SudburyHow much does it cost to install a small cold storageWhat are the benefits of coatings

announcer:hp632HP195506591 release time:2022-02-23 11:07:10

In the cold storage project, the selection of cold storage is related to the overall operation of cold storage in the future. The selection of high-quality cold storage is conducive to the use and maintenance of cold storage. This requires us to inquire more about the warehouse board for cold storage engineering. Before the construction of cold storage project, we should first realize the temperature requirements of cold storage and the importance of cold storage to cold storage. Because the cold storage project has high environmental requirements such as temperature, attention should be paid to the performance and material of the cold storage board when selecting the cold storage board.

During installation, the plates shall be handled with care. Rough operation is strictly prohibited. Burrs shall be removed at the cutting opening to prevent scratching the plate surface and workers.

Sudbury.All lifting bolts of the cooling fan shall be fastened. Professional cold storage installation installation of cold storage, cold storage construction, fruit preservation cold storage, high price, service, on-site settlement, honest management! The holes of bolts and lifting bolts shall be sealed with sealant to prevent cold bridge and air leakage.

Regular oil discharge, descaling and air discharge: when there is a 0.1mm thick oil film in the evaporator coil, in order to maintain the set temperature requirements the evaporation temperature will decrease by 5 ℃ and the power consumption will increase by more than 10; When the scale on the water pipe wall in the condenser reaches 5mm, the condensation temperature will rise by 8 ℃ compared with the original temperature, and the power consumption will increase. When the refrigeration system is mixed with non condensable gas and its partial pressure reaches 0.196mpa, the power consumption will increase by about 1

.The selection of cold storage is very important for cold storage, because cold storage is different from ordinary cold storage. The temperature in cold storage is usually low, and the air temperature, humidity and environmental requirements are relatively high. When selecting cold storage, attention must be paid to the selection of cold storage with better temperature. If the selection of cold storage is not good, the temperature in the cold storage is difficult to, which is easy to cause the deterioration of products in the cold storage, or the refrigeration compressor in the cold storage often works, wasting more resources and increasing the cost.

Fire retardant, flame retardant and high temperature resistant polyurethane is a kind of flame retardant self extinguishing material after adding flame retardant. Its softening point can reach more than 250 ℃, and it will decompose only at higher temperature. In addition, polyurethane forms carbon deposits on the surface of the foam which helps to isolate the foam below. It can effectively prevent flame spread.

During the early operation of the refrigeration unit, carefully observe the oil return of the compressor and keep it clean. If it is found that the oil level is not clean enough or the oil level drops, replace it with new oil in time, so as to avoid bad compressor and reduce the service life of the compressor.


SudburyHow much does it cost to install a small cold storageWhat are the benefits of coatings



We should implement regular maintenance and daily maintenance, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage, large quantity, excellent quality and low price, strong and durable, safe and reliable and maintain the operation rate of the compressor.

When the fresh-keeping warehouse is assembled as a whole, a gap shall be reserved with the wall and roof, the ground or bottom shot must be horizontal, and the construction environment shall be clean.

The foundation of cold storage is affected by low temperature, and the water in the soil is easy to be frozen. Due to the volume of frozen soil, the ground will be broken and the whole building structure will be deformed. If the damage is serious, it may even make the cold storage unusable. Therefore, in addition to the thermal insulation layer, the floor of low-temperature cold storage must be treated under the thermal insulation layer to prevent soil freezing. The bottom plate of the cold storage shall stack a large number of goods and pass through various loading,SudburyQuotation for medical cold storage installation, unloading and transportation machinery and equipment. Therefore, the structure of the cold storage plate shall be firm and have large bearing capacity. In low temperature environment, building structures are vulnerable to. Therefore, the structure of each part of the cold storage and the building materials of the cold storage should have sufficient frost resistance.

production.During the installation of polystyrene storehouse, the Perpendicularity Error of wall plate shall be corrected while the top storehouse plate is installed. The length of the top warehouse plate shall be 10mm shorter than the surface of the wall plate. After the installation of the top warehouse plate, the 10mm gap shall be marked with foaming material to ensure the sealing performance of the warehouse body.

