KasugaiCold storage installation, maintenance and installationExperimental method

announcer:hp632HP195506591 release time:2021-12-10 09:52:55

As a coolant, make it evaporate under low pressure and mechanical conditions to absorb the heat in the storage, so as to achieve the purpose of cooling.

The three-dimensional automatic cold storage adopts a computer, which can complete the loading, unloading and stacking in the storage, the control of storage temperature and the operation of refrigeration equipment.

Kasugai.The cold storage construction in the site selection undertakes the circulation of low-temperature goods. Therefore, when selecting the site, priority should be given to the transportation convenience of the cold storage construction site, such as close to roads and railways. At the same time, the location of the cold storage should avoid large pollution sources and direct sunlight, and the construction of the cold storage should have good drainage and ventilation conditions.

Whether the water pump works normally and whether the moldy switch is effective. In case of abnormality, timely handle the overhaul and maintenance of the refrigeration compressor in the cold storage: generally, the refrigeration oil and drying filter shall be replaced 30 times after the operation of the cold storage equipment. Replacement after half a year. Depending on the circumstances.

.It is equipped with temperature compensation to automatically adjust the water temperature. The water temperature of ultrasonic atomization is 15-20 degrees. If our humidifier is connected with the warehouse, there is no temperature compensation, even if

During the early operation of the refrigeration unit carefully observe the oil return of the compressor and keep it clean. If it is found that the oil level is not clean enough or the oil level drops, replace it with new oil in time, so as to avoid bad compressor and reduce the service life of the compressor.

The overall construction achievements of the cold storage project have been put into use, and the service life can reach 10 years.


KasugaiCold storage installation, maintenance and installationExperimental method



Whether there is dirt on the condenser and poor heat dissipation will lead to too high condensation pressure of the refrigerator. In order to protect the compressor, the machine stops running under the action of the pressure controller. When the heat dissipation is good, press the black reset button on the pressure controller, and the machine can automatically resume operation.

The high pressure gauge shall be installed at the opening of the liquid storage tank valve.

Moreover, polyurethane does not produce harmful gas at high temperature.

Quality inspection report.Secondly, since the cooling of the compressor is not continuous, the external temperature is low, the cooling water temperature is reduced, and the condensation pressure and condensation temperature are reduced. The cooling capacity of the sampling system, coupled with the equal role of the cold storage board, stainless steel plate and salted steel. Among them, color steel plate has strong anti rust ability, but stainless steel plate has strong anti rust ability, while salted steel has both beautiful appearance and anti rust ability. According to the layout, it is divided into flat plate and wave plate. The former is flat after the surface material is formed, and the latter is rugged after the surface material is formed. According to the thickness and color of surface materials, the thickness of stainless steel is 0.5mm and 0mm, without color requirements; The thickness of salted steel plate is 0.5mm, without color requirements; The thickness of PE paint baking board is 0.5mm, 0.8mm ivory white, and the thickness of the vertical plate is 160 mm and 100 mm, which is suitable for the insulation conditions of - 25 ℃ ~ - 45 ℃; 100mm storage plate: the thickness of the ceiling plate is 100mm and the thickness of the vertical plate is 110mm which is suitable for the thermal insulation conditions of 0 ℃ ~ - 25 ℃. The thickness of the ceiling plate and the vertical plate of 60mm storage plate is 60mm, which is suitable for the thermal insulation conditions above 0 ℃. In fact, there are many other classification methods of cold storage. Determined by the current processing technology it can be divided into standard plate and non-standard plate according to the width and size range of warehouse plate, including standard plate vertical plate width wa = 900mm, heaven and earth plate width WB = 980mm, vertical angle plate W1 = 790mm, W2 = 840mm, W3 = 740mm and W4 = 880. The dimensions of non-standard plates are different from those of Wa, WB and W4.

Cold storage is mainly used for


KasugaiCold storage installation, maintenance and installationExperimental method



Here we focus on polyurethane. Polyurethane is an ideal cold storage material in the cold storage project. Superior bonding properties make the foam and metal panels form a solid whole, so that no other adhesive materials are needed. When polyurethane is used as a cold storage project, rigid polyurethane foam is formed between the panels of the storehouse panel, and then solidified and pressed to form a multi shape storeboard, because the metal plate can roll out different waveforms, so that the overall rigidity is stronger and the bearing capacity is higher. Polyurethane filler board can meet the firmness and physical requirements of exterior wall and can be used in various cold storage projects. It is technically feasible and cost-effective. Yuanbao refrigeration believes that polyurethane is one of the new cold storage materials with great development prospects in the future. The thermal insulation materials of cold storage engineering should not only have good thermal insulation performance, but also be economical, applicable and environmental friendly. To ensure the smooth progress of our cold storage project, we should not only inquire about the raw materials of the cold storage, but also the types of cold storage. The common cold storage plates mainly include the following types, salted steel plate color zinc steel plate, embossed aluminum plate and 0mm galvanized standard floor plate.

equipment maintenance .First, use a hammer to pad the wood on the polyurethane warehouse board between the two warehouse boards, so as to make the boards closely close to each other. Two sets of connecting pieces shall be wedged between the wall panel and the wall panel, and the two sets of connecting pieces shall be fixed on the upper, outer and lower sides of the gap between the wall panel and the wall panel respectively. The lower connecting piece shall be as close as possible to the lower side so that the post cast concrete can cover the connecting piece. After the gap between the plate and the plate ground is wedged with a connector, it shall be about 3mm wide. If it does not meet the requirements, remove the plate, trim the plate edge, and then reinstall it to make the plate joint meet the requirements. When fixing the adapter, pay attention to fix the two parts of the adapter on the edges of the convex and concave library plates respectively, and fix them with rivets. The spacing of the adapter should be able to tension the two library plates. When wedging the wedge iron, the hammer shall be perpendicular to the wedge iron to prevent damaging the warehouse plate. The ground wedge iron at the upper and lower parts shall be wedged at the same time, and the wedge iron shall be fixed with rivets.

The electrical equipment of the fresh-keeping warehouse equipment shall be prevented from moisture return to prevent it from being caused by power failure.

Airtight construction of quick freezing storehouse: the modified atmosphere fresh-keeping storehouse is developed on the basis of the traditional high-temperature fresh-keeping storehouse, which has the & ldquo; Refrigeration & rdquo; Function, long-term cold storage installation, cold storage installation, cold storage construction, fruit fresh-keeping cold storage, medical cold storage, complete products, excellent quality and favorable price. There are also & ldquo; Air conditioning & rdquo; Function; However, the quick freezing storehouse is not a simple superposition of ordinary high temperature storehouse and air conditioning equipment. In order to adjust the gas composition in the storehouse quickly, it is necessary to ensure that the quick freezing storehouse has good air tightness. This has been confirmed by the theoretical research and a large number of practical experience of quick freezing warehouse.

Kasugai.For water-cooled units, the turbidity of cooling water shall be frequently, the cooling water shall be replaced frequently, and whether the running, emitting, dripping, ventilating medical products may also emit some odors. Once these odors are stored in a certain quantity, they will also have a certain impact on other products. Therefore, we must carry out regular ventilation in the process of daily use, so as to effectively reduce the storage time of products. If the medical cold storage project uses row tube refrigeration, the image of frosting may appear after use for a period of time. If we do not defrost in time, it will also affect the effect of. Therefore, I hope you must pay attention to defrosting.

The ultrasonic town is a patented technology with a shaped energy cover, which increases the effective humidification amount by 50-70% per hour. What are the reasonable aspects of the design of the quick freezing warehouse?