GuihuVegetable cold storageGuarantee of processing and production

announcer:hp632HP195506591 release time:2022-02-26 15:32:26

However, long-term continuous operation will inevitably lead to equipment aging, so reasonable maintenance is particularly important.

The polyurethane insulation board used in the construction of cold storage shall be integral and continuous, and there shall be no joint in the middle. The junction of polyurethane insulation board top plate and ground shall be made into fillet arc for transition, which can well meet the health needs.

Guihu.Transportation: before the installation of the fresh-keeping storehouse, handle it with care, and lay an anti scratch layer on each layer of the warehouse board and the ground joint.

Families will also be equipped with some simple refrigeration devices. For refrigeration devices such as cold storage, it is very important to select materials with good thermal insulation. Cold storage is a better material selection, and in the production process of cold storage, there will be no condensation in the cold storage of the plant. Condensation inside the cold storage or inside the insulation layer is harmful. Irreversible damage or deformation occurs in the new external insulation, and the external surface temperature of the external wall changes sharply. For example, the insulation and sound insulation effects of polyurethane insulation board are relatively good, which can be used in many industries. As we all know, the cold storage has great requirements for the thermal insulation effect of building materials. If the thermal insulation effect of building materials is not good, the cold storage will consume more energy during operation, and can not guarantee a good refrigeration effect. The performance of polyurethane insulation board meets the construction requirements of cold storage, so a large number of polyurethane insulation boards need to be used in the construction of general cold storage. Next, let's understand the physical properties of polyurethane insulation board.

.Disadvantages of multi-layer cold storage: the vertical transportation volume of the warehouse is large and the goods in and out and operation management are not as convenient as single-layer cold storage; With the development of the floor load capacity, the floor area ratio of each cold room is low; When the multi-storey cold storage is built on the foundation with poor ground resistance, the foundation construction is complex. High cost; When prefabricated components are used, large construction equipment is required and the construction period is long.

Generally speaking, the construction of cold storage is to ensure the quality of buildings with its strict heat insulation, sealing, firmness and frost resistance.

Disadvantages of multi-layer cold storage: the vertical transportation volume of the warehouse is large, and the goods in and out and operation management are not as convenient as single-layer cold storage; With the development of the floor load capacity, the floor area ratio of each cold room is low; When the multi-storey cold storage is built on the foundation with poor ground resistance, the foundation construction is complex. High cost; When prefabricated components are used, large construction equipment is required and the construction period is long.


GuihuVegetable cold storageGuarantee of processing and production



The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration it shall be able to ensure the reliable power supply of the exhaust fan. The overload protection of the exhaust fan should be applied to the signal alarm system without directly stopping the exhaust fan. The button box of the exhaust fan shall be concealed in the wall outside the ammonia compressor room.

The gap between the cooling fan and the storage plate shall be greater than the thickness of the cooling fan.

It is built in the room. There shall be excellent drainage pipe standards around the cold storage, the soil temperature shall be low, there shall be interlayer under the cold storage, before the construction of the cold storage, the phase electricity of the relative volume shall be built according to the output power of the refrigeration unit. If the cold storage is water-cooled and radiating, the tap water pipeline shall be paved and the FRP cooling tower shall be built.

Statistics.Some cold bridge prevention measures shall be taken at the joints between polyurethane insulation boards.

With the increasing use of cold storage, cold storage board, as an important structure of cold storage, is also increasing. Because cold storage is different from other ordinary cold storage, it is important to the installation environment and temperature. Therefore, some small problems may be ignored during installation. According to the following understanding.

Drainage measures shall be provided for the villa room and overhead layer of the road surface of the cold storage engineering building.


GuihuVegetable cold storageGuarantee of processing and production



Technical assurance measures for the installation of cold storage: during production in the production workshop, the production shall be carried out in strict accordance with the operation rules specified in ISO9002 quality operation, self inspection and inspection application shall be carried out to ensure that the factory pass rate is, and unqualified products are not allowed to leave the factory.

Total quality management.The overall construction achievements of the cold storage project have been put into use, and the service life can reach 10 years.

If the controlled atmosphere storage works continuously for more than 2000h, medium maintenance shall be carried out. The condenser, evaporator and cooling exhaust pipe shall be overhauled once a month. The maintenance contents are as follows: the condenser evaporator and cooling drain pipe are cleaned and adjusted, the cooling water distribution device is cleaned and adjusted, the brine distribution device is cleaned and adjusted, the cooling drain pipe is repaired and the pipe leakage fault is eliminated.

For the flushing (thawing) drainage pipe in the cold room with different temperature, an exhaust valve equipment shall be set before connecting the flushing (thawing) drainage pipe.

Guihu.The two sets of connectors between the cold storage shall be wedged tightly, and the two sets of connectors shall be fixed at the upper, outer and lower sides of the cracks in the cold storage respectively. The lower connector shall be as close as possible, so as to facilitate the use of concrete to cover the connector in the future.

Strong deformation resistance, not easy to crack, smooth, stable and safe. Polyurethane material has stable porosity structure and basically closed pore structure. It not only has excellent thermal insulation performance, but also has good freeze-thaw resistance and sound absorption performance. Under normal service and maintenance conditions, it can reach the unit price of dry, wet or electric corrosion under normal service conditions, while the unit price of insect, fungus or algae foam material is higher than other traditional insulation materials, but heating will increase the cost and the cooling cost will be greatly reduced.

Installation of box and operating device: the design of box shall be reasonable, etc. shall be reliable, safe, long-term cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage, 20-year-old brand, price advantage and quality guarantee! Easy to identify and operate. The indicator light shall be simple and clear. The device and each switch shall be installed on the upper side outside the warehouse door, which is easy to operate, read data and not easy to be damaged, and shall be reliably fixed. The device box is installed on the door frame plate on the door opening side. The center line of the box overlaps the center line of the door frame plate. The bottom of the box is 1800mm above the ground and is reliably fixed. The lighting lamp and door frame wire switch in the warehouse are installed directly below the device, and the height of the bottom edge of the switch box is about 1400mm.