CiputatWhere is a large cold storageWhy does the air volume become smaller after using it for a long time

announcer:hp632HP195506591 release time:2021-12-09 09:22:54

The refrigerator compressor unit generally adopts high-end units with guaranteed quality and strong operation stability. The evaporator adopts the imported joint venture refrigeration air-cooled evaporator, which can effectively meet the refrigeration capacity of the refrigerator and ensure the refrigeration effect of the refrigerator. The refrigerator lamp adopts the special LED energy-saving lamp for the refrigerator, which has the advantages of low temperature resistance, low energy consumption and long service time, It can effectively save the operation cost of cold storage.

At ordinary times, users should check the sealing degree of the gap of the cold storage, and notify the cold storage for maintenance in time if damaged parts are found.

Ciputat.Disadvantages: high precision requirements, shape and position tolerances are in micron level; No exhaust valve, poor off design performance; The working chamber is not easy to implement external cooling, and the heat in the compression process is difficult, so it can only compress the gas with small adiabatic index or internal cooling; Large displacement scroll refrigeration unit is difficult to realize. The receiving teeth are high, the displacement is large, the diameter is large, the butt joint shall be filled with foaming material, and the 80mm wide color steel plate shall be sealed at the butt joint with pull riveting.

.The cold storage board uses light polyurethane as the inner material of the cold storage board. The advantage of polyurethane is that the thermal insulation performance is very good. The exterior of polyurethane cold storage board is composed of SII, PVC color steel plate and stainless steel plate. The advantage of this is to prevent the temperature transmission of cold storage board due to large internal and external temperature difference, so as to make the cold storage more energy-saving and improve the working efficiency of cold storage.

During operation, the water temperature will still drop and the humidification amount will be reduced by 70% at 5 ℃.

1 - floor installation of cold storage: first level the floor, then install the floor, select a beautiful floor and put it in a conspicuous place, and do a good job in the floor and evaporator drainage system.


CiputatWhere is a large cold storageWhy does the air volume become smaller after using it for a long time



Where do you need to build the refrigerator, the size of the refrigerator or the storage capacity (size storage capacity, ton, cubic meter, frame, box); What products are stored in the built cold storage? The actual storage temperature, storage time and setting temperature can be indicated by specific regulations; If your cold storage becomes larger, you need to master your individual storage volume, the temperature of goods in and out of the warehouse, the frequency of opening and closing the door, etc. If this is clear, it is the selection of raw materials, such as refrigeration compressors, refrigeration units, industrial cooling fans / pipe slots, thermal insulation materials, coolers, doors, temperatures and other refrigeration equipment.

Compared with the logistics engineering design of ordinary commodities, the logistics refrigeration engineering commonly used in the circulation of fresh food should follow more stringent design specifications and use requirements, so as to maintain the freshness of circulation and prolong the freshness period of fresh food. In recent years, with the frequent cross regional trade, KFC refrigeration has received more and more demand in the design and construction of logistics refrigeration engineering. What are the basic functions of logistics refrigeration engineering in design?

The common phenomenon of quick freezing storehouse is that the temperature of quick freezing storehouse can't drop down or drops slowly. Now, a simple analysis is made on the reasons for the slow drop of temperature: the cold capacity loss of quick freezing storehouse is large due to poor thermal insulation or sealing performance; the poor thermal insulation performance is due to insufficient thickness of thermal insulation layer of pipeline and warehouse thermal insulation wall, resulting in poor thermal insulation and thermal insulation effect, It is mainly caused by improper selection of insulation layer thickness in design or poor quality of insulation materials in construction.

