San-PabloInstallation and maintenance of cold storageHow companies save themselves

announcer:hp632HP195506591 release time:2022-03-22 09:10:57

San-PabloInstallation price of vegetable cold storage, and there are corresponding strict requirements for the wall, ceiling, ventilation, disinfection and epidemic prevention of the warehouse. The refrigeration system adopts full-automatic microcomputer electrical technology and does not need to be on duty. It mainly stores western and Chinese grass materials and instruments, and can monitor and record the temperature and humidity in the storage area.

The type of cold storage to be built in the type of cold storage should be determined according to the type of circulating goods. For example, the cold storage that only circulates vegetables can only build a fresh-keeping cold storage, while the cold storage with refrigeration + freezing will be built if there are many types of circulating goods and great difference in storage temperature. As for the size of the cold storage, it should be determined according to the type, quantity, frequency, cycle, for fruits and vegetables packed in cartons, the storage capacity of 280-330kg per cubic meter can be referred to, and the size of cold storage construction can be estimated in combination with the storage capacity rate of about 0.5-0.6.

San-Pablo.Air valve leakage and ring leakage will not only affect the rise of exhaust temperature of fresh-keeping warehouse, but also change the interstage pressure. As long as the compression ratio is higher than the normal value, the exhaust temperature will rise.

Cold storage plate features: good thermal insulation performance, light weight, high strength, corrosion resistance, anti-aging, only with sufficient cold storage installation skills can we ensure that the cold storage is more energy-saving and power-saving after installation, and is not prone to failure, convenient use and management and long service life.

After being stored in the medical cold storage project, ventilating medical products may also emit some odors. Once these odors are stored in a certain quantity, they will also have a certain impact on other products. Therefore, we must carry out regular ventilation in the process of daily use, so as to effectively reduce the storage time of products. If the medical cold storage project uses row tube refrigeration the image of frosting may appear after use for a period of time. If we do not defrost in time, it will also affect the effect of. Therefore, I hope you must pay attention to defrosting.

Wall and floor fixtures shall start at corners. According to the plate layout drawing, transport the two plates at the corner of the required device to the device location. According to the plate beam height and the model of the angle iron for fixing the mushroom head nylon bolt, drill a hole at the corresponding elevation in the middle of the plate width. When drilling, the electric drill should be perpendicular to the plate surface. Put the mushroom head nylon bolt in the hole, tighten the angle iron, and tighten it horizontally so as to make the nylon bolt on the surface of the warehouse plate slightly concave. When setting up the wall panels, foam data and other soft data should be laid on the floor slots along with the floor of the storehouse, so as to avoid damaging the storehouse. After the two corner panels are neutrally removed from the floor, the plane position of the wallboard and the verticality of the storehouse should be adjusted in time according to the location of the laying line, and check whether the top elevation of the wallboard can be correct. After the position of the wallboard is correct, weld the angle iron on the plate beam and fix the inner and outer corners. When welding the angle iron parts, the angle iron parts of the warehouse plate shall be covered with a shield to avoid the high temperature of the welding ground baking the warehouse plate and welding slag on the warehouse plate during electric arc welding.


San-PabloInstallation and maintenance of cold storageHow companies save themselves



Grasp the key points. Now let's analyze the production and use requirements of the cold storage. There is no condensation in the cold storage. Condensation in the cold storage or in the insulation layer is harmful. During the drying process of the new wall or under winter conditions, when the water vapor with high indoor temperature migrates outdoors, which shall be clamped with a wire clamp, and tin shall be hung if necessary.

2 - cold storage

Excellent service.Before the acceptance and delivery of the project, the board surface shall be wiped clean. If there is any scratch, it shall be treated. There shall be no obvious scratch on the board surface.

Goods in and out frequently, throughput

Secondly, since the cooling of the compressor is not continuous the multi work operation at night can be selected if possible. When working at night,San-PabloEnergy saving design of cold storage,San-PabloFood cold storage installation manufacturer, the cooling water temperature is reduced the external temperature is low, and the condensation pressure and condensation temperature are reduced. The cooling capacity of the sampling system, coupled with the equal role of the cold storage board, reduces the power operation of the compressor and achieves the purpose of energy saving.


San-PabloInstallation and maintenance of cold storageHow companies save themselves



Floor insulation of medium-sized cold storage the structure of medium-sized cold storage is what we often call the surface, that is, the top and wall are made of color steel plate / stainless steel with appropriate thickness of polyurethane and other insulation materials, while the ground needs to be insulated separately. At present, the common operations in the market are: laying the ground with XPS extruded board, laying moisture-proof and steam isolating SPS materials above and below the extruded board respectively, and then pouring concrete or reinforced concrete.

Economic management.The temperature is too high, the condenser is blocked in the cold storage, the compressor is overloaded, there is a lack of refrigerant, the low pressure is too low, the air intake is too large, and the compressor is stuck.

A U-bend shall be installed at the outlet of the air return pipe of the cooling fan. The air return pipeline shall slope towards the compressor to ensure smooth oil return.

The construction of cold storage in site selection bears the circulation of low-temperature goods. Therefore, the transportation convenience of cold storage construction site should be given priority in site selection, such as proximity to roads, railways, etc. At the same time the location of the cold storage should avoid large pollution sources and direct sunlight, and the construction of the cold storage should have good drainage and ventilation conditions.

San-Pablo.According to the size and nature of the cold storage area and in combination with local regulations, the construction form of food cold storage warehouse is to determine the plane layout based on the site, whether it is a single-layer or double-layer warehouse, and the structure is the selection of steel structure or reinforcement solidification. Cold storage capacity, refrigeration, product stacking, temperature, etc. are used to determine the size and location of the cold storage room, so that it can become a whole.

With the increasing use of cold storage, cold storage board, as an important structure of cold storage, is also increasing. Because cold storage is different from other ordinary cold storage, it is important to the installation environment and temperature. Therefore, some small problems may be ignored during installation. According to the following understanding.

However, long-term continuous operation will inevitably lead to equipment aging, so reasonable maintenance is particularly important.