Saint-LouisHow much is it to install a small cold storageHow is it made

announcer:hp632HP195506591 release time:2022-01-14 15:18:23

Immediate cooling is to install the condenser of the cold storage in the box or building of the cooling equipment, use the volatilization of the refrigerant to immediately cool the air in the air, and use the cold air to cool the objects that need to be cooled. This kind of refrigeration is characterized by faster cooling speed, small heat conduction temperature difference and simple system software, so it is widely used.

Requirements for refrigeration equipment in quick freezing warehouse: the strict sealing of quick freezing warehouse is obviously different from that of ordinary quick freezing warehouse. Therefore, how to seal the refrigeration equipment is the key. First of all, all through wall pipelines must be equipped with sleeves, the frost flushing water return pipeline must be equipped with U-shaped bend water seal, and the main frost flushing and return pipeline outside the warehouse shall be equipped with air filling port to prevent the gas in the warehouse from being pumped out of the warehouse by negative pressure. In addition, due to the good sealing of the quick freezing warehouse, the set fluctuation range of the warehouse temperature should not be too large to prevent excessive positive and negative pressure from damaging the warehouse body.

Saint-Louis.Refrigerated vehicle planning Kende refrigeration reminds enterprises with the construction needs of logistics refrigerated warehouse project to conduct in-depth communication with the project and refrigerated vehicle planning on warehouse location and actual use needs when determining the final installation construction mode, so as to ensure the smooth circulation of goods in logistics refrigerated warehouse.

The type of cold storage to be built in the type of cold storage should be determined according to the type of circulating goods. For example, the cold storage that only circulates vegetables can only build a fresh-keeping cold storage, while the cold storage with refrigeration + freezing will be built if there are many types of circulating goods and great difference in storage temperature. As for the size of the cold storage, it should be determined according to the type,Saint-LouisCold storage manufacturer, quantity, frequency, cycle, whether to use shelf stacking and so on. For example, the storage capacity of 280-330kg per cubic meter can be referred to, and the size of cold storage construction can be estimated in combination with the storage capacity rate of about 0.5-0.6.

.The foundation of cold storage is affected by low temperature, and the water in the soil is easy to be frozen. Due to the volume of frozen soil, the ground will be broken and the whole building structure will be deformed. If the damage is serious, it may even make the cold storage unusable. Therefore, in addition to the thermal insulation layer, the floor of low-temperature cold storage must be treated under the thermal insulation layer to prevent soil freezing. The bottom plate of the cold storage shall stack a large number of goods and pass through various loading, unloading and transportation machinery and equipment. Therefore, the structure of the cold storage plate shall be firm and have large bearing capacity. In low temperature environment especially in the process of periodic freezing and thawing cycle, building structures are vulnerable to. Therefore, the structure of each part of the cold storage and the building materials of the cold storage should have sufficient frost resistance.

If there is more air or refrigerant oil in the evaporator the heat transfer effect will be reduced: once more refrigerant oil is attached to the inner surface of the evaporator heat transfer tube, the heat transfer coefficient will be reduced. Similarly, if there is more air in the heat transfer tube, the heat exchange area of the evaporator will be reduced, the heat transfer efficiency will be significantly reduced, and the decline rate of warehouse temperature will be slowed down.

The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration, it shall be able to ensure the reliable power supply of the exhaust fan. The overload protection of the exhaust fan should be applied to the signal alarm system without directly stopping the exhaust fan. The button box of the exhaust fan shall be concealed in the wall outside the ammonia compressor room.


Saint-LouisHow much is it to install a small cold storageHow is it made



The lights in the warehouse are not on. Please check whether the switch fails and whether the bulb is damaged. Cut off the power supply when installing the lampshade, and pay attention to the waterproof of the lamp.

