PaeaFresh storage cold storageHigh temperature treatment measures

announcer:hp632HP195506591 release time:2021-12-17 13:17:02

The quick freezing storehouse of vegetables and fruits is not suitable to use exhaust cooling, but use fan to supply air for refrigeration, because the gas in the quick freezing storehouse needs to be circulated and dispersed regularly to avoid carbon oxide poisoning caused by high concentration of carbon oxide in local areas. Therefore, in the quick freezing warehouse, the refrigeration equipment needs to be used together with the air conditioning equipment. The selection of refrigeration equipment is different from that of low-temperature freezer and ordinary quick freezing warehouse.

Indirect cooling is that the air in the warehouse is pumped into the air cooling device by the blower. The air is absorbed by the evaporation pipe circling in the cooling device, and then sent to the warehouse for cooling. The advantages of air cooling are rapid cooling, uniform temperature in the warehouse, and can bring harmful gases such as carbon oxide out of the warehouse during storage.

Paea.Frosting of evaporator will increase thermal resistance and decrease heat transfer coefficient. For the cooling fan, the air circulation cross-sectional area is reduced, the circulation resistance is increased, and the power consumption is increased. Therefore, defrost in time. Pay attention to the maintenance of the evaporator of the controlled atmosphere storage system. If the evaporator frosts, it will affect the normal use of the controlled atmosphere storage. How to defrost in time? The current scheme of the controlled atmosphere storage includes: manual defrosting, which is simple and easy

With the increasing use of cold storage, cold storage board, as an important structure of cold storage, it is important to the installation environment and temperature. Therefore, some small problems may be ignored during installation. According to the following understanding.

.Polyurethane refrigeration board uses light polyurethane as the internal material of refrigeration board. The advantage of polyurethane is very good heat insulation. The exterior of the cold storage is composed of SII, PVC color steel plate and stainless steel plate. The advantage of this is that it can prevent refrigeration, because the temperature difference inside and outside the board is large, and the temperature will disperse, which makes refrigeration more energy-saving and improves the working efficiency of refrigeration.

According to the size and nature of the cold storage area and in combination with local regulations, the construction form of food cold storage warehouse is to determine the plane layout based on the site, whether it is a single-layer or double-layer warehouse,PaeaWhere is the cold storage installed, and the structure is the selection of steel structure or reinforcement solidification. Cold storage capacity, production process, refrigeration, product stacking, temperature, etc. are used to determine the size and location of the cold storage room, so that it can become a whole.

In fact there are some unique installation skills when installing the cold storage? The cold storage installed according to these skills is often short in both effect and quality, and the specific installation skills of the cold storage will also make some relatively detailed introduction for you in the following article. When installing the cold storage you should install it from the corner first. Later, according to the height of the cold storage, make a hole in the middle of the insulation board behind the angle iron parts


PaeaFresh storage cold storageHigh temperature treatment measures



Cold storage is fireproof, flame retardant and high resistance. Professional cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage and other special products, 20-year-old brand, price advantage and guaranteed quality. Polyurethane is a flame retardant self extinguishing material after adding flame retardant. Its softening point can be above 250 degrees Celsius and will only be decomposed at higher temperatures. In addition, the ash formed on the surface of polyurethane will be in its foam, and this ash will help isolate the foam below. It can effectively prevent the spread of fire. Moreover, polyurethane will not produce harmful gas at high temperature.

According to the needs and uses of different engineering scenarios, the design and construction of cold storage are different. When designing cold storage according to actual needs nine aspects generally need to be considered.

When opening and drilling is required for the top warehouse plate or wall plate, the internal and external setting out and positioning shall be carried out according to the drawing design requirements, and the opening and drilling shall be carried out after review; The inlet hole, liquid inlet hole, return hole, water supply hole and drainage hole shall be opened with a hole opener. Construction treatment shall be carried out in time after opening and drilling, and the orifice shall be closed with foaming material or sealant to prevent air leakage and cold running; The door,PaeaInstallation cost of fresh-keeping cold storage, vent and delivery port shall be decorated with wrapped edges and fixed with pull rivets,PaeaTemperature monitoring of medical cold storage, with a spacing of 300mm and 150mm outside.

index.Cold storage construction: which one is suitable for you? Which one is suitable for you?

Anti odor floor drain shall be set on the pavement of refrigeration room and refrigeration unit room, and the height width ratio of floor drain water seal shall not be less than 50mm. The elevator shaft, electronic pit and other places convenient for drainage shall be provided with drainage and equipment to avoid backflow of water.

The installation of top warehouse plate should be carried out alternately with the installation of wall plate, the end steel sheet at the overlap with the wall plate shall be disconnected for 50mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, and the rivet spacing shall be 300mm; According to the design drawings, columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, column, support steel frame, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.


PaeaFresh storage cold storageHigh temperature treatment measures



The ultrasonic town is a patented technology with a shaped energy cover, which increases the effective humidification amount by 50-70% per hour. What are the reasonable aspects of the design of the quick freezing warehouse?

system.Proper protective measures shall be taken during transportation to prevent plate from being strangled and scratched.

Wires should not be in the open air to avoid long-term sun exposure and wind blowing, wire skin aging, long-term cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage without turnover, so as to avoid price difference, and the price is 20% higher than the market price! The price of more than one ton is higher! Short circuit leakage, etc.

The combined cold storage door starts frequently or does not start for a long time or does not stop for a long time, or stops before the storage temperature reaches.

Paea.The construction of cold storage in site selection bears the circulation of low-temperature goods. Therefore, such as proximity to roads, railways, etc. At the same time, the location of the cold storage should avoid large pollution sources and direct sunlight, and the construction of the cold storage should have good drainage and ventilation conditions.

However, long-term continuous operation will inevitably lead to equipment aging, pay attention to whether the air curtain is opened or the door curtain is placed properly. Turn off the lights when leaving the warehouse.