ColimaHow much is the installation of small cold storageWhat technologies and materials should be available before construction

announcer:hp632HP195506591 release time:2022-03-22 09:22:53

Application of parallel compressor in cold storage: the requirement of refrigeration capacity is large, and 5 to 50 refrigeration compressors under 20 Malige need to be used on weekdays; Long term operation, large load peak valley difference and significant departmental load; Frozen and refrigerated objects are novel foods that are easy to decay and degenerate, and have strict requirements for temperature and humidity.

The equipment configuration is reasonable and the service life of the quick freezing warehouse is long. The reasonable equipment configuration of the quick freezing warehouse can greatly prolong the service time of the quick freezing warehouse. Some compressors are easy to be damaged when they work at full load for a long time, so we try to use screw parallel units. The great advantage of this unit is that it can turn on all equipment just like the shift at work, so that the compressor can work and rest in turn.

Colima.Mark the name on each filter.

Secondly, since the cooling of the compressor is not continuous, the multi work operation at night can be selected if possible. When working at night, the external temperature is low, the cooling water temperature is reduced, and the condensation pressure and condensation temperature are reduced. The cooling capacity of the sampling system, coupled with the equal role of the cold storage board, reduces the power operation of the compressor and achieves the purpose of energy saving.

.The installation of cold storage board is a link of the cold storage installation project. High price cold storage installation of various specifications, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage. Waste merchants, industry, enterprises and power departments are welcome to visit and negotiate! The cold storage body and storage plate include: floor, vertical plate and ceiling plate. The installation of storage plates in different directions and precautions are as follows: enter the construction site, verify the construction situation according to the construction drawings, determine the equipment installation position, and then refer to the following specifications.

The cold storage belongs to a kind of refrigeration equipment. Compared with the refrigerator, its refrigeration area is large, but they have the same refrigeration principle. So how to maintain the cold storage every day. Today I'll introduce how to do a good job in the daily management and maintenance after the installation of the cold storage.

During the production of cold storage, the cold storage will produce fixed length, width and thickness according to the needs of various cold storage projects. Generally, 10cm thick cold storage plates are selected for high and medium temperature cold storage. The requirements for cold storage engineering plates of low-temperature storage and quick-frozen storage will be higher. Professional cold storage installation, installation, construction, fruit fresh-keeping cold storage and medical cold storage ensure the quality, Guarantee service. Guarantee quality. Your satisfaction is our pursuit! Welcome to inquire. In this case, use 12cm or 15cm thick library board. When you budget the cold storage project, you can make a reservation according to the specific conditions of your cold storage temperature. If you don't make a reservation for the cold storage plate, you should pay attention to the density of the cold storage plate and the thickness of the steel plate when purchasing the cold storage plate. According to the regulations, the cold storage shall be distributed


ColimaHow much is the installation of small cold storageWhat technologies and materials should be available before construction



Another reason is that there are many refrigerants in the system. In this case, find the leakage point first, repair the found part and then fill in sufficient refrigerant.

The exhaust temperature of the compressor in the fresh-keeping warehouse can be read out from the thermometer on the exhaust pipeline. It is related to the adiabatic index, compression ratio and suction temperature of refrigerant. The higher the suction temperature, the greater the compression ratio, the higher the exhaust temperature, type and budget of the cold storage.

Quality inspection report.During installation, the plates shall be handled with care. Rough operation is strictly prohibited. Burrs shall be removed at the cutting opening to prevent scratching the plate surface and workers.

Step of cold storage design: define the volume of the cold storage warehouse. The size of the cold storage should be based on the design of a large number of agricultural products to be stored for a long time. This volume is calculated based on the essential volume of stored goods accumulated in the cold storage, plus the row to row corridors, the indoor space between the pile and the wall, such as working intermediate, packaging and combing room, special tool warehouse, loading and unloading platform, etc.

Pay attention to the energy saving of the lighting system: the lighting of the cold storage should be considered comprehensively according to the area, height and warehouse temperature of the cold storage on the basis of safety, science and rationality, from the perspective of energy saving and environmental protection. The lighting in the cold storage is concentrated in the working area.


ColimaHow much is the installation of small cold storageWhat technologies and materials should be available before construction



Features of quick freezing warehouse: the quick freezing technology is advanced, the frost free quick freezing method is adopted, the famous brand compressor and refrigeration accessories are configured, and the automatic frost is adopted. The method can only be used by microcomputer. The refrigeration system adopts green refrigerant, which belongs to the international advanced refrigeration technology in the 21st century.

Which one is better.The two sets of connectors between the cold storage shall be wedged tightly, and the two sets of connectors shall be fixed at the upper, so as to facilitate the use of concrete to cover the connector in the future.

The customer specifies the refrigeration and conversion conditions required by the customer, the temperature of refrigeration and refrigerant, and the provisions of the customer's application site and application installation level.

Cold storage design step: the selection of cold storage refrigeration system the selection of cold storage refrigeration system is mainly the use of cold storage refrigeration compressor and air conditioning evaporator. Generally, small and medium-sized refrigerators are dominated by fully enclosed refrigeration compressors. Due to the small output power of the fully enclosed refrigeration compressor, the price is relatively cost-effective; Small and medium-sized refrigerators are generally dominated by semi closed refrigeration compressors; Semi closed refrigeration compressor is adopted for large and medium-sized refrigerated warehouses. When adopting, ammonia refrigeration unit can also be considered. Because the output power of ammonia refrigeration unit is large and can be used for machine use but the installation and management of refrigerated warehouses are cumbersome. When using the air-conditioning evaporator, the high-temperature cold storage uses the industrial cold fan as the air-conditioning evaporator. Its characteristic is that the temperature reduction speed is faster, but it is easy to lead to the water consumption of the cold collection; Medium and ultra-low temperature refrigerators are dominated by seamless evaporation pipe slots, which is characterized by very good temperature control effect and moderate cold storage.

Colima.Grasp the key points. Now let's analyze the production and use requirements of the cold storage. There is no condensation in the cold storage. Condensation in the cold storage or in the insulation layer is harmful. During the drying process of the new wall or under winter conditions, when the water vapor with high indoor temperature migrates outdoors, it is impossible to condense in the wall due to the obstruction of the cold storage.

Generally, in the actual operation of the refrigeration system, because the temperature conditions are constantly changing, only by relying on the careful operation of the cold storage management personnel and accurately adjusting the operation of the refrigeration equipment of the cold storage can the refrigeration system always be in the ideal working state and achieve the effect of energy saving.

Drainage measures shall be provided for the villa room and overhead layer of the road surface of the cold storage engineering building.