operating



When installing polyurethane insulation board, ensure that its surface is smooth and flat without scratch and warpage.

The ventilation device is adopted, which also produces heat exchange with the outside air, resulting in & amp; amp; quot; Heat leakage & amp; amp; quot;, Energy is wasted, so an air scrubber is required. Washing, amino, activated carbon, sieve etc.

The quantity is large, and a special tally room (area) is set according to the needs of production and operation. The temperature of the tally area is usually controlled at 0 ~ + 7 ℃.

Quality risk.Requirements for refrigeration equipment in quick freezing warehouse: the strict sealing of quick freezing warehouse is obviously different from that of ordinary quick freezing warehouse. Therefore, how to seal the refrigeration equipment is the key. First of all, all through wall pipelines must be equipped with sleeves, the frost flushing water return pipeline must be equipped with U-shaped bend water seal, and the main frost flushing and return pipeline outside the warehouse shall be equipped with air filling port to prevent the gas in the warehouse from being pumped out of the warehouse by negative pressure. In addition, due to the good sealing of the quick freezing warehouse, the set fluctuation range of the warehouse temperature should not be too large to prevent excessive positive and negative pressure from damaging the warehouse body.

Thermal insulation rigid polyurethane has low thermal conductivity and good thermal performance. When the density of rigid polyurethane is 35 ~ 40kg / m3, the thermal conductivity is only 0.018 ~ 0.024w / (m.k), which is the lowest among all thermal insulation materials at present.

The height of the warehouse, the horizontal and vertical of the warehouse shall be designed according to the refrigeration, refrigeration equipment transportation and stacking conditions. The selection of insulation board is very important for Guangdong cold storage. At present, the vast majority of cold storage use polyurethane insulation board. What are the characteristics and advantages of polyurethane insulation board?


San-RafaelInstallation freezer priceWhat to pay attention to when operating



When hot ammonia defrosting or electric defrosting is selected as the cooling fan, professional cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage safety, environmental protection and economy! The products are exported to foreign countries and are deeply trusted. Defrosting and drainage can be discharged immediately. Electric heat tracing and insulation can be selected for the defrosting and drainage pipeline of the warehouse location.

Good reputation.The foaming technology of polyurethane with strong stability makes it have superior bonding performance. The firm combination of polyurethane rigid foam and carrier layer is the basic premise to ensure the stability of external insulation layer. That is, under the unfavorable local temperature and humidity conditions, it can bear various internal and external combined loads such as wind force, and the insulation layer still does not separate and fall off from the carrier layer and remains stable in the state.

The ground should be flat and not uneven. If the ground is uneven, the ground of the warehouse must be leveled before the cold storage can be built and installed.

It is equipped with temperature compensation to automatically adjust the water temperature. The water temperature of ultrasonic atomization is 15-20 degrees. If our humidifier is connected with the warehouse, there is no temperature compensation, even if

San-Rafael.Cold storage construction: which one is suitable for you? Which one is suitable for you?

Energy saving and power saving: the design cost of quick freezing warehouse mentioned above is very low but it has a great impact on the cost of quick freezing warehouse and later use cost. The electricity bill is often an important expenditure item in the later stage. The design scheme of the show can greatly reduce the power consumption of the quick freezing warehouse. The selection of the back sunny side of the quick freezing warehouse, the selection of the thickness of the thermal insulation board should be appropriate, and the temperature difference between the adjacent cold storage rooms should not be too large are all issues that we need to consider. There are also some tips, such as the use of air curtain machine on the quick freezing warehouse door. We remind users to use parallel units in quick freezing warehouse as far as possible and start them reasonably.

Cold storage has strong stability. Polyurethane foam technology makes it have superior bonding performance. The firm combination of polyurethane rigid foam and carrier layer is the basic premise to ensure the stability of external insulation layer. That is, under the unfavorable local temperature and humidity conditions, the characteristics of the cold storage still do not separate and fall off from the carrier layer and remain stable under normal conditions.