NeftaInstallation of combined cold storageWhat are the specific hazards

announcer:hp632HP195506591 release time:2021-12-28 20:51:40

Step of cold storage design: define the volume of the cold storage warehouse. The size of the cold storage should be based on the design of a large number of agricultural products to be stored for a long time. This volume is calculated based on the essential volume of stored goods accumulated in the cold storage, plus the row to row corridors the indoor space between the pile and the wall, the ceiling and the gap of the packaging house. After the volume of the cold storage is determined, the length and height width ratio of the cold storage shall be determined. Necessary auxiliary engineering buildings and equipment shall also be considered in the design of cold storage such as working intermediate, packaging and combing room, special tool warehouse, loading and unloading platform, etc.

During the use of the goods yard medical cold storage project, the stored goods must be in strict accordance with the relevant regulations. The goods should have a certain distance from the ground and wall of the cold storage. When stacking, the distance between the goods and the cold fan should also be 100 cm. No goods can be stored within this range, This is also an important content in the use of medical cold storage engineering.

Nefta.Frozen and refrigerated storage begins to shift to shelf and pallet storage in accordance with & amp; amp; amp; ldquo; FIFO & amp; amp; amp; rdquo; This is conducive to improving the quality of commodity storage and reducing losses.

The cooking materials and foods refrigerated in the quick-frozen warehouse contain a certain amount of fat, protein and starch. The existence of these nutrients will make molds and bacteria multiply and grow in large numbers. In order to do a good job in the hygienic management of cold areas and ensure the refrigeration quality of food and cooking raw materials, it is necessary to carry out the hygienic disinfection of cold areas regularly.

.The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration, it shall be able to ensure the reliable power supply of the exhaust fan. The overload protection of the exhaust fan should be applied to the signal alarm system without directly stopping the exhaust fan. The button box of the exhaust fan shall be concealed in the wall outside the ammonia compressor room.

The quick-frozen warehouse is easy to load and unload. All the plates and walls of the quick-frozen warehouse are produced by molds. You can choose tens of millions of products. Professional cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage and transaction safety are guaranteed. Through internal concave convex groove connection, loading, unloading and handling are convenient. The installation period is short. Small and medium-sized cold storage can be delivered in 2-5 days, The library body can be combined, separated or increased or decreased according to the needs of users.

The construction structure of structural cold storage can be brick concrete structure or steel structure, which can be determined according to their own budget and actual needs. At present, most cold storages are constructed with single-layer steel structure and are equipped with combined thermal insulation storage body, refrigeration system, system, pipeline system, the production shall be carried out in strict accordance with the operation rules specified in ISO9002 quality operation, self inspection and inspection application shall be carried out to ensure that the factory pass rate is, and unqualified products are not allowed to leave the factory.

The three-dimensional automatic cold storage adopts computer, which can complete the loading and unloading, stacking, storage temperature and refrigeration equipment operation of the cold storage.

The medical cold storage has been widely used in the industry. For the use of the medical cold storage project, we must combine the performance of the product and store it according to the temperature and humidity required by the product. The automatic temperature box also needs to be used outside the product cold storage. At the same time, the management personnel must be familiar with the operation steps of the medical cold storage project.

superior quality.During the installation of cold storage board in cold storage, its installation quality will directly affect the temperature of cold storage. As an important structure used in the cold storage, the cold storage board should pay attention to the details of its installation, find out the problems that are easy to be ignored, and avoid the wrong installation, which will affect the use of the cold storage or the whole installation process, so as to waste resources and increase the cost.

2 - Installation of the vertical plate of the cold storage: select the angle first according to the site conditions and locate it (i.e. lock the vertical plate and the floor) to extend to both sides at this angle. Only lock the vertical plate and the vertical plate, and locate it when it meets the vertical angle. Put the beautiful plate in a conspicuous place. When installing it on the side of the evaporator, make the drainage pipe in advance, and make U-bend and silica gel outside the storage.

Compression refrigerator is commonly used, which is mainly composed of compressor, condenser, throttle valve and evaporation pipe. According to the way of evaporation pipe device, it will directly absorb the heat in the warehouse and cool down.


NeftaInstallation of combined cold storageWhat are the specific hazards



The insulation board of the cold storage adopts polyurethane double-sided color steel plate. The main effect of this cold storage insulation board is good sealing performance, insulation effect and moisture-proof effect, so as to ensure the refrigeration effect of the cold storage. The electric cold storage door is adopted for the cold storage door, and the cold storage management personnel can timely and effectively open and close the door when entering and leaving, so as to avoid the loss of refrigeration capacity of the cold storage.

Quality assurance.The medical cold storage has been widely used in the industry. For the use of the medical cold storage project, we must combine the performance of the product and store it according to the temperature and humidity required by the product. The automatic temperature box also needs to be used outside the product cold storage. At the same time the management personnel must be familiar with the operation steps of the medical cold storage project.

When installing and splicing the storeboard in the fresh-keeping storehouse, it needs to be tightly sewn to ensure the tightness; The fresh-keeping storehouse will discharge water during operation, and the drainage pipe should be installed in a place that can circulate; An anti-collision barrier shall be installed around the door of the fresh-keeping storehouse to prevent the door from being damaged by impact. To play an eye-catching role, the fresh-keeping storehouse shall be equipped with emergency lights, alarm devices and safety channels to facilitate self rescue or alarm for help in case of emergencies.

The structure of contemporary cold storage is in the development trend of prefabricated building cold storage. It is made into prefabricated components of cold storage including steam barrier and heat insulation plate to ensure on-site assembly. Its advantage is that the project construction is convenient, rapid and movable, but the project cost is relatively high.

Nefta.In order to ensure the safety of construction and cold storage operation, the span between the top storage plate supports (lifting points) shall comply with the following provisions: the polystyrene top storage plate (100mm thick) has a very large span of 3M, and the polyurethane top storage plate (100mm thick) has a span of 5m.

Suggestions on the quantity of polyurethane cold storage insulation materials: cold storage investment is a long-term and profitable investment. A high quantity of hair can certainly reduce the initial investment, but it is necessary to grasp a certain limit and comprehensively consider the long-term energy consumption and initial investment, because the insulation effect of polyurethane cold storage insulation materials has a parabolic linear correlation with its bulk weight; A large number of studies have shown that the foam bulk density has better thermal insulation performance at 33~35 kg / cubic meter. Therefore, it is usually recommended that the number of thermostat refrigeratory outlets should be 22~23 square / ton.

For the flushing (thawing) drainage pipe in the cold room with different temperature, an exhaust valve equipment shall be set before connecting the flushing (thawing) drainage pipe.