the frost free quick freezing method is adopted

Features of quick freezing warehouse: the quick freezing technology is advanced, and the automatic frost is adopted. The method can only be used by microcomputer. The refrigeration system adopts green refrigerant, so as to make the boards closely close to each other. Two sets of connecting pieces shall be wedged between the wall panel and the wall panel, and the two sets of connecting pieces shall be fixed on the upper outer and lower sides of the gap between the wall panel and the wall panel respectively. The lower connecting piece shall be as close as possible to the lower side, so that the post cast concrete can cover the connecting piece. After the gap between the plate and the plate ground is wedged with a connector, it shall be about 3mm wide. If it does not meet the requirements, remove the plate, trim the plate edge, and then reinstall it to make the plate joint meet the requirements. When fixing the adapter, pay attention to fix the two parts of the adapter on the edges of the convex and concave library plates respectively, and fix them with rivets. The spacing of the adapter should be able to tension the two library plates. When wedging the wedge iron the hammer shall be perpendicular to the wedge iron to prevent damaging the warehouse plate. The ground wedge iron at the upper and lower parts shall be wedged at the same time, and the wedge iron shall be fixed with rivets.

The-Caymans.After evacuation, fill the refrigerant into the liquid storage to 70% of the standard filling volume & mdash; 80% by weight, then run the compressor and add gas from low pressure to sufficient volume.

In fact, there are some unique installation skills when installing the cold storage? The cold storage installed according to these skills is often short in both effect and quality, and the specific installation skills of the cold storage will also make some relatively detailed introduction for you in the following article. When installing the cold storage, you should install it from the corner first. Later, according to the height of the cold storage, make a hole in the middle of the insulation board behind the angle iron parts

.Fault phenomenon: fan motor overload, fan deformation; Fan motor fault; Fan motor thermal relay fault (aging); Loose wiring; Cooler blocked; Large exhaust resistance. Fault phenomenon of cold storage: the dryer does not operate, the compressor line is disconnected, the fuse is blown, the thermal relay acts, the high-voltage switch acts, the compressor is locked, the line is falsely connected or loose. Fault phenomenon: it stops in a short time after the drying motor, and the environment

Panel types of quick freezing warehouse: color plastic steel plate, salted steel plate, stainless steel plate, embossed aluminum, etc.

In order to maintain a constant low temperature in the cold storage, attention should be paid to the installation of cold storage panels in Guizhou: the floor, wall and flat roof of the cold storage are laid with a certain thickness of thermal insulation materials to reduce the incoming heat from the outside. In order to reduce the absorption of solar radiation, the surface of the external wall of the cold storage is painted white or light color. Therefore, cold storage building is different from general industrial and civil buildings, and has its unique structure. Cold storage buildings should prevent the entry of air and the diffusion of water vapor.


The-CaymansRefrigeration equipment of medical cold storageApplication categories and installation methods



The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration, it shall be able to ensure the reliable power supply of the exhaust fan. The overload protection of the exhaust fan should be applied to the signal alarm system without directly stopping the exhaust fan. The button box of the exhaust fan shall be concealed in the wall outside the ammonia compressor room.

The location of fresh-keeping warehouse installation shall be in a stable and convenient place; (if it is a local fruit farmer it should be installed near the fruit source)

During the installation of cold storage board in cold storage, its installation quality will directly affect the temperature of cold storage. As an important structure used in the cold storage, find out the problems that are easy to be ignored, and avoid the wrong installation, which will affect the use of the cold storage or the whole installation process, so as to waste resources and increase the cost.

target.General quick-frozen warehouses are mostly cooled by refrigeration mechanisms, and those with very low gasification temperature are used as coolant to evaporate under low pressure and mechanical conditions, so as to absorb the heat in the warehouse, so as to achieve the purpose of cooling and reduction.

During the installation of polystyrene storehouse, the Perpendicularity Error of wall plate shall be corrected while the top storehouse plate is installed. The length of the top warehouse plate shall be 10mm shorter than the surface of the wall plate. After the installation of the top warehouse plate, the 10mm gap shall be marked with foaming material to ensure the sealing performance of the warehouse body.

Reasonably adjust the cold storage evaporator and defrost in time: Generally speaking, every 1 ℃ increase in the evaporation temperature of the cold storage can save energy by 2 ~ 5. Therefore, on the premise of meeting the refrigeration process of the product the liquid supply can be adjusted to increase the evaporation temperature as much as possible.


The-CaymansRefrigeration equipment of medical cold storageApplication categories and installation methods



The physical properties of polyurethane insulation board are relatively good, which can meet different needs. The polyurethane insulation board is also strict in the selection of materials. It is a special product manufacturing enterprise integrating R & D, and service. It has long been specialized in cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage and medical cold storage. It improves the overall performance of the polyurethane insulation board and enables the polyurethane insulation board to work for a long time, Polyurethane insulation board has also become one of the main exterior wall materials.

Workshop cost.The assembled cold storage body often adopts double-sided color steel plate of polyurethane thermal insulation material, which has excellent thermal insulation performance, storage and circulation effect and reduces operation energy consumption. Of course, more important is the choice of refrigeration system. For example, at present, the refrigeration system of fluorine refrigerant is still the mainstream, but when selecting the type and power of cooling equipment, it is necessary to calculate the data for the installation of cold storage, and then make a high-quality choice.

The fresh-keeping storehouse is generally composed of maintenance structure and refrigeration equipment. It is mostly cooled by compressor, and the gasification temperature is very low as coolant, so that it can evaporate under low pressure and mechanical conditions, and absorb the heat in the storage warehouse, so as to achieve

Step of cold storage design: define the volume of the cold storage warehouse. The size of the cold storage should be based on the design of a large number of agricultural products to be stored for a long time. This volume is calculated based on the essential volume of stored goods accumulated in the cold storage, plus the row to row corridors, the indoor space between the pile and the wall, the ceiling and the gap of the packaging house. After the volume of the cold storage is determined, the length and height width ratio of the cold storage shall be determined. Necessary auxiliary engineering buildings and equipment shall also be considered in the design of cold storage, such as working intermediate, packaging and combing room, special tool warehouse, etc.

The-Caymans.At ordinary times, users should check the sealing degree of the gap of the cold storage, and notify the cold storage for maintenance in time if damaged parts are found.

Grasp the key points. Now let's analyze the production and use requirements of the cold storage. There is no condensation in the cold storage. Condensation in the cold storage or in the insulation layer is harmful. During the drying process of the new wall or under winter conditions, when the water vapor with high indoor temperature migrates outdoors, it is impossible to condense in the wall due to the obstruction of the cold storage.

During production in the production workshop, the unit weight of Pu warehouse board shall not be less than the unit weight required by the project, not less than 40 & plusmn; 2kg/m3.