NewarkCold storagePrecautions for use

announcer:hp632HP195506591 release time:2022-01-16 22:22:26

Commissioning cold storage. After all parts of the cold storage are installed and connected, the cold storage can be started for cold storage commissioning. According to the needs of customers adjust the value of the cold storage, the cold storage can reach the predetermined temperature, the cooling speed and the operation of the cold storage are normal, and the cold storage can be delivered for use. The cold storage installation unit shall also provide the cold storage user with training on cold storage use and management knowledge, as well as some after-sales training.

Install the library body. Generally, the warehouse body can be divided into small warehouse body and large warehouse body. The small warehouse body is basically a combined cold storage assembled with warehouse plate. The large warehouse body is mostly a civil cold storage. The assembled or constructed warehouse body is generally required to be flat, compact and solid, without hollow feeling, load-bearing, antifreeze, moisture-proof, etc.

Newark.The suction pressure of fresh-keeping storehouse remains unchanged, and when the exhaust pressure increases, the exhaust temperature increases; If the exhaust pressure remains unchanged, when the suction pressure decreases, the exhaust temperature also increases. Both cases are caused by the increase of compression ratio of fresh-keeping warehouse. Too high condensation temperature and exhaust temperature of fresh-keeping warehouse are unfavorable to the operation of compressor, which should be prevented. Too high exhaust temperature will dilute the oil and even carbonize and coke, which will worsen the compressor conditions of the fresh-keeping warehouse.

It is strictly prohibited to place articles with pollution and peculiar smell around the cold storage. The surrounding environment of the cold storage must be cleaned and disinfected regularly every day, and the door of the cold storage must be locked.

.Secondly,NewarkCold storage installation and maintenance, since the cooling of the compressor is not continuous, the multi work operation at night can be selected if possible. When working at night, the external temperature is low, the cooling water temperature is reduced, and the condensation pressure and condensation temperature are reduced. The cooling capacity of the sampling system, coupled with the equal role of the cold storage board, reduces the power operation of the compressor and achieves the purpose of energy saving.

The two sets of connectors between the cold storage shall be wedged tightly, and the two sets of connectors shall be fixed at the upper,NewarkInstallation of medical cold storage, outer and lower sides of the cracks in the cold storage respectively. The lower connector shall be as close as possible, so as to facilitate the use of concrete to cover the connector in the future.

Various construction materials, such as material certificate, test report and stage acceptance record, shall be carried out simultaneously with the project construction, carefully, timely, accurately and comprehensively reflect the whole process of production and construction, and actively cooperate with the owner in design change and technical negotiation.


NewarkCold storagePrecautions for use



Preparation, prepare the project planning of cold storage, and prepare the construction site and construction materials. All kinds of materials for cold storage construction are customized according to the needs of customers. Sort out the construction site that meets the requirements, transport all installation materials to the construction site, check the material quality and model and start the installation of cold storage after confirmation.

After the refrigeration system is installed, it shall be beautiful and color. There shall be no cross height inequality of pipelines.

Regular oil discharge, descaling and air discharge: when there is a 0.1mm thick oil film in the evaporator coil,NewarkInstallation of freezer, in order to maintain the set temperature requirements, the evaporation temperature will decrease by 5 ℃ and the power consumption will increase by more than 10; When the scale on the water pipe wall in the condenser reaches 5mm, the condensation temperature will rise by 8 ℃ compared with the original temperature, and the power consumption will increase. When the refrigeration system is mixed with non condensable gas and its partial pressure reaches 0.196mpa, it can reduce the thickness of building envelope and increase indoor use area under the same thermal insulation requirements.

Disadvantages of single-layer cold storage: large; The surface area of the external enclosure structure of the cold storage is large, so the amount of thermal insulation materials is large, and the dry consumption of cold food is also large; For the low-temperature warehouse, it is impossible to deal with it, which is easy to cause horizontal freezing and swelling.

Improper adjustment or blockage of throttle valve, too large or too small refrigerant flow: improper adjustment or blockage of throttle valve will directly affect the refrigerant flow into evaporator. When the throttle valve is opened too large, the evaporation pressure and evaporation temperature also increase, and the decline rate of warehouse temperature will slow down; At the same time, when the throttle valve is opened too small or blocked, the refrigerant flow will also decrease, the refrigeration capacity of the system will also decrease and the decline rate of warehouse temperature will also slow down.


NewarkCold storagePrecautions for use



The bubble density is 38 kg to 40 kg / m3 per cubic meter, polyethylene and polyphenylene grease. The density of thermal insulation material foamed by polyphenylene is thin the main raw materials of special cold storage board for cold storage project are polyphenylene, and the thermal insulation coefficient is not very high; After a certain ratio of polyethylene, it can foam cold storage insulation materials with appropriate density and good thermal insulation effect, and has high load-bearing capacity; Polyphenylene resin has strong water absorption, but poor heat insulation. Therefore, the polyurethane sandwich board with very good performance belongs to the polyurethane sandwich board. Although it is slightly higher the polyurethane board has very good thermal insulation performance and does not absorb moisture.

Potential development.Another reason is that there are many refrigerants in the system. In this case, find the leakage point first, focus on the connection of each pipeline and valve, repair the found part, and then fill in sufficient refrigerant.

Air tightness test: system air tightness test, also known as leak detection process, is the last link of commissioning. This work can be divided into pressure, vacuum and ammonia filling leak detection stages.

The lights in the warehouse are not on. Please check whether the switch fails and whether the bulb is damaged. Cut off the power supply when installing the lampshade, and pay attention to the waterproof of the lamp.

Newark.The installation of cold storage board is a link of the cold storage installation project. High price cold storage installation of various specifications, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage. Waste merchants, industry, vertical plate and ceiling plate. The installation of storage plates in different directions and precautions are as follows: enter the construction site, verify the construction situation according to the construction drawings, determine the equipment installation position, and then refer to the following specifications.

During the cold storage commissioning, special personnel shall be assigned to ensure that the surface of the cold storage plate shall reflect evenly without condensation and cold running; Sealing conditions of joints and holes; Whether the warehouse door and delivery port are not tightly sealed, and timely deal with the problems of insulation and seal failure such as degumming and air leakage.

How to maintain the refrigeration compressor in the cold storage in order to prolong its service life and reduce the occurrence of faults in the use process. The refrigeration compressor in the cold storage needs regular maintenance. Here we introduce the maintenance of the compressor in the cold storage.