PisaCustomized hydraulic lifting platformWhat are the characteristics

announcer:hp695HP135175170 release time:2024-02-29 10:40:52

What are the pressures on lifting platforms? The movement of lifting platforms has always been a concern for us. Our usage scenarios are uncertain, and most of them are part-time workers. Therefore, in order to better attract customers, we are constantly researching mobile lifting platforms to meet different needs. However, for some large logistics or enterprise processing plants, we are still accustomed to using fixed elevators, He has a huge load capacity and strong stability, which is also the use of lifting platforms in China in recent years.

The main structure and purpose of a guide rail elevator: The mechanical part of a guide rail elevator mainly includes three parts: a lifting device, a track device, and a belt changing device. The lifting device is mainly used to suspend the person being lifted, which is the core part of the entire mechanism. The track device is mainly used to provide movement trajectory, bracket, guide mechanism, lifting arm, upper and lower shells, etc. The gear mechanism mainly includes large and small gears, winding pulleys, central shafts, and safety devices composed of stop buckles and torsion springs.

Pisa.During the use of hydraulic elevators, if not properly operated there will always be problems. Many customers have reported that hydraulic elevators sometimes cannot be lifted. If the hydraulic lift pump can continue to work, other issues need to be considered. Below, the editor will explain the reasons for the hydraulic lift pump station not being oiled and solve the reasons for the hydraulic lift pump station not being oiled, as well as the solutions for mobile elevators The analysis of the pump station of hydraulic elevators such as guide rail elevators is as follows: the motor power supply is abnormal or reversed; The solution is to correctly connect the motor power supply or adjust the steering mailbox to ensure there is no hydraulic oil or insufficient oil; The solution is to add hydraulic oil.

Preparation before folding and installation of the elevator. Carefully prepare a special construction plan for installation and provide safety technical disclosure to the installation personnel.

.According to Beijing regulations, the arrival time is within 30 minutes.

The daily maintenance of guide rail type lifting equipment should pay attention to regular inspection and maintenance, eliminate hidden dangers, eliminate faults, and achieve these benefits for improving work efficiency, extending equipment service life, and ensuring the safety performance of the elevator.

Check the hydraulic oil quality and level. When the lifting platform is raised to a high position, the oil becomes sticky, or there are foreign objects such as gravel in the oil, the hydraulic oil should be replaced in a timely manner. The hydraulic system of the lifting platform should be checked for hydraulic and pipeline connections. If the pipeline is damaged it should be replaced immