LangkielInstallation price of vegetable cold storageDesign advantages

announcer:hp632HP195506591 release time:2022-02-22 14:07:09

and the height width ratio of floor drain water seal shall not be less than 50mm. The elevator shaft, electronic pit and other places convenient for drainage shall be provided with drainage and equipment to avoid backflow of water.

The type of cold storage to be built in the type of cold storage should be determined according to the type of circulating goods. For example, the cold storage that only circulates vegetables can only build a fresh-keeping cold storage, while the cold storage with refrigeration + freezing will be built if there are many types of circulating goods and great difference in storage temperature. As for the size of the cold storage, it should be determined according to the type, quantity, frequency, cycle, whether to use shelf stacking and so on. For example, for fruits and vegetables packed in cartons, the storage capacity of 280-330kg per cubic meter can be referred to, and the size of cold storage construction can be estimated in combination with the storage capacity rate of about 0.5-0.6.

Langkiel.If the refrigerator has been used for more than months, or the high / low voltage switch often fails, or the refrigeration capacity is reduced, please arrange staff to clean the condenser. If the ultra-thin light box is repaired according to the above instructions for many times, and the refrigerator fault still sounds for a long time, please ask the maintenance personnel of the refrigerator to repair it.

All wiring shall be neat. All switches and keys shall be opened and closed sensitively, reliably and accurately. Special connectors shall be used for wiring and power protection shall be provided for the box and each power branch.

.Another reason is that there are many refrigerants in the system. In this case, find the leakage point first focus on the connection of each pipeline and valve, repair the found part, and then fill in sufficient refrigerant.

The temperature and humidity in the warehouse shall be kept uniform without movement; Try to finish the food in the warehouse at one time.

In order to ensure the safety of construction and cold storage operation, the span between the top storage plate supports (lifting points) shall comply with the following provisions: the polystyrene top storage plate (100mm thick) has a very large span of 3M, and the polyurethane top storage plate (100mm thick) has a span of 5m.


LangkielInstallation price of vegetable cold storageDesign advantages



General quick-frozen warehouses are mostly cooled by refrigeration mechanism with low gasification temperature (ammonia or Freon)

Measure the winding resistance of the compressor and the insulation of the motor.

The overall construction achievements of the cold storage project have been put into use, the thermal conductivity is only 0.018 ~ 0.024w / (m.k), such as material certificate test report and stage acceptance record, shall be carried out simultaneously with the project construction, carefully, timely, accurately and comprehensively reflect the whole process of production and construction, and actively cooperate with the owner in design change and technical negotiation.

The equipment is built according to the application requirements of low-temperature distribution. It is reflected in the following 6 points: a low-temperature hall, a closed platform, an electric sliding refrigerated door, an anti-collision flexible seal, and a platform height conditioning equipment (lifting channel) are built to complete & ldquo; Door to door & rdquo; Type loading and unloading operation has become a symbol of modern cold storage.


LangkielInstallation price of vegetable cold storageDesign advantages



Fire retardant, flame retardant and high temperature resistant polyurethane is a kind of flame retardant self extinguishing material after adding flame retardant. Its softening point can reach more than 250 ℃, and it will decompose only at higher temperature. In addition, polyurethane forms carbon deposits on the surface of the foam, which helps to isolate the foam below. It can effectively prevent flame spread.

Packaging strategy.The three-dimensional automatic cold storage adopts a computer, which can complete the loading, unloading and stacking in the storage, the control of storage temperature and the operation of refrigeration equipment.

Whether it is a fruit fresh-keeping warehouse or other cold storage, there are many details to pay attention to in the transformation of the cold storage. If other small items are not done well, it will bring a lot of trouble to the later use, such as high energy consumption and small problems.

The common phenomenon of quick freezing storehouse is that the temperature of quick freezing storehouse can't drop down or drops slowly. Now, a simple analysis is made on the reasons for the slow drop of temperature: the cold capacity loss of quick freezing storehouse is large due to poor thermal insulation or sealing performance; the poor thermal insulation performance is due to insufficient thickness of thermal insulation layer of pipeline and warehouse thermal insulation wall, resulting in poor thermal insulation and thermal insulation effect, It is mainly caused by improper selection of insulation layer thickness in design or poor quality of insulation materials in construction.

Langkiel.The equipment that needs to be installed in the warehouse and put into the warehouse shall be installed in place or placed in an appropriate position in the warehouse; The wall warehouse board shall be installed from the corner of the warehouse body, and the professional cold warehouse shall be installed. The cold warehouse shall be installed. The cold warehouse shall be constructed. The fruit fresh-keeping cold warehouse and medical cold warehouse shall have high pressure rating, good waterproof performance, fire and high temperature resistance, strong overload capacity, corrosion resistance, radiation protection and long service life. The corner shall be temporarily fixed with 0.5 color plate angle steel; When installing each wall panel, evenly apply two layers of foaming material on the joint surface of male and female groove, and apply one layer of foaming material when installing polystyrene wall panel. The blanking shall be uniform and continuous; After the wallboard is installed in place, pull rivets at the lap joint of the internal and external steel plates of the two wallboards for connection and fixation and the rivet spacing in the warehouse should be 300mm; When connecting the library plate in the form of eccentric hook connection, the eccentric hook shall be loosened once before installation to ensure reliable locking during installation.

Floor insulation of small cold storage the structure of small cold storage is usually called surface, that is, the top, wall and ground are made of color steel plate / stainless steel with appropriate thickness of polyurethane and other insulation materials, because the loading and unloading of small cold storage is often handled manually rather than forklift. Of course, if the height of the warehouse is high and the forklift is required for warehousing, loading and unloading, the insulation board is not recommended for ground insulation, but the ground needs to be insulated separately like the ground insulation sample of medium-sized cold storage.

There are many kinds of cold storage. According to the material, it can be divided into color steel plate, stainless steel plate and salted steel. Among them, color steel plate has strong anti rust ability, while salted steel has both beautiful appearance and anti rust ability. According to the layout, it is divided into flat plate and wave plate. The former is flat after the surface material is formed, and the latter is rugged after the surface material is formed. According to the thickness and color of surface materials, the thickness of stainless steel is 0.5mm and 0mm, without color requirements; The thickness of salted steel plate is 0.5mm, without color requirements; The thickness of PE paint baking board is 0.5mm, 0.8mm ivory white, titanium white and white gray. The most important thing for the cold storage is the applicable temperature of the cold storage. It is divided according to the insulation thickness of the storage plate. The thickness of the sky floor of the 150 mm storage plate is 150 mm, and the thickness of the vertical plate is 160 mm and 100 mm, which is suitable for the insulation conditions of - 25 ℃ ~ - 45 ℃; 100mm storage plate: the thickness of the ceiling plate is 100mm and the thickness of the vertical plate is 110mm, which is suitable for the thermal insulation conditions of 0 ℃ ~ - 25 ℃. The thickness of the ceiling plate and the vertical plate of 60mm storage plate is 60mm, which is suitable for the thermal insulation conditions above 0 ℃. In fact, there are many other classification methods of cold storage. Determined by the current processing technology it can be divided into standard plate and non-standard plate according to the width and size range of warehouse plate, including standard plate vertical plate width wa = 900mm, heaven and earth plate width WB = 980mm, vertical angle plate W1 = 790mm, W2 = 840mm, W3 = 740mm and W4 = 880. The dimensions of non-standard plates are different from those of Wa