ConcepcionSmall installation of cold storageWhat are the advantages in practical applications

announcer:hp632HP195506591 release time:2022-03-24 09:21:35

In order to ensure the safety of construction and cold storage operation, the span between the top storage plate supports (lifting points) shall comply with the following provisions: the polystyrene top storage plate (100mm thick) has a very large span of 3M, and the polyurethane top storage plate (100mm thick) has a span of 5m.

Installation of refrigeration equipment. The refrigeration system of the cold storage includes evaporator and units outside the cold storage. All equipment shall be installed in accordance with the construction specifications, and corresponding protection measures shall be taken for the installed equipment.

Concepcion.The electric cabinet shall be in strict accordance with the requirements of the drawing,ConcepcionCold storage design and installation plant, and the power shall be connected for no-load test.

Clean and professional cold storage installation, cold storage installation, cold storage construction, fruit fresh-keeping cold storage, safety, and it must not be knocked during cleaning, so as not to damage the ground and affect the service life of the cold storage.

.According to the size and nature of the cold storage area and in combination with local regulations, the construction form of food cold storage warehouse is to determine the plane layout based on the site, whether it is a single-layer or double-layer warehouse, and the structure is the selection of steel structure or reinforcement solidification. Cold storage capacity, production process, refrigeration product stacking, temperature, etc. are used to determine the size and location of the cold storage room, so that it can become a whole.

The cold storage shall be regularly overhauled and maintained, so as to reduce the failure rate of the refrigeration unit and achieve good refrigeration effect.

With the development of the times, refrigeration devices are becoming more and more common. All aspects of life are inseparable from its use. Families will also be equipped with some simple refrigeration devices. For refrigeration devices such as cold storage, it is very important to select materials with good thermal insulation. Cold storage is a better material selection, and manufacturers need it in the production process of cold storage


ConcepcionSmall installation of cold storageWhat are the advantages in practical applications



Whether the water pump works normally and whether the moldy switch is effective. In case of abnormality, timely handle the overhaul and maintenance of the refrigeration compressor in the cold storage: generally, the refrigeration oil and drying filter shall be replaced 30 times after the operation of the cold storage equipment. Replacement after half a year. Depending on the circumstances.

Refrigerated vehicle planning Kende refrigeration reminds enterprises with the construction needs of logistics refrigerated warehouse project to conduct in-depth communication with the project and refrigerated vehicle planning on warehouse location and actual use needs when determining the final installation construction mode, so as to ensure the smooth circulation of goods in logistics refrigerated warehouse.

Immediate cooling is to install the condenser of the cold storage in the box or building of the cooling equipment, use the volatilization of the refrigerant to immediately cool the air in the air, and use the cold air to cool the objects that need to be cooled. This kind of refrigeration is characterized by faster cooling speed, small heat conduction temperature difference and simple system software, so it is widely used.

Good reputation.The equipment configuration is reasonable and the service life of the quick freezing warehouse is long. The reasonable equipment configuration of the quick freezing warehouse can greatly prolong the service time of the quick freezing warehouse. Some compressors are easy to be damaged when they work at full load for a long time, so we try to use screw parallel units. The great advantage of this unit is that it can turn on all equipment, just like the shift at work, so that the compressor can work and rest in turn.

Polyurethane refrigeration board uses light polyurethane as the internal material of refrigeration board. The advantage of polyurethane is very good heat insulation. The exterior of the cold storage is composed of SII, PVC color steel plate and stainless steel plate. The advantage of this is that it can prevent refrigeration, because the temperature difference inside and outside the board is large,ConcepcionPreservation of fruits in cold storage, ventilating medical products may also emit some odors. Once these odors are stored in a certain quantity which makes refrigeration more energy-saving and improves the working efficiency of refrigeration.

After being stored in the medical cold storage project, they will also have a certain impact on other products. Therefore, we must carry out regular ventilation in the process of daily use, so as to effectively reduce the storage time of products. If the medical cold storage project uses row tube refrigeration, the image of frosting may appear after use for a period of time. If we do not defrost in time, it will also affect the effect of. Therefore, I hope you must pay attention to defrosting.


ConcepcionSmall installation of cold storageWhat are the advantages in practical applications



Stretch perlite: stretch perlite is a kind of granular material with porous layout. The gap in it blocks out the heat. Professional cold storage installation, cold storage installation cold storage construction, fruit fresh-keeping cold storage, medical cold storage, strict testing, quality assurance. Preferential activities are in progress. Welcome to consult. It has a good heat insulation effect. Then, the water vapor in the cold storage is easy to condense and the water absorption of extensional perlite is particularly strong. If it absorbs a lot of water, its nature will be greatly reduced. Therefore, it is necessary to be careful to select extensional perlite as cold storage.

Information recommendation.The combined cold storage does not cool or the cooling effect is poor. Check whether the condenser of the refrigerator is dirty. Whether frost is too thick on the evaporator in the warehouse. Check whether the refrigerant is leaking (apply soapy water to the pipeline connection, and if bubbles are generated, it indicates that the refrigerant is leaking). And ask the combined cold storage engineering personnel to supplement the refrigerant and deal with the leakage. Check whether the sealing of the combined cold storage door is intact and eliminate it. Whether the refrigerator of the combined cold storage works. Whether the parameter setting of the computer controller of the cold storage is correct, and reassemble the cold storage door for installation. Check whether the cooler in the cold storage fails and replace it. Whether there is enough clearance for stacking articles in the warehouse and dredge them.

After the refrigeration system is installed, it shall be beautiful and color. There shall be no cross height inequality of pipelines.

Technical assurance measures for the installation of cold storage: during production in the production workshop, the production shall be carried out in strict accordance with the operation rules specified in ISO9002 quality operation, self inspection and inspection application shall be carried out to ensure that the factory pass rate is, and unqualified products are not allowed to leave the factory.

Concepcion.Install the library body. Generally, the warehouse body can be divided into small warehouse body and large warehouse body. The small warehouse body is basically a combined cold storage assembled with warehouse plate. The large warehouse body is mostly a civil cold storage. The assembled or constructed warehouse body is generally required to be flat,ConcepcionMedical management, compact and solid, without hollow feeling, load-bearing, antifreeze, moisture-proof, etc.

During the cold storage commissioning, special personnel shall be assigned to ensure that the surface of the cold storage plate shall reflect evenly without condensation and cold running; Sealing conditions of joints and holes; Whether the warehouse door and delivery port are not tightly sealed, and timely deal with the problems of insulation and seal failure such as degumming and air leakage.

The door of the combined cold storage is not tightly closed. Please adjust the distance between the hinge on the door and the door lock and the storage body.