MinamirinkanInstallation price of vegetable cold storagePursue excellence

announcer:hp632HP195506591 release time:2021-12-10 16:52:55

According to the size and nature of the cold storage area and in combination with local regulations, the construction form of food cold storage warehouse is to determine the plane layout based on the site, whether it is a single-layer or double-layer warehouse, and the structure is the selection of steel structure or reinforcement solidification. Cold storage capacity, production process, refrigeration, product stacking, temperature, etc. are used to determine the size and location of the cold storage room, so that it can become a whole.

The structure of contemporary cold storage is in the development trend of prefabricated building cold storage. It is made into prefabricated components of cold storage including steam barrier and heat insulation plate to ensure on-site assembly. Its advantage is that the project construction is convenient, rapid and movable, but the project cost is relatively high.

Minamirinkan.Clean the bearing and replace the oil in the centrifugal pump, and the vibration of the shaft.

Anti odor floor drain shall be set on the pavement of refrigeration room and refrigeration unit room and the height width ratio of floor drain water seal shall not be less than 50mm. The elevator shaft, electronic pit and other places convenient for drainage shall be provided with drainage and equipment to avoid backflow of water.

.Regular oil discharge, descaling and air discharge: when there is a 0.1mm thick oil film in the evaporator coil, in order to maintain the set temperature requirements, the evaporation temperature will decrease by 5 ℃ and the power consumption will increase by more than 10; When the scale on the water pipe wall in the condenser reaches 5mm, and the power consumption will increase. When the refrigeration system is mixed with non condensable gas and its partial pressure reaches 0.196mpa the power consumption will increase by about 1

During installation, the plates shall be handled with care. Rough operation is strictly prohibited. Burrs shall be removed at the cutting opening to prevent scratching the plate surface and workers.

Large space rate of quick-frozen warehouse: for quick-frozen warehouses of the same size, reasonable design schemes store more goods than unreasonable ones. For the fixed size quick freezing warehouse, how to design it to maximize its space rate is often an important problem considered by our designers. In the design scheme of Lukang medical quick-frozen warehouse, we reasonably designed to expand the original storage capacity of 300 boxes to 400 boxes, which increases the space a lot.


MinamirinkanInstallation price of vegetable cold storagePursue excellence



During the use of cold storage, attention shall be paid to the collision and scratch of the storage body to avoid the depression and corrosion of the storage plate, which will seriously reduce the local thermal insulation performance of the storage body.

Another point is the ground maintenance measures in the wholesale of large fresh-keeping warehouses., Because the wholesale floor of large-scale prefabricated fresh-keeping warehouse is also a thermal insulation board, there will be a lot of ice on the ground in the process of use, so when cleaning these ice layers, you should pay attention not to beat them with a hammer or shovel, because it will damage the thermal insulation board on the ground. If the thermal insulation board is damaged, it will affect the thermal insulation performance of the wholesale of fresh-keeping warehouse.

2 - cold storage

Sincere service.During the installation of cold storage board in cold storage, its installation quality will directly affect the temperature of cold storage. As an important structure used in the cold storage, the cold storage board should pay attention to the details of its installation find out the problems that are easy to be ignored, and avoid the wrong installation, which will affect the use of the cold storage or the whole installation process, so as to waste resources and increase the cost.

The insulation board of the cold storage adopts polyurethane double-sided color steel plate. The main effect of this cold storage insulation board is good sealing performance, insulation effect and moisture-proof effect, so as to ensure the refrigeration effect of the cold storage. The electric cold storage door is adopted for the cold storage door, and the cold storage management personnel can timely and effectively open and close the door when entering and leaving, so as to avoid the loss of refrigeration capacity of the cold storage.

The products stored in the medical cold storage project must be managed by color code, so as to avoid the problem of purchase errors. In the process of handling, it is also necessary to strictly follow the instructions.


MinamirinkanInstallation price of vegetable cold storagePursue excellence



Whether the water pump works normally and whether the moldy switch is effective. In case of abnormality, timely handle the overhaul and maintenance of the refrigeration compressor in the cold storage: generally the refrigeration oil and drying filter shall be replaced 30 times after the operation of the cold storage equipment. Replacement after half a year. Depending on the circumstances.

demand.Connect the refrigeration system. Wires and copper pipes shall be used to connect the refrigeration unit, electric control system and other components of the cold storage. The connecting pipes shall be closely connected, and corresponding thermal insulation and protection measures shall be taken.

All lifting bolts of the cooling fan shall be fastened. Professional cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, high price, service, on-site settlement, honest management! The holes of bolts and lifting bolts shall be sealed with sealant to prevent cold bridge and air leakage.

The water tank is designed to be separated from the machine body and is double-layer. It will not drip due to condensation caused by internal and external temperature difference. It can be interlocked with the refrigeration system, that is, it will not be humidified during refrigeration to prevent serious frosting of the fan.

Minamirinkan.The combined cold storage door starts frequently or does not start for a long time, or does not stop for a long time, or stops before the storage temperature reaches.

If there is more air or refrigerant oil in the evaporator, the heat transfer effect will be reduced: once more refrigerant oil is attached to the inner surface of the evaporator heat transfer tube, the heat transfer coefficient will be reduced. Similarly, the heat exchange area of the evaporator will be reduced, the heat transfer efficiency will be significantly reduced, and the decline rate of warehouse temperature will be slowed down.

The foundation of cold storage is affected by low temperature, and the water in the soil is easy to be frozen. Due to the volume of frozen soil, the ground will be broken and the whole building structure will be deformed. If the damage is serious, in addition to the thermal insulation layer, the floor of low-temperature cold storage must be treated under the thermal insulation layer to prevent soil freezing. The bottom plate of the cold storage shall stack a large number of goods and pass through various loading, unloading and transportation machinery and equipment. Therefore, the structure of the cold storage plate shall be firm and have large bearing capacity. In low temperature environment, especially in the process of periodic freezing and thawing cycle, building structures are vulnerable to. Therefore, the structure of each part of the cold storage and the building materials of the cold storage should have sufficient frost resistance.