West-EndInstallation of small freezerStable operation of the industry

announcer:hp632HP195506591 release time:2022-02-14 10:20:06

The insulation board of the cold storage adopts polyurethane double-sided color steel plate. The main effect of this cold storage insulation board is good sealing performance, insulation effect and moisture-proof effect,West-EndInstallation of large and medium-sized cold storage, so as to ensure the refrigeration effect of the cold storage. The electric cold storage door is adopted for the cold storage door, and the cold storage management personnel can timely and effectively open and close the door when entering and leaving, so as to avoid the loss of refrigeration capacity of the cold storage.

1 - precautions for floor installation of cold storage: the floor shall be installed flat, the uneven part shall be leveled with materials, and the locking hook between the plates shall be locked to ensure that the warehouse surface is flat without hollow feeling. (note that if this drainage system is installed outdoors in the north, the drainage pipe shall be insulated).

West-End.The warehouse shall be reasonably divided and set with relevant signs to facilitate the storage, transportation and management of goods in the warehouse.

The quick-frozen warehouse is easy to load and unload. All the plates and walls of the quick-frozen warehouse are produced by molds. You can choose tens of millions of products. Professional cold storage installation, installation of cold storage cold storage construction, fruit preservation cold storage,West-EndInstallation price of cold storage, medical cold storage and transaction safety are guaranteed. Through internal concave convex groove connection, loading, unloading and handling are convenient. The installation period is short. Small and medium-sized cold storage can be delivered in 2-5 days, The library body can be combined, separated or increased or decreased according to the needs of users.

.The foundation of cold storage is affected by low temperature, and the water in the soil is easy to be frozen. Due to the volume of frozen soil, the ground will be broken and the whole building structure will be deformed. If the damage is serious, in addition to the thermal insulation layer, the floor of low-temperature cold storage must be treated under the thermal insulation layer to prevent soil freezing. The bottom plate of the cold storage shall stack a large number of goods and pass through various loading, unloading and transportation machinery and equipment. Therefore, especially in the process of periodic freezing and thawing cycle, building structures are vulnerable to. Therefore, the structure of each part of the cold storage and the building materials of the cold storage should have sufficient frost resistance.

Other aspects: in the design process of food cold storage, it is also necessary to consider the cooperation between the cold storage and on-site fire fighting, ventilation, water and electricity systems. It should meet the requirements of safety, science and environmental protection. When designing and installing the cold storage, the drainage problem must be considered, and the following 8 points should be paid attention to during redesign and installation.

Installation of refrigeration equipment. The refrigeration system of the cold storage includes evaporator and units outside the cold storage. All equipment shall be installed in accordance with the construction specifications, and corresponding protection measures shall be taken for the installed equipment.


West-EndInstallation of small freezerStable operation of the industry



Danfoss thermal valve is adopted for the thermal valve of the cold storage, with guaranteed quality; Due to the high temperature requirements of the cold storage and the high degree of automation and regulation of the temperature, does not need special people to operate, and can be remotely controlled. When the temperature exceeds the specified range, it will automatically alarm, which is of great significance to the proper preservation of the cold storage.

In use, the fresh-keeping warehouse must be maintained on time and scientifically. No matter how good the equipment is without scientific use and maintenance, its service life and effect will be discounted. Therefore, the fresh-keeping warehouse also needs to be maintained regularly every year, so as to ensure its stable operation.

Large space rate of quick-frozen warehouse: for quick-frozen warehouses of the same size, reasonable design schemes store more goods than unreasonable ones. For the fixed size quick freezing warehouse, we reasonably designed to expand the original storage capacity of 300 boxes to 400 boxes, which increases the space a lot.

Create brilliance.There are two reasons: the refrigerant charge is insufficient. At this time, just add enough refrigerant.

Insufficient refrigeration dose and capacity in the system: insufficient refrigerant circulation is the main reason

Reasonable space: the power consumption of the cold storage is calculated according to the cold consumption of the cold storage, which usually includes two parts: the cold consumption during cargo cooling and refrigeration; It is the cooling consumption of the refrigeration room itself and operation management.


West-EndInstallation of small freezerStable operation of the industry



The selection of equipment for the construction of equipment cold storage is closely related to the size, type and budget of the cold storage.

Excellent service.With the increasing use of cold storage cold storage board, as an important structure of cold storage, is also increasing. Because cold storage is different from other ordinary cold storage, it is important to the installation environment and temperature. Therefore, some small problems may be ignored during installation. According to the following understanding.

The maintenance of electrical equipment in the wholesale of fresh-keeping warehouse equipment is actually operated by welders or staff who understand the knowledge of power consumption. The switching power supply must be disconnected during maintenance.

During the use of the goods yard medical cold storage project, the stored goods must be in strict accordance with the relevant regulations. The goods should have a certain distance from the ground and wall of the cold storage. When stacking, the distance between the goods and the goods must be cm. At the same time, the distance between the goods and the cold fan should also be 100 cm. No goods can be stored within this range, This is also an important content in the use of medical cold storage engineering.

West-End.Danfoss thermal valve is adopted for the thermal valve of the cold storage, with guaranteed quality; Due to the high temperature requirements of the cold storage and the high degree of automation and regulation of the temperature, the temperature system of the cold storage adopts microcomputer full-automatic, does not need special people to operate, and can be remotely controlled. When the temperature exceeds the specified range, it will automatically alarm,West-EndWhich is a good cold storage installation, which is of great significance to the proper preservation of the cold storage.

Technical assurance measures for the installation of cold storage: during production in the production workshop, the production shall be carried out in strict accordance with the operation rules specified in ISO9002 quality operation, self inspection and inspection application shall be carried out to ensure that the factory pass rate is, and unqualified products are not allowed to leave the factory.

Refrigeration system: refrigeration system is the core part of cold storage design. It is the key to determine the economy environmental protection and performance of cold storage.