SeogwipoHow much is it to install a small cold storageBriefly describe daily failures and solutions

announcer:hp632HP195506591 release time:2021-12-16 11:16:01

Simple refrigeration is based on the volatilization of refrigerant in the condenser of the cold storage, so as to cool the refrigerant, and then input the refrigerant into the box or building of the refrigeration equipment to cool the air according to the heat exchanger. This kind of refrigeration has slow cooling speed, large total heat conduction temperature difference and complex system software, so it can only be used in less places, such as brine ice making and cold storage with constant temperature requirements.

Various construction materials, such as material certificate, test report and stage acceptance record, shall be carried out simultaneously with the project construction, carefully, timely, accurately and comprehensively reflect the whole process of production and construction, and actively cooperate with the owner in design change and technical negotiation.

Seogwipo.All equipment connections shall be laid with wire pipes and fixed with clips. PVC wire pipes shall be bonded with glue, and the pipe orifice shall be sealed and wrapped with adhesive tape.

The equipment configuration is reasonable and the service life of the quick freezing warehouse is long. The reasonable equipment configuration of the quick freezing warehouse can greatly prolong the service time of the quick freezing warehouse. Some compressors are easy to be damaged when they work at full load for a long time, so that the compressor can work and rest in turn.

.Danfoss thermal valve is adopted for the thermal valve of the cold storage just like the shift at work, with guaranteed quality; Due to the high temperature requirements of the cold storage and the high degree of automation and regulation of the temperature, the temperature system of the cold storage adopts microcomputer full-automatic, does not need special people to operate, and can be remotely controlled. When the temperature exceeds the specified range, it will automatically alarm, which is of great significance to the proper preservation of the cold storage.

Installation of box and operating device: the design of box shall be reasonable, and the appearance quality shall meet the requirements of beauty and practicality. All buttons, etc. shall be reliable, safe, long-term cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage, price advantage and quality guarantee! Easy to identify and operate. The indicator light shall be simple and clear. The device and each switch shall be installed on the upper side outside the warehouse door, which is easy to operate, read data and not easy to be damaged, and shall be reliably fixed. The device box is installed on the door frame plate on the door opening side. The center line of the box overlaps the center line of the door frame plate. The bottom of the box is 1800mm above the ground and is reliably fixed. The lighting lamp and door frame wire switch in the warehouse are installed directly below the device, and the height of the bottom edge of the switch box is about 1400mm.

2 - cold storage


SeogwipoHow much is it to install a small cold storageBriefly describe daily failures and solutions



In order to maintain a constant low temperature in the cold storage, attention should be paid to the installation of cold storage panels in Guizhou: the floor, wall and flat roof of the cold storage are laid with a certain thickness of thermal insulation materials to reduce the incoming heat from the outside. In order to reduce the absorption of solar radiation, the surface of the external wall of the cold storage is painted white or light color. Therefore, cold storage building is different from general industrial and civil buildings, and has its unique structure. Cold storage buildings should prevent the entry of air and the diffusion of water vapor.

Flow temperature and water body of surface water around the construction area of surface water and water resources cold storage.

Generally, in the actual operation of the refrigeration system, because the temperature conditions are constantly changing, only by relying on the careful operation of the cold storage management personnel and accurately adjusting the operation of the refrigeration equipment of the cold storage, can the refrigeration system always be in the ideal working state and achieve the effect of energy saving.

production costs.During the use of the goods yard medical cold storage project, the stored goods must be in strict accordance with the relevant regulations. The goods should have a certain distance from the ground and wall of the cold storage. When stacking, the distance between the goods and the goods must be cm. At the same time the distance between the goods and the cold fan should also be 100 cm. No goods can be stored within this range, This is also an important content in the use of medical cold storage engineering.

Fire retardant, flame retardant and high temperature resistant polyurethane is a kind of flame retardant self extinguishing material after adding flame retardant. Its softening point can reach more than 250 ℃, and it will decompose only at higher temperature. In addition, polyurethane forms carbon deposits on the surface of the foam, which helps to isolate the foam below. It can effectively prevent flame spread.

The cold storage board uses light polyurethane as the inner material of the cold storage board. The advantage of polyurethane is that the thermal insulation performance is very good. The exterior of polyurethane cold storage board is composed of SII, PVC color steel plate and stainless steel plate. The advantage of this is to prevent the temperature transmission of cold storage board due to large internal and external temperature difference, so as to make the cold storage more energy-saving and improve the working efficiency of cold storage.


SeogwipoHow much is it to install a small cold storageBriefly describe daily failures and solutions



Disadvantages of multi-layer cold storage: the vertical transportation volume of the warehouse is large, and the goods in and out and operation management are not as convenient as single-layer cold storage; With the development of the floor load capacity, the floor area ratio of each cold room is low; When the multi-storey cold storage is built on the foundation with poor ground resistance, the foundation construction is complex. High cost; When prefabricated components are used, large construction equipment is required and the construction period is long.

Installation material list.Fault phenomenon: fan motor overload, fan deformation; Fan motor fault; Fan motor thermal relay fault (aging); Loose wiring; Cooler blocked; Large exhaust resistance. Fault phenomenon of cold storage: the dryer does not operate, the compressor line is disconnected, the fuse is blown, the high-voltage switch acts, the compressor is locked, the line is falsely connected or loose. Fault phenomenon: it stops in a short time after the drying motor, and the environment

Heat pump, hot water refrigeration and other fields. Supporting downstream products include: household air conditioner, multi on-line, modular machine, small water ground source heat pump, etc. At present, a single scroll refrigeration unit can achieve 20 ~ 30HP.

Different food processing technical processes for the construction of cold storage are combined with local urban planning. The construction of cold storage is the design requirements and construction of cold storage, which not only avoids the cross pollution between foods, but also ensures its transportation facilities: within the construction scope a reasonable overall layout, saves land and reduces costs.

Seogwipo.In order to maintain a constant low temperature in the cold storage, attention should be paid to the installation of cold storage panels in Guizhou: the floor, the surface of the external wall of the cold storage is painted white or light color. Therefore, cold storage building is different from general industrial and civil buildings, and has its unique structure. Cold storage buildings should prevent the entry of air and the diffusion of water vapor.

Refrigeration system: refrigeration system is the core part of cold storage design. It is the key to determine the economy, environmental protection and performance of cold storage.

Initial operation unit of cold storage equipment: regularly observe the oil level and oil return of the compressor and the cleanliness of the oil. If the oil is dirty or the oil level drops, it shall be solved in time to avoid adverse effects.