Kampung sungaiara VillageCold storageAre there any installation tips

announcer:hp632HP195506591 release time:2021-12-11 17:22:57

Compression refrigerator is commonly used, which is mainly composed of compressor, condenser, throttle valve and evaporation pipe. According to the way of evaporation pipe device, it can be divided into direct cooling and indirect cooling. Direct cooling the evaporation pipe is installed in the refrigerated warehouse. When the liquid coolant passes through the evaporation pipe, it will directly absorb the heat in the warehouse and cool down.

When the cold storage is built, the diffusion of water vapor and the infiltration of air shall be prevented. When outdoor air invades, it will not only increase the cold consumption of the cold storage, but also bring moisture into the warehouse. Moisture condensation will damp the heat insulation structure and freeze and damage the cold storage structure. Therefore it is necessary to set moisture-proof and heat insulation layer, installation of cold storage professional cold storage installation, cold storage construction, fruit fresh-keeping cold storage, medical cold storage and other products, which have a complete variety, sell well at home and abroad, and have a long service life! Products lead the wire industry. Welcome to inquire, so that the cold storage building has good sealing, moisture-proof and steam isolation performance.

Kampung sungaiara Village.Vacuum test: after the pressure test of the fresh-keeping storehouse system is qualified, the vacuum leakage test of the fresh-keeping storehouse system can be carried out. The purpose is to improve the air tightness under the vacuum condition of the fresh-keeping warehouse and prepare the conditions for the ammonia filling of the fresh-keeping warehouse system.

The polyurethane insulation board used in the construction of cold storage shall be integral and continuous, and there shall be no joint in the middle. The junction of polyurethane insulation board, top plate and ground shall be made into fillet arc for transition, which can well meet the health needs.

.The polyurethane insulation board shall be connected by plug-in notch connection, because it has higher strength when connecting in this way.

In order to ensure the safety of construction and cold storage operation, the span between the top storage plate supports (lifting points) shall comply with the following provisions: the polystyrene top storage plate (100mm thick) has a very large span of 3M, and the polyurethane top storage plate (100mm thick) has a span of 5m.

The quick-frozen warehouse is easy to load and unload. All the plates and walls of the quick-frozen warehouse are produced by molds. You can choose tens of millions of products. Professional cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage and transaction safety are guaranteed. Through internal concave convex groove connection, loading, unloading and handling are convenient. The installation period is short. Small and medium-sized cold storage can be delivered in 2-5 days, separated or increased or decreased according to the needs of users.


Kampung sungaiara VillageCold storageAre there any installation tips



Disadvantages of single-layer cold storage: large; The surface area of the external enclosure structure of the cold storage is large, and the dry consumption of cold food is also large; For the low-temperature warehouse the floor anti freezing treatment requires a large amount of work. When the cold storage is built at the water level, it is impossible to deal with it, which is easy to cause horizontal freezing and swelling.

The location of fresh-keeping warehouse installation shall be in a stable and convenient place; (if it is a local fruit farmer, it should be installed near the fruit source)

The height of the warehouse, the horizontal and vertical of the warehouse shall be designed according to the refrigeration, refrigeration equipment, transportation and stacking conditions. The selection of insulation board is very important for Guangdong cold storage. At present, attention shall be paid to the collision and scratch of the storage body to avoid the depression and corrosion of the storage plate, which will seriously reduce the local thermal insulation performance of the storage body.

The new cold storage material is made of rigid polyurethane or polystyrene foam insulation sandwich panel, which is made by high pressure foaming process and can be made into various lengths and specifications to meet the different requirements of the users.

Energy saving and power saving: the design cost of quick freezing warehouse mentioned above is very low, but it has a great impact on the cost of quick freezing warehouse and later use cost. The electricity bill is often an important expenditure item in the later stage. The design scheme of the show can greatly reduce the power consumption of the quick freezing warehouse. The selection of the back sunny side of the quick freezing warehouse, the selection of the thickness of the thermal insulation board should be appropriate, the tightness of the quick freezing warehouse door, and the temperature difference between the adjacent cold storage rooms should not be too large are all issues that we need to consider. There are also some tips, such as the use of air curtain machine on the quick freezing warehouse door. We remind users to use parallel units in quick freezing warehouse as far as possible and start them reasonably.


Kampung sungaiara VillageCold storageAre there any installation tips



The height of the warehouse, the horizontal and vertical of the warehouse shall be designed according to the refrigeration, refrigeration equipment, transportation and stacking conditions. The selection of insulation board is very important for Guangdong cold storage. At present, the vast majority of cold storage use polyurethane insulation board. What are the characteristics and advantages of polyurethane insulation board?

Price.Installation of box and operating device: the design of box shall be reasonable, and the appearance quality shall meet the requirements of beauty and practicality. All buttons, electrical switches, etc. shall be reliable, safe, long-term cold storage installation cold storage installation, cold storage construction, medical cold storage, 20-year-old brand, price advantage and quality guarantee! Easy to identify and operate. The indicator light shall be simple and clear. The device and each switch shall be installed on the upper side outside the warehouse door, which is easy to operate, read data and not easy to be damaged, and shall be reliably fixed. The device box is installed on the door frame plate on the door opening side. The center line of the box overlaps the center line of the door frame plate. The bottom of the box is 1800mm above the ground and is reliably fixed. The lighting lamp and door frame wire switch in the warehouse are installed directly below the device, and the main parameters cannot be changed at will. All kinds of cold storage installation temperature difference and other main parameters of fresh-keeping warehouse equipment wholesale shall be set according to the specific situation of the frozen warehouse, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage formal qualification, welcome to telephone inquiry, sincerely invite cooperation! The freezer has been customized according to the customer's regulations in the original factory. After mastering the performance parameters of the freezer, set various main parameters on the board.

2 - cold storage

Kampung sungaiara Village.1 - floor installation of cold storage: first level the floor, then install the floor, select a beautiful floor and put it in a conspicuous place, and do a good job in the floor and evaporator drainage system.

Polyurethane refrigeration board uses light polyurethane as the internal material of refrigeration board. The advantage of polyurethane is very good heat insulation. The exterior of the cold storage is composed of SII, PVC color steel plate and stainless steel plate. The advantage of this is that it can prevent refrigeration, because the temperature difference inside and outside the board is large, and the temperature will disperse, which makes refrigeration more energy-saving and improves the working efficiency of refrigeration.

The bacterial action of acid disinfectants is mainly to coagulate the protein in the bacteria. Common disinfectants include lactic acid, bleach, formalin, etc. Specifically, after the fish comes out of the freezer, clean the frost layer on the evaporating pipe group and keep the storehouse temperature below 50 degrees Celsius. Then, according to the volume of 50~100 grams per cubic meter volume of the frozen storeroom, the storeroom door is closed tightly with the sprayer, and the blower is started intermittently, so that the vinegar evaporates and flows in the storehouse, which makes the vinegar absorb a lot of fish smell.