If the refrigerator has been used for more than months, or the high / low voltage switch often fails, or the refrigeration capacity is reduced,Saint-LouisInstallation telephone of fresh-keeping cold storage, please arrange staff to clean the condenser. If the ultra-thin light box is repaired according to the above instructions for many times, and the refrigerator fault still sounds for a long time, please ask the maintenance personnel of the refrigerator to repair it.

Polyurethane spraying is widely used in large and medium-sized refrigerators. Different well-known brands are produced at different prices, and the product quality is relatively large. However, it is not high-quality or good goods. This is the result of long-term cooperation.

Quality improvement.Points of multi-storey cold storage: small, which can save land; When the storage capacity is the same, the surface area of the outer enclosure structure is smaller than that of the single-layer cold storage, so that the cold consumption can be reduced, and the machinery and equipment cost and operation and management cost can be reduced accordingly. At the same time due to the saving of thermal insulation materials, the civil construction cost per unit area is low and the investment cost is small; The multi-storey location can be reasonable, such as the cooling room can be used as the cold storage room, the attic on the top floor can be built into the ice making room, etc.

For the flushing (thawing) drainage pipe in the cold room with different temperature, an exhaust valve equipment shall be set before connecting the flushing (thawing) drainage pipe.

Secondly, since the cooling of the compressor is not continuous, the multi work operation at night can be selected if possible. When working at night, the external temperature is low, and the condensation pressure and condensation temperature are reduced. The cooling capacity of the sampling system, coupled with the equal role of the cold storage board, reduces the power operation of the compressor and achieves the purpose of energy saving.


Saint-LouisHow much is it to install a small cold storageHow is it made



The lights in the warehouse are not on. Please check whether the switch fails and whether the bulb is damaged. Cut off the power supply when installing the lampshade, and pay attention to the waterproof of the lamp.

Online consultation.Indirect cooling is that the air in the warehouse is pumped into the air cooling device by the blower. The air is absorbed by the evaporation pipe circling in the cooling device, and then sent to the warehouse for cooling. The advantages of air cooling are rapid cooling, uniform temperature in the warehouse, and can bring harmful gases such as carbon oxide out of the warehouse during storage.

If the engineering design of logistics cold storage should bear the important responsibility of low-temperature storage and transportation, in addition to paying attention to the planning of the above basic functions, KFC refrigeration suggests that enterprises can also configure the classification, scale, unpacking, packaging, etc. of large packaging, product portfolio packaging, trademark, label pasting and supporting tools according to business needs, So as to better improve the quality of refrigeration distribution center and realize greater value return.

During the use of the goods yard medical cold storage project, the stored goods must be in strict accordance with the relevant regulations. The goods should have a certain distance from the ground and wall of the cold storage. When stacking, the distance between the goods and the goods must be cm. At the same time, This is also an important content in the use of medical cold storage engineering.

Saint-Louis.There are two reasons: the refrigerant charge is insufficient. At this time, just add enough refrigerant.

The bubble density is 38 kg to 40 kg / m3 per cubic meter, and the steel plate thickness generally needs to be more than 0.4 mm to meet the standard. On the market, the main raw materials of special cold storage board for cold storage project are polyphenylene, polyethylene and polyphenylene grease. The density of thermal insulation material foamed by polyphenylene is thin,Saint-LouisMedical cold storage project, and has high load-bearing capacity; Polyphenylene resin has strong water absorption it can foam cold storage insulation materials with appropriate density and good thermal insulation effect, but poor heat insulation. Therefore, the polyurethane sandwich board with very good performance belongs to the polyurethane sandwich board. Although it is slightly higher, the polyurethane board has very good thermal insulation performance and does not absorb moisture.

Cold storage has good fire and flame resistance. After adding flame retardant, polyurethane is a kind of flame retardant and self extinguishing material. If it is burned by fire, it can be carbonized unlike flow burning and flashover like extruded board, which can effectively prevent fire spread. In particular, it can be closed as a whole after fire prevention treatment to form non combustible products.