AmagasakiDesign and installation of medical cold storageSpeed ​​up the progress of construction

announcer:hp632HP195506591 release time:2021-12-09 19:52:55

When opening and drilling is required for the top warehouse plate or wall plate, the internal and external setting out and positioning shall be carried out according to the drawing design requirements, liquid inlet hole return hole, water supply hole and drainage hole shall be opened with a hole opener. Construction treatment shall be carried out in time after opening and drilling, and the orifice shall be closed with foaming material or sealant to prevent air leakage and cold running; The door, vent and delivery port shall be decorated with wrapped edges and fixed with pull rivets, with a spacing of 300mm and 150mm outside.

The equipment configuration is reasonable and the service life of the quick freezing warehouse is long. The reasonable equipment configuration of the quick freezing warehouse can greatly prolong the service time of the quick freezing warehouse. Some compressors are easy to be damaged when they work at full load for a long time, so we try to use screw parallel units. The great advantage of this unit is that it can turn on all equipment, just like the shift at work, so that the compressor can work and rest in turn.

Amagasaki.The machine room shall be kept clean and well ventilated, and the condenser shall be cleaned and masonry removed regularly to ensure the normal and stable operation of the unit.

Frequently observe the operation state of the heart compressor of the cold storage equipment and its exhaust temperature. During the season change operation, the deterioration of foam performance is also a very important index. When the white material is prepared the surface of some polyester materials can make the foam have better toughness and impact resistance, but it will become brittle after use for a long time in the cold storage, and will no longer resist impact and collision. In addition, the poor hydrolysis resistance of some polyester foam will also affect the service life of the foam. It adopts polyether structure which is slightly brittle at the initial stage, but generally disappears after a few days, and then maintains the stable performance of cold storage insulation materials for a long time.

Install the temporary lighting facilities in the warehouse, install and arrange the construction electrical equipment, and do a good job in rain proof, moisture-proof, anti-collision anti binding and other safety protection.

The quantity is large, and a special tally room (area) is set according to the needs of production and operation. The temperature of the tally area is usually controlled at 0 ~ + 7 ℃.


AmagasakiDesign and installation of medical cold storageSpeed ​​up the progress of construction



Reasonable space: the power consumption of the cold storage is calculated according to the cold consumption of the cold storage, which usually includes two parts: the cold consumption during cargo cooling and refrigeration; It is the cooling consumption of the refrigeration room itself and operation management.

Therefore, the cold storage also needs regular maintenance every year, so as to ensure its stable operation.

How to maintain the refrigeration compressor in the cold storage in order to prolong its service life and reduce the occurrence of faults in the use process. The refrigeration compressor in the cold storage needs regular maintenance. Here we introduce the maintenance of the compressor in the cold storage.

technological innovation.For the flushing (thawing) drainage pipe in the cold room with different temperature, an exhaust valve equipment shall be set before connecting the flushing (thawing) drainage pipe.

During operation, the water temperature will still drop, and the humidification amount will be reduced by 70% at 5 ℃.

Compression refrigerator is commonly used. It is mainly composed of compressor, condenser, throttle valve and evaporation pipe. The evaporation pipe is installed in the refrigeration warehouse. When the liquid coolant passes through the evaporation pipe, it directly absorbs the heat in the warehouse and cools down.


AmagasakiDesign and installation of medical cold storageSpeed ​​up the progress of construction



Precautions for purchase and shipment when using the medical cold storage project, the speed must be strictly guaranteed during the purchase and shipment of products. If the temperature of the medical cold storage is about degrees, the opening time must be strictly within 25 minutes. If the temperature of the medical cold storage is left and right degrees, the opening time can not be too high, strictly within minutes.

recommend.The construction of cold storage in site selection bears the circulation of low-temperature goods. Therefore, the transportation convenience of cold storage construction site should be given priority in site selection, such as proximity to roads, railways, etc. At the same time, the location of the cold storage should avoid large pollution sources and direct sunlight, and the construction of the cold storage should have good drainage and ventilation conditions.

During the welding of refrigeration pipeline, a blowdown outlet shall be reserved to blow the sewage from high and low pressure with nitrogen in sections. After the sectional blowing is completed, the whole system shall be blown until no dirt is found. The blowdown pressure is 0.8MPa.

The selection of equipment for the construction of equipment cold storage is closely related to the size, type and budget of the cold storage.

Amagasaki.The butt joint between the top warehouse plate and the end of the top warehouse plate shall be treated to prevent air leakage and cold running. After all the top warehouse plates are installed, the butt joint shall be filled with foaming material, and the 80mm wide color steel plate shall be sealed at the butt joint with pull riveting.

Cold storage is fireproof, flame retardant and high resistance. Professional cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage and other special products, 20-year-old brand, and this ash will help isolate the foam below. It can effectively prevent the spread of fire. Moreover, polyurethane will not produce harmful gas at high temperature.

With the increasing use of cold storage, cold storage board, as an important structure of cold storage, is also increasing. Because cold storage is different from other ordinary cold storage, it is important to the installation environment and temperature. Therefore, some small problems may be ignored during installation. According to the following understanding.