The use of large-scale cold storage is naturally very strict in installation and material selection. Therefore, in the face of the above possible situations, we can strictly screen the insulation board materials of cold storage, which can effectively alleviate or solve the above problems. However, at present, there are many fields using cold storage insulation board, so the details of the use environment should be considered for the wood making of many such products in the market.

For the ground insulation of large cold storage, we can that the ground insulation of medium-sized cold storage is more complex than that of small cold storage and the ground insulation operation of large cold storage with larger warehouse area will be more complex. The common operations are as follows: first lay the ventilation pipe to prevent the ground from freezing drum cracking, then lay the moisture-proof and vapor barrier on the upper and lower sides of the extruded plate then lay the XPS extruded plate (staggered laying is required when laying the extruded plate), then pour the reinforced concrete (generally at least 15cm thick), the XPS extruded plate is also laid according to the warehouse temperature. For example, the XPS extruded plate with thickness of 150 ~ 200mm needs to be laid in the general low-temperature cold storage, while the XPS extruded plate with thickness of 100 ~ 150mm can be laid in the high-temperature cold storage.


SudburyHow much does it cost to install a small cold storageWhat are the benefits of coatings



Where do you need to build the refrigerator, the size of the refrigerator or the storage capacity (size, storage capacity, ton, cubic meter, frame, box); What products are stored in the built cold storage? The actual storage temperature, storage time and setting temperature can be indicated by specific regulations; If your cold storage becomes larger, you need to master your individual storage volume, the temperature of goods in and out of the warehouse, the frequency of opening and closing the door, etc. If this is clear, it is the selection of raw materials, such as refrigeration compressors, refrigeration units, industrial cooling fans / pipe slots, thermal insulation materials, coolers, doors, temperatures and other refrigeration equipment.

Executive standard.Before the acceptance and delivery of the project, the board surface shall be wiped clean. If there is any scratch, it shall be treated. There shall be no obvious scratch on the board surface.

With frequent goods in and out and large throughput, if the supporting steel beam has been installed in the warehouse, the top warehouse plate and the supporting steel beam shall be fixed with pull rivets during the installation of each warehouse plate, and each top warehouse plate shall be riveted in two rows; If the lifting point type is adopted, the installation and construction of the lifting layout shall be realized before the installation and construction of the top silo plate, so as to ensure that each lifting point can be installed at the same time during the installation of the top silo plate; The lifting point shall ensure that there are at least two points along the width direction of each warehouse plate.

Sudbury.The bubble density is 38 kg to 40 kg / m3 per cubic meter, and the steel plate thickness generally needs to be more than 0.4 mm to meet the standard. On the market, the main raw materials of special cold storage board for cold storage project are polyphenylene, polyethylene and polyphenylene grease. The density of thermal insulation material foamed by polyphenylene is thin, and the thermal insulation coefficient is not very high; After a certain ratio of polyethylene,SudburyInstallation and construction of cold storage,SudburyCold storage board installation design, it can foam cold storage insulation materials with appropriate density and good thermal insulation effect, and has high load-bearing capacity; Polyphenylene resin has strong water absorption, but poor heat insulation. Therefore, the polyurethane sandwich board with very good performance belongs to the polyurethane sandwich board. Although it is slightly higher, the polyurethane board has very good thermal insulation performance and does not absorb moisture.

Cork board: cork board can be said to be a relatively primitive kind of cold storage. The thermal conductivity of cork board is relatively low, and it is easy to obtain, so it is not difficult to process, so it is generally used as the insulation board in some ordinary cold storage. If you want to pursue better thermal insulation performance, you have to look at the following materials.

Install the electric control system. The electric control system of the cold storage mainly includes electric controller, electric door, lighting and other electrical equipment in the cold storage. The power supply of the cold storage is required to be stable phase line, and the power supply or backup power supply can be used as required. The circuit shall have reasonable discharge and corresponding protective measures.