Virginia-BeachRefrigerator manufacturerHow to compensate for the modification

announcer:hp632HP195506591 release time:2022-01-10 16:17:50

Requirements for the cold storage time of the device: the cold storage of the refrigeration system using ammonia as refrigerant shall be supported in the place with low population density around.

The bubble density is 38 kg to 40 kg / m3 per cubic meter, and the steel plate thickness generally needs to be more than 0.4 mm to meet the standard. On the market, the main raw materials of special cold storage board for cold storage project are polyphenylene, polyethylene and polyphenylene grease. The density of thermal insulation material foamed by polyphenylene is thin, and the thermal insulation coefficient is not very high; After a certain ratio of polyethylene, it can foam cold storage insulation materials with appropriate density and good thermal insulation effect, and has high load-bearing capacity; Polyphenylene resin has strong water absorption, but poor heat insulation. Therefore, the polyurethane sandwich board with very good performance belongs to the polyurethane sandwich board. Although it is slightly higher, the polyurethane board has very good thermal insulation performance and does not absorb moisture.

Virginia-Beach.After the welding of the whole system, the air tightness test shall be carried out, and the high-pressure end shall be filled with 8mp nitrogen. Nitrogen charging 2MP at low pressure end. During pressurization conduct leak detection with soapy water, and carefully inspect all welded junctions, flanges and valves, so as to keep the pressure from falling off after the completion of simplicity.

The installation of top warehouse plate should be carried out alternately with the installation of wall plate, and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, the end steel sheet at the overlap with the wall plate shall be disconnected for 50mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, and the rivet spacing shall be 300mm; According to the design drawings, if there are supporting beams, columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, column, support steel frame, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.

.The service life of polyurethane cold storage insulation material foam is: besides the basic performance of the initial stage of polyurethane foam, the deterioration of foam performance is also a very important index. When the white material is prepared, the surface of some polyester materials can make the foam have better toughness and impact resistance, but it will become brittle after use for a long time in the cold storage, and will no longer resist impact and collision. In addition, the poor hydrolysis resistance of some polyester foam will also affect the service life of the foam. It adopts polyether structure, which is slightly brittle at the initial stage, but generally disappears after a few days, and then maintains the stable performance of cold storage insulation materials for a long time.

How to maintain the refrigeration compressor in the cold storage in order to prolong its service life and reduce the occurrence of faults in the use process. The refrigeration compressor in the cold storage needs regular maintenance. Here we introduce the maintenance of the compressor in the cold storage.

Goods in and out frequently, throughput


Virginia-BeachRefrigerator manufacturerHow to compensate for the modification



The use of large-scale cold storage is naturally very strict in installation and material selection. Therefore, in the face of the above possible situations, we can strictly screen the insulation board materials of cold storage, which can effectively alleviate or solve the above problems. However at present, there are many fields using cold storage insulation board, so the details of the use environment should be considered for the wood making of many such products in the market.

Does the cable wire meet the parameters? In general, the cold storage needs to use phase electricity.

Installation of box and operating device: the design of box shall be reasonable, and the appearance quality shall meet the requirements of beauty and practicality. All buttons, electrical switches, etc. shall be reliable, safe, long-term cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage, 20-year-old brand, which is easy to operate, read data and not easy to be damaged, and shall be reliably fixed. The device box is installed on the door frame plate on the door opening side. The center line of the box overlaps the center line of the door frame plate. The bottom of the box is 1800mm above the ground and is reliably fixed. The lighting lamp and door frame wire switch in the warehouse are installed directly below the device, and the height of the bottom edge of the switch box is about 1400mm.

Where is it.Disadvantages of single-layer cold storage: large; The surface area of the external enclosure structure of the cold storage is large, so the amount of thermal insulation materials is large, and the dry consumption of cold food is also large; For the low-temperature warehouse, the floor anti freezing treatment requires a large amount of work. When the cold storage is built at the water level, it is impossible to deal with it, which is easy to cause horizontal freezing and swelling.

These measures have achieved quite good results. Compared with several cold storages at a customer in Jining the cold storages using their white materials have significantly lower power consumption than those using other white materials.

The refrigeration equipment in the fresh-keeping environment of the quick-frozen warehouse mostly adopts the single-stage compression refrigeration system, with freon as the refrigerant. The evaporation mode in the warehouse is the cooling fan, which can be ceiling type. If the number of warehouses is small and the volume does not exceed 500 cubic meters the refrigeration mode of the warehouse machine can be considered. If there are a large number of warehouses, the mode of multiple heads in parallel can be considered.


Virginia-BeachRefrigerator manufacturerHow to compensate for the modification



1 - precautions for floor installation of cold storage: the floor shall be installed flat, the uneven part shall be leveled with materials, and the locking hook between the plates shall be locked to ensure that the warehouse surface is flat without hollow feeling. (note that if this drainage system is installed outdoors in the north, the drainage pipe shall be insulated).

Installation conditions.Installation of box and operating device: the design of box shall be reasonable, and the appearance quality shall meet the requirements of beauty and practicality. All buttons, electrical switches, safe long-term cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage, 20-year-old brand, price advantage and quality guarantee! Easy to identify and operate. The indicator light shall be simple and clear. The device and each switch shall be installed on the upper side outside the warehouse door, which is easy to operate, read data and not easy to be damaged, and shall be reliably fixed. The device box is installed on the door frame plate on the door opening side. The center line of the box overlaps the center line of the door frame plate. The bottom of the box is 1800mm above the ground and is reliably fixed. The lighting lamp and door frame wire switch in the warehouse are installed directly below the device, it is also important to pay special attention to the maintenance of fresh-keeping storehouse equipment in the whole process of application. Here are some key maintenance matters.

In order to ensure the safety of construction and cold storage operation, the span between the top storage plate supports (lifting points) shall comply with the following provisions: the polystyrene top storage plate (100mm thick) has a very large span of 3M, and the polyurethane top storage plate (100mm thick) has a span of 5m.

Virginia-Beach.The quick-frozen warehouse is easy to load and unload. All the plates and walls of the quick-frozen warehouse are produced by molds. You can choose tens of millions of products. Professional cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage and transaction safety are guaranteed. Through internal concave convex groove connection, loading, unloading and handling are convenient. The installation period is short. Small and medium-sized cold storage can be delivered in 2-5 days, The library body can be combined, separated or increased or decreased according to the needs of users.

Cold storage is fireproof, flame retardant and high resistance. Professional cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage and other special products, 20-year-old brand, price advantage and guaranteed quality. Polyurethane is a flame retardant self extinguishing material after adding flame retardant. Its softening point can be above 250 degrees Celsius and will only be decomposed at higher temperatures. In addition, the ash formed on the surface of polyurethane will be in its foam, polyurethane will not produce harmful gas at high temperature.

Some cold bridge prevention measures shall be taken at the joints between polyurethane insulation boards.