BiuMedical refrigeration cold storageStrong compiling ability

announcer:hp632HP195506591 release time:2021-12-26 17:27:12

Insufficient refrigeration dose and capacity in the system: insufficient refrigerant circulation is the main reason

Whether the water pump works normally and whether the moldy switch is effective. In case of abnormality, timely handle the overhaul and maintenance of the refrigeration compressor in the cold storage: generally, the refrigeration oil and drying filter shall be replaced 30 times after the operation of the cold storage equipment. Replacement after half a year. Depending on the circumstances.

Biu.The set values of various protective devices of the unit have been adjusted by the factory. Users are not allowed to change them at will.

Improper adjustment or blockage of throttle valve, too large or too small refrigerant flow: improper adjustment or blockage of throttle valve will directly affect the refrigerant flow into evaporator. When the throttle valve is opened too large, the refrigerant flow is too large, the evaporation pressure and evaporation temperature also increase and the decline rate of warehouse temperature will slow down; At the same time, when the throttle valve is opened too small or blocked, the refrigeration capacity of the system will also decrease, and the decline rate of warehouse temperature will also slow down.

.The structure of contemporary cold storage is in the development trend of prefabricated building cold storage. It is made into prefabricated components of cold storage including steam barrier and heat insulation plate to ensure on-site assembly. Its advantage is that the project construction is convenient, but the project cost is relatively high.

Frozen and refrigerated storage began to change to shelf and pallet storage to complete the goods according to & ldquo; First in first out & rdquo; It is conducive to improve the quality of commodity storage and reduce loss.

The construction of small cold storage is widely used in life, such as food industry, manufacturing industry, etc. since cold storage is so widely used, do you know cold storage? Especially the construction process and steps of cold storage. Understanding the construction process and steps of cold storage is helpful for all links of cold storage maintenance.


BiuMedical refrigeration cold storageStrong compiling ability



8. This shows the importance of regular oil discharge, descaling and air discharge in the refrigeration system of cold storage.

OK, it has little impact on the storage temperature, but it has high labor intensity, incomplete defrosting and limitations.

The quantity is large, and a special tally room (area) is set according to the needs of production and operation. The temperature of the tally area is usually controlled at 0 ~ + 7 ℃.

How much does it cost?.Disadvantages of multi-layer cold storage: the vertical transportation volume of the warehouse is large, and the goods in and out and operation management are not as convenient as single-layer cold storage; With the development of the floor load capacity, the floor area ratio of each cold room is low; When the multi-storey cold storage is built on the foundation with poor ground resistance, the foundation construction is complex. High cost; When prefabricated components are used, large construction equipment is required and the construction period is long.

There is a slight sag on the cold insulation board to prevent damage to the cold storage. When standing on the wall, some soft materials should be laid on the floor of the cold storage tank.

During the installation of polystyrene storehouse, the Perpendicularity Error of wall plate shall be corrected while the top storehouse plate is installed. The length of the top warehouse plate shall be 10mm shorter than the surface of the wall plate. After the installation of the top warehouse plate, the 10mm gap shall be marked with foaming material to ensure the sealing performance of the warehouse body.


BiuMedical refrigeration cold storageStrong compiling ability



The service life of the cold storage depends on the quality of the refrigeration equipment, but it also has a great relationship with the proper daily management and maintenance after the installation of the cold storage. Many times people often ignore the latter point. In daily life, as long as we maintain and maintain the cold storage regularly, we can greatly improve the service life of the cold storage and reduce the cost.

The cheapest.The cold storage shall be regularly overhauled and maintained,BiuPrice and installation of cold storage, so as to reduce the failure rate of the refrigeration unit and achieve good refrigeration effect.

Air conditioning monitoring pan geographic air conditioning room monitoring system consists of front-end equipment, bleach, formalin, etc. Specifically, after the fish comes out of the freezer, clean the frost layer on the evaporating pipe group and keep the storehouse temperature below 50 degrees Celsius. Then, according to the volume of 50~100 grams per cubic meter volume of the frozen storeroom, and the blower is started intermittently, so that the vinegar evaporates and flows in the storehouse, which makes the vinegar absorb a lot of fish smell.

Biu.2 - cold storage

The cold storage board uses light polyurethane as the inner material of the cold storage board. The advantage of polyurethane is that the thermal insulation performance is very good. The exterior of polyurethane cold storage board is composed of SII, PVC color steel plate and stainless steel plate. The advantage of this is to prevent the temperature transmission of cold storage board due to large internal and external temperature difference, so as to make the cold storage more energy-saving and improve the working efficiency of cold storage.

We must often use insulation board in our life. It's just the structure of the refrigerator, but the refrigerator, as a in the home,BiuCold storage installation manufacturer, still has some use environment. In the market or marine transportation,BiuInstallation of cold storage, the environment of cold storage insulation board is not so optimistic. Professional cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage quality assurance. During the preferential activities, new and old customers are welcome to consult. The environmental differences inside and outside the cold storage insulation board are very large, because a large number of items need to be insulated, so the temperature in the cold storage is strict. In such cases, the cold storage insulation board will have relevant problems Let's understand that the water vapor pressure outside the plate warehouse of the lower cold storage is higher than that inside the warehouse, and the penetration of the envelope is carried out from outside to inside all year round. R11 gas in polyurethane is replaced by air and water vapor to damp polyurethane. Over time, moisture becomes more and more serious, and even water vapor condensation occurs, resulting in low thermal conductivity and reduced thermal resistance. In order to avoid and delay polyurethane moisture and prolong the service life of the insulation layer, it is effective to seal the hot side of the insulation layer, that is to form a vapor barrier layer.