AachenAll electric small elevatorTeach you how to maintain

announcer:hp935HP175192871 release time:2024-02-06 10:50:56

Electric elevators used in various places.

With the continuous improvement of urbanization level in China, the number of high-rise buildings in urban areas has sharply increased, and the height of buildings has also continued to grow. This has created a demand for high-altitude lifting platform vehicles. Therefore, in order to meet the needs of the domestic market and the public, efforts will inevitably be made to design and produce high-altitude lifting platform vehicles.

Aachen.The detailed reason why water cannot be used to flush the hydraulic station is that doing so will corrode the oil tank in the hydraulic station, and once water is mixed in the hydraulic station, the damage to the hydraulic system is very large. Therefore, it will simply form pipeline corrosion, water vaporization, and other phenomena that can cause adverse effects or results for hydraulic electric elevators. Therefore, it is necessary to prevent such actions to ensure the normal operation and service life of the hydraulic station.

Setting requirements: The installation and dismantling workers, electricians, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, and record the inspection results.

Later,AachenSelf propelled electric elevator, when there is a major malfunction of the lifting platform it should be repaired by professional personnel as soon as possible. After the malfunction occurs, personnel and property losses.

With the continuous improvement of urbanization level in China, the number of high-rise buildings in urban areas has sharply increased, and the height of buildings has also continued to grow. This has created a demand for high-altitude lifting platform vehicles. Therefore, in order to meet the needs of the domestic market and the public, efforts will inevitably be made to design and produce high-altitude lifting platform vehicles.


AachenAll electric small elevatorTeach you how to maintain



The oil cylinder and sealing components are made of imported components to solve the problem of unstable oil pressure and oil leakage of components for customers.

In addition, when adding hydraulic oil, it is necessary to ensure the quality of the hydraulic oil,AachenElectric scissor lift, as some hydraulic oil manufacturers will choose hydraulic oil with poor quality. Hydraulic oil such as hydraulic lifting platforms not only cannot have any effect on folding arm elevators, but also affects the working efficiency of folding arm electric elevators due to deterioration issues.

The verticality of the guide rail frame should meet the requirements of the specifications.

Online consultation.Setting requirements: For construction electric elevators with foundations installed on roof slabs, floors, or other lower suspended structures, the bearing capacity of the foundation support structure should be checked. Click here to download the construction technical information for free. Basic drainage facilities should be installed.

To ensure safe and reliable braking of the lifting platform and prevent accidents, a hydraulic control one-way valve, also known as a hydraulic lock, is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure. Electrical system explosion-proof button SB1&flash; The rotation of the SB6 motor and the commutation of the explosion-proof electromagnetic directional valve are used to maintain load increase or decrease, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position


AachenAll electric small elevatorTeach you how to maintain



Later when there is a major malfunction of the lifting platform, it should be repaired by professional personnel as soon as possible. After the malfunction occurs, it should not be used again to avoid accidents,AachenSmall electric automatic elevator, personnel and property losses.

Where to sell API.The foundation production and acceptance of electric elevators for foundation construction should comply with the user manual and regulatory requirements.

That's all for a brief introduction to the common types of electric elevators. I hope everyone can have a better understanding of this product. Currently this product is selling well in China, as many places need to use this type of product that has both lifting function and flexible movement. Companies specializing in producing this type of product are now promoting it on a large scale through the internet, Friends in need can directly find the corresponding companies on the internet and have a brief understanding of the models, performance, and price information of these products. They can purchase directly through the internet.

The foundation base or embedded parts should be fully embedded in the concrete foundation plate.

Aachen.Once again, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened, whether the sealing rings are damaged or ineffective, whether there is a lack of hydraulic oil, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors, wiring, and oil cylinder once a week to avoid dust and debris affecting normal operation.

The list of materials for making landing doors is as follows: Table 1: List of materials for making landing doors. Landing doors should be installed at the entrance of each landing station, and the landing doors should function properly.

Setting requirements: The installation and dismantling workers, electricians, and other operators of construction electric elevators should have special construction operations.