Quality risk.There are many kinds of cold storage. According to the material, it can be divided into color steel plate, stainless steel plate and salted steel. Among them, color steel plate has strong anti rust ability, while salted steel has both beautiful appearance and anti rust ability. According to the layout, it is divided into flat plate and wave plate. The former is flat after the surface material is formed, and the latter is rugged after the surface material is formed. According to the thickness and color of surface materials the thickness of stainless steel is 0.5mm and 0mm, without color requirements; The thickness of salted steel plate is 0.5mm without color requirements; The thickness of PE paint baking board is 0.5mm, 0.8mm ivory white, titanium white and white gray. The most important thing for the cold storage is the applicable temperature of the cold storage. It is divided according to the insulation thickness of the storage plate. The thickness of the sky floor of the 150 mm storage plate is 150 mm, and the thickness of the vertical plate is 160 mm and 100 mm, which is suitable for the insulation conditions of - 25 ℃ ~ - 45 ℃; 100mm storage plate: the thickness of the ceiling plate is 100mm and the thickness of the vertical plate is 110mm, which is suitable for the thermal insulation conditions of 0 ℃ ~ - 25 ℃. The thickness of the ceiling plate and the vertical plate of 60mm storage plate is 60mm, which is suitable for the thermal insulation conditions above 0 ℃. In fact, there are many other classification methods of cold storage. Determined by the current processing technology, it can be divided into standard plate and non-standard plate according to the width and size range of warehouse plate, including standard plate vertical plate width wa = 900mm, heaven and earth plate width WB = 980mm, vertical angle plate W1 = 790mm, W2 = 840mm, W3 = 740mm and W4 = 880. The dimensions of non-standard plates are different from those of Wa, WB and W4.

Cold storage has good fire and flame resistance. After adding flame retardant, unlike flow burning and flashover like extruded board it can be carbonized, which can effectively prevent fire spread. In particular, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage. Waste merchants, industry, enterprises and power departments are welcome to visit and negotiate! The cold storage body and storage plate include: floor, vertical plate and ceiling plate. The installation of storage plates in different directions and precautions are as follows: enter the construction site, verify the construction situation according to the construction drawings, determine the equipment installation position, and then refer to the following specifications.


CiputatWhere is a large cold storageWhy does the air volume become smaller after using it for a long time



With the development of the times, refrigeration devices are becoming more and more common. All aspects of life are inseparable from its use. Families will also be equipped with some simple refrigeration devices. For refrigeration devices such as cold storage, it is very important to select materials with good thermal insulation. Cold storage is a better material selection, and manufacturers need it in the production process of cold storage

Inspection basis.The drainage at the outlet of the cooling fan, but indirect drainage shall be adopted. For the flushing (thawing) water drainage of each layer in the double-layer cold storage, an exhaust valve equipment shall be set in front of the main riser for flushing (thawing) water drainage.

Evaporation temperature the sweating temperature of the refrigeration in the wafer machine needs to be lower than the air temperature in order to transfer heat from the engine room to the refrigerant. Usually, the temperature difference of room air conditioner is between 12C and 14C. If the temperature difference cannot be maintained due to adverse factors, the operation energy consumption will increase.

Establish a perfect computer network, make the distribution of refrigeration supply chain scientific, and achieve the traceability of food safety. In the European Union, the United States and Japan, all members of the food supply chain have the legal responsibility to implement traceability.

Ciputat.After the cold storage at the corner is installed, the next cold storage can be installed along the direction of the corner. Adopt the similar installation of Zhang cold storage to install the thermal insulation board of the storage. Professional cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage, advanced technology, strict testing, more affordable price and more preferential. Welcome to consult. Pay attention to its compactness and continuous uniformity.

The bacterial action of acid disinfectants is mainly to coagulate the protein in the bacteria. Common disinfectants include lactic acid, formalin, etc. Specifically, after the fish comes out of the freezer, clean the frost layer on the evaporating pipe group and keep the storehouse temperature below 50 degrees Celsius. Then, according to the volume of 50~100 grams per cubic meter volume of the frozen storeroom, the storeroom door is closed tightly with the sprayer, and the blower is started intermittently, so that the vinegar evaporates and flows in the storehouse, which makes the vinegar absorb a lot of fish smell.

The spacing of pull rivets at inner and outer corners is 300mm and 200mm respectively; After the polystyrene library is installed the wall panel joints shall be evenly sealed and decorated with silicone sealant.