MontrealInstallation of large cold storageExcellent quality

announcer:hp632HP195506591 release time:2022-02-17 10:29:03

Relative humidity maintenance of quick-frozen warehouse: humidification of quick-frozen warehouse is very important, from centrifugal humidification to high-pressure micro fog humidification, to the current ultrasonic humidifier. The utility model has the advantages of small particles, uniform humidification, no freezing and blocking, which is essentially different from other humidifiers in the market: fully closed circulation that is, take the gas in the warehouse, return to the warehouse through the humidifier and isolate it from the outside air.

When outdoor air enters the cold storage body, but also bring water into the warehouse. The condensation of water will lead to the building structure, especially the heat insulation structure, being damaged by moisture and freezing. Therefore, a moisture-proof and heat insulation layer should be set to keep the cold storage board building moisture-proof and air-proof performance and good sealing.

Montreal.After the refrigeration system is installed it shall be beautiful and color. There shall be no cross height inequality of pipelines.

Wall and floor fixtures shall start at corners. According to the plate layout drawing, transport the two plates at the corner of the required device to the device location. According to the plate beam height and the model of the angle iron for fixing the mushroom head nylon bolt, drill a hole at the corresponding elevation in the middle of the plate width. When drilling,MontrealInstallation of large cold storage, the electric drill should be perpendicular to the plate surface. Put the mushroom head nylon bolt in the hole, tighten the angle iron, and tighten it horizontally, so as to make the nylon bolt on the surface of the warehouse plate slightly concave. When setting up the wall panels, foam data and other soft data should be laid on the floor slots along with the floor of the storehouse, so as to avoid damaging the storehouse. After the two corner panels are neutrally removed from the floor, the plane position of the wallboard and the verticality of the storehouse should be adjusted in time according to the location of the laying line, and check whether the top elevation of the wallboard can be correct. After the position of the wallboard is correct, weld the angle iron on the plate beam and fix the inner and outer corners. When welding the angle iron parts, the angle iron parts of the warehouse plate shall be covered with a shield to avoid the high temperature of the welding ground baking the warehouse plate and welding slag on the warehouse plate during electric arc welding.

.The equipment that needs to be installed in the warehouse and put into the warehouse shall be installed in place or placed in an appropriate position in the warehouse; The wall warehouse board shall be installed from the corner of the warehouse body, and the professional cold warehouse shall be installed. The cold warehouse shall be installed. The cold warehouse shall be constructed. The fruit fresh-keeping cold warehouse and medical cold warehouse shall have high pressure rating, good waterproof performance, fire and high temperature resistance, strong overload capacity, corrosion resistance, radiation protection and long service life. The corner shall be temporarily fixed with 0.5 color plate angle steel; When installing each wall panel, evenly apply two layers of foaming material on the joint surface of male and female groove, and apply one layer of foaming material when installing polystyrene wall panel. The blanking shall be uniform and continuous; After the wallboard is installed in place, pull rivets at the lap joint of the internal and external steel plates of the two wallboards for connection and fixation, and the rivet spacing in the warehouse should be 300mm; When connecting the library plate in the form of eccentric hook connection, the eccentric hook shall be loosened once before installation to ensure reliable locking during installation.

The installation of top warehouse plate should be carried out alternately with the installation of wall plate, and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, the end steel sheet at the overlap with the wall plate shall be disconnected for 50mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, and the rivet spacing shall be 300mm; According to the design drawings, if there are supporting beams, columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam,MontrealWhich one do you want for cold storage installation, column, support steel frame, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.

Polyurethane foam: This is also a very common cold storage material. It has strong thermal insulation effect and strong mechanical strength. Now it is widely used and has a good application prospect.


MontrealInstallation of large cold storageExcellent quality



These measures have achieved quite good results. Compared with several cold storages at a customer in Jining,MontrealInstallation and construction of cold storage, the cold storages using their white materials have significantly lower power consumption than those using other white materials.

If the warehouse is relatively small and you want to transform a miniature fruit fresh-keeping warehouse, you should ensure that the height in the warehouse is at least 8 meters, because the top of the cold storage and the top of the warehouse should reserve a height of at least 30 cm.

When the cold storage is used for the first time or shut down for a long time, it is strictly prohibited to stack goods in the warehouse. The warehouse must be slowly reduced to the required temperature. For the low-temperature warehouse, it needs to be cooled in stages to avoid sudden changes in the temperature difference inside and outside the warehouse, resulting in the warehouse body.

supply.Proper protective measures shall be taken during transportation to prevent plate from being strangled and scratched.

Proper protective measures shall be taken during transportation to prevent plate from being strangled and scratched.

Disadvantages of single-layer cold storage: large; The surface area of the external enclosure structure of the cold storage is large, so the amount of thermal insulation materials is large, and the dry consumption of cold food is also large; For the low-temperature warehouse, the floor anti freezing treatment requires a large amount of work. When the cold storage is built at the water level, it is impossible to deal with it, which is easy to cause horizontal freezing and swelling.


MontrealInstallation of large cold storageExcellent quality



The combined cold storage door starts frequently or does not start for a long time, or does not stop for a long time, or stops before the storage temperature reaches.

Quality risk.The closed cell structure and surface material of polyurethane rigid foam with good moisture-proof, waterproof and corrosion resistance make it have better air resistance and water vapor resistance, and it can be made into inlaid connection structure during forming, which is easy to assemble. It does not need additional insulating layer to prevent moisture and saves a lot of trouble in laying insulating layer.

The overall layout of the unit is reasonable and the color is. The installation structure of each type of unit shall be consistent.

Simple refrigeration is based on the volatilization of refrigerant in the condenser of the cold storage, so as to cool the refrigerant, and then input the refrigerant into the box or building of the refrigeration equipment to cool the air according to the heat exchanger. This kind of refrigeration has slow cooling speed, large total heat conduction temperature difference and complex system software so it can only be used in less places, such as brine ice making and cold storage with constant temperature requirements.

Montreal.We must often use insulation board in our life. It's just the structure of the refrigerator, but the refrigerator, as a in the home, still has some use environment. In the market or marine transportation, cold storage installation, cold storage construction, fruit preservation cold storage medical cold storage quality assurance. During the preferential activities, new and old customers are welcome to consult. The environmental differences inside and outside the cold storage insulation board are very large, because a large number of items need to be insulated, so the temperature in the cold storage is strict. In such cases, the cold storage insulation board will have relevant problems, Let's understand that the water vapor pressure outside the plate warehouse of the lower cold storage is higher than that inside the warehouse, and the penetration of the envelope is carried out from outside to inside all year round. R11 gas in polyurethane is replaced by air and water vapor to damp polyurethane. Over time moisture becomes more and more serious, resulting in low thermal conductivity and reduced thermal resistance. In order to avoid and delay polyurethane moisture and prolong the service life of the insulation layer, it is effective to seal the hot side of the insulation layer, that is, to form a vapor barrier layer.

1 - precautions for floor installation of cold storage: the floor shall be installed flat, the uneven part shall be leveled with materials, and the locking hook between the plates shall be locked to ensure that the warehouse surface is flat without hollow feeling. (note that if this drainage system is installed outdoors in the north, the drainage pipe shall be insulated).

Clean and professional cold storage installation, cold storage installation, cold storage construction, fruit fresh-keeping cold storage, medical cold storage have stable performance, safety, reliability and maintenance free. The technical level has reached the domestic level and the advanced level of similar international products. If there is a large amount of ice and water, it must be cleaned in time, and it must not be knocked during cleaning