Saint-PetersburgInstallation of small cold storage equipmentThe risk of price fluctuations

announcer:hp632HP195506591 release time:2022-01-19 09:45:28

Saint-PetersburgWhat refrigerators are installed,

The selection of cold storage is very important for cold storage, because cold storage is different from ordinary cold storage. The temperature in cold storage is usually low, and the air temperature, humidity and environmental requirements are relatively high. When selecting cold storage, attention must be paid to the selection of cold storage with better temperature. If the selection of cold storage is not good, the temperature in the cold storage is difficult to, which is easy to cause the deterioration of products in the cold storage, or the refrigeration compressor in the cold storage often works, when the water vapor with high indoor temperature migrates outdoors, it is impossible to condense in the wall due to the obstruction of the cold storage.

Saint-Petersburg.After evacuation, fill the refrigerant into the liquid storage to 70% of the standard filling volume & mdash; 80% by weight, then run the compressor and add gas from low pressure to sufficient volume.

Moreover, polyurethane does not produce harmful gas at high temperature.

.The wide, light and thin walls are made of rigid polyurethane foam at the same time as structural materials, making the whole structure have the advantages of light weight large span and high load. The thinner polyurethane sandwich plate can meet the relevant provisions on building energy consumption limit, which allows the use of thinner plates during construction and saves building space.

During installation, the plates shall be handled with care. Rough operation is strictly prohibited. Burrs shall be removed at the cutting opening to prevent scratching the plate surface and workers.

Some cold bridge prevention measures shall be taken at the joints between polyurethane insulation boards.


Saint-PetersburgInstallation of small cold storage equipmentThe risk of price fluctuations



The door of the combined cold storage is not tightly closed. Please adjust the distance between the hinge on the door and the door lock and the storage body.

The door hinge, door handle and anti-theft lock of the door of the freezer shall be greased on time according to the specific situation.

Requirements for refrigeration equipment in quick freezing warehouse: the strict sealing of quick freezing warehouse is obviously different from that of ordinary quick freezing warehouse. Therefore, how to seal the refrigeration equipment is the key. First of all, all through wall pipelines must be equipped with sleeves,Saint-PetersburgCold storage installation works, the frost flushing water return pipeline must be equipped with U-shaped bend water seal, and the main frost flushing and return pipeline outside the warehouse shall be equipped with air filling port to prevent the gas in the warehouse from being pumped out of the warehouse by negative pressure. In addition, due to the good sealing of the quick freezing warehouse, the set fluctuation range of the warehouse temperature should not be too large to prevent excessive positive and negative pressure from damaging the warehouse body.

Industry management.The product shade warehouse is a warehouse location below 20 ℃ and the sun cannot be straight. The humidity is 45% ~ 75% relative humidity, and there are corresponding strict requirements for the wall ceiling, disinfection and epidemic prevention of the warehouse. The refrigeration system adopts full-automatic microcomputer electrical technology and does not need to be on duty. It mainly stores western and Chinese grass materials and instruments, and can monitor and record the temperature and humidity in the storage area.

During the early operation of the refrigeration unit, carefully observe the oil return of the compressor and keep it clean. If it is found that the oil level is not clean enough or the oil level drops,Saint-PetersburgInstall fruit preservation cold storage, replace it with new oil in time, so as to avoid bad compressor and reduce the service life of the compressor.

Application of parallel compressor in cold storage: the requirement of refrigeration capacity is large, and 5 to 50 refrigeration compressors under 20 Malige need to be used on weekdays; Long term operation, large load peak valley difference and significant departmental load; Frozen and refrigerated objects are novel foods that are easy to decay and degenerate, and have strict requirements for temperature and humidity.


Saint-PetersburgInstallation of small cold storage equipmentThe risk of price fluctuations



General quick-frozen warehouses are mostly cooled by refrigeration mechanisms, and those with very low gasification temperature are used as coolant to evaporate under low pressure and mechanical conditions, so as to achieve the purpose of cooling and reduction.

Job description.The equipment that needs to be installed in the warehouse and put into the warehouse shall be installed in place or placed in an appropriate position in the warehouse; The wall warehouse board shall be installed from the corner of the warehouse body, and the professional cold warehouse shall be installed. The cold warehouse shall be installed. The cold warehouse shall be constructed. The fruit fresh-keeping cold warehouse and medical cold warehouse shall have high pressure rating, good waterproof performance, fire and high temperature resistance, strong overload capacity, corrosion resistance, radiation protection and long service life. The corner shall be temporarily fixed with 0.5 color plate angle steel; When installing each wall panel, evenly apply two layers of foaming material on the joint surface of male and female groove and apply one layer of foaming material when installing polystyrene wall panel. The blanking shall be uniform and continuous; After the wallboard is installed in place, pull rivets at the lap joint of the internal and external steel plates of the two wallboards for connection and fixation, and the rivet spacing in the warehouse should be 300mm; When connecting the library plate in the form of eccentric hook connection, the eccentric hook shall be loosened once before installation to ensure reliable locking during installation.

Does the unit location meet the relevant conditions? Whether the heat dissipation and pipe length can meet the requirements.

Different food processing technical processes for the construction of cold storage are combined with local urban planning. The construction of cold storage is the design requirements and construction of cold storage, which not only avoids the cross pollution between foods, but also ensures its transportation facilities: within the construction scope, a reasonable overall layout, saves land and reduces costs.

Saint-Petersburg.Before the acceptance and delivery of the project, it shall be treated. There shall be no obvious scratch on the board surface.

Polyurethane with good fire resistance and flame retardancy is a kind of refractory and self extinguishing material after adding flame retardant. In case of fire, it can be carbonized, unlike flow burning and flashover like extruded board, which can effectively prevent fire spread. In particular, it can be sealed as a whole after systematic fire prevention treatment to form non combustible products.

Quick freezing storehouse is widely used. There are many kinds of temperature in quick freezing storehouse, and multi temperature or double temperature can be realized to meet the needs of different customers. Fault phenomena: unit current is large and voltage is too low; Loose wiring; The unit pressure exceeds the rated pressure; The oil separation core is blocked; Device failure; Host failure; Main motor fault; Fault phenomenon: the unit cannot be started and the fuse is broken; The temperature switch is broken; Loose wiring; Thermal relay of main motor acts; The thermal relay of cold storage fan motor acts; The transformer is broken; No power input (unit); Failure not eliminated (unit); The actuator is faulty.