FredricktonFrozen preservation of vegetablesProcessing new common problems and corresponding solutions

announcer:hp632HP195506591 release time:2022-03-09 21:24:27

just add enough refrigerant.

For water-cooled units

There are two reasons: the refrigerant charge is insufficient. At this time, the turbidity of cooling water shall be frequently, the cooling water shall be replaced frequently, and whether the running, emitting dripping, leakage and other conditions of the water supply system exist.

Fredrickton.If the refrigerator has been used for more than months, or the high / low voltage switch often fails, or the refrigeration capacity is reduced, please arrange staff to clean the condenser. If the ultra-thin light box is repaired according to the above instructions for many times, and the refrigerator fault still sounds for a long time, please ask the maintenance personnel of the refrigerator to repair it.

Whether the parameters of refrigeration equipment are consistent. When the cold storage leaves the factory, the temperature and temperature difference parameters of the cold storage shall be customized according to the user's requirements. After understanding the technical parameters of the cold storage, set the parameters on the refrigerator. During use, the air humidity is high and the defrosting interval is long. The common cold storage boards of cold storage include 100mm, 120mm, 150mm, 175mm and 200mm polyurethane thermal insulation boards, color steel tiles, stainless steel plates, salt thick steel plates, embossed aluminum plates, polyurethane spraying, etc. on both sides or single and double sides, more general color steel tiles are produced and processed into hidden grooves, which have light weight, high compressive strength,FredricktonCold storage installation Telephone, good fire resistance, corrosion resistance and aging resistance, The cold storage board is simple and convenient to assemble, and is a wide range of raw materials selected for the heat insulation and heat preservation of the cold storage. The cost of stainless steel plate and salt plate increases,FredricktonCold storage installation materials, and it is also easy to deform and damage the appearance.

.Suggestions on the quantity of polyurethane cold storage insulation materials: cold storage investment is a long-term and profitable investment. A high quantity of hair can certainly reduce the initial investment, but it is necessary to grasp a certain limit and comprehensively consider the long-term energy consumption and initial investment, because the insulation effect of polyurethane cold storage insulation materials has a parabolic linear correlation with its bulk weight; A large number of studies have shown that the foam bulk density has better thermal insulation performance at 33~35 kg / cubic meter. Therefore, it is usually recommended that the number of thermostat refrigeratory outlets should be 22~23 square / ton.

The floor of the cold storage shall be kept as close as possible during use

Fault phenomenon: high current or tripping during unit startup, and problems of user air switch; Input voltage is too low; The star angle conversion interval is too short (it should be 10 ~ 12 seconds); Hydraulic cylinder failure (no reset); Intake valve failure (too large opening or stuck); Loose wiring; Host failure; Main motor fault; 1TR time relay is broken (relay unit).


FredricktonFrozen preservation of vegetablesProcessing new common problems and corresponding solutions



2 - cold storage

Ice cubes are always available in the cold storage. For small cold storage, the cost of using standby power supply or generator set is too high and the cost performance is low. In this case, some ice cubes must be always available in the cold storage. In case of power failure or refrigeration equipment failure, ice cubes can be used to maintain the temperature in the cold storage.

Disadvantages of single-layer cold storage: large; The surface area of the external enclosure structure of the cold storage is large, so the amount of thermal insulation materials is large, and the dry consumption of cold food is also large; For the low-temperature warehouse, the floor anti freezing treatment requires a large amount of work. When the cold storage is built at the water level, it is impossible to deal with it, which is easy to cause horizontal freezing and swelling.

original.Suggestions on the quantity of polyurethane cold storage insulation materials: cold storage investment is a long-term and profitable investment. A high quantity of hair can certainly reduce the initial investment, because the insulation effect of polyurethane cold storage insulation materials has a parabolic linear correlation with its bulk weight; A large number of studies have shown that the foam bulk density has better thermal insulation performance at 33~35 kg / cubic meter. Therefore, it is usually recommended that the number of thermostat refrigeratory outlets should be 22~23 square / ton.

It is strictly prohibited to place articles with pollution and peculiar smell around the cold storage. The surrounding environment of the cold storage must be cleaned and disinfected regularly every day and the door of the cold storage must be locked.

In the low temperature environment, especially in the periodic freezing and thawing cycle, the building structure is also vulnerable to. Therefore, make it evaporate under low pressure and mechanical conditions to absorb the heat in the storage so as to achieve the purpose of cooling.

agent.During the installation of cold storage board in cold storage, its installation quality will directly affect the temperature of cold storage. As an important structure used in the cold storage, the cold storage board should pay attention to the details of its installation, find out the problems that are easy to be ignored, and avoid the wrong installation, which will affect the use of the cold storage or the whole installation process so as to waste resources and increase the cost.

Ammonia filling leak test: ammonia filling leak detection can be carried out after system blowdown and pressure leak test. The purpose is to improve the air tightness of the system and lay a good foundation for the work of ammonia filling and thermal insulation materials of the system. After air leakage detection, some obvious leakage points can be found. However, due to the poor air permeability, the leakage points blocked by dirt along the tiny sand holes are not easy to be detected. Therefore, ammonia must be filled. In addition to good permeability, ammonia also has odor and is easy to be found, At the same time, phenolphthalein test paper can be used for leak detection because it is rose red in the presence of ammonia.

Cold storage board, compressor, and other components in the cold storage can reasonably adjust the evaporation and condensation temperature, so as to improve the reduction of power consumption and reduce the production cost. Professional cold storage installation, installation of cold storage, cold storage construction,FredricktonFresh keeping cold storage vegetables and fruits, medical cold storage, professional, timely supply and high cost performance. It has become the preferred brand for many wire products. Welcome to buy! Save more resources.

Fredrickton.The installation of top warehouse plate should be carried out alternately with the installation of wall plate, the end steel sheet at the overlap with the wall plate shall be disconnected for 50mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, and the rivet spacing shall be 300mm; According to the design drawings, if there are supporting beams, columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, column, support steel frame, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.

The combined cold storage does not cool or the cooling effect is poor. Check whether the condenser of the refrigerator is dirty. Whether frost is too thick on the evaporator in the warehouse. Check whether the refrigerant is leaking (apply soapy water to the pipeline connection, and if bubbles are generated, it indicates that the refrigerant is leaking). And ask the combined cold storage engineering personnel to supplement the refrigerant and deal with the leakage. Check whether the sealing of the combined cold storage door is intact and eliminate it. Whether the refrigerator of the combined cold storage works. Whether the parameter setting of the computer controller of the cold storage is correct, and reassemble the cold storage door for installation. Check whether the cooler in the cold storage fails and replace it. Whether there is enough clearance for stacking articles in the warehouse and dredge them.

For water-cooled units, the turbidity of cooling water shall be frequently, the cooling water shall be replaced frequently, and whether the running, emitting, dripping, leakage and other conditions of the water supply system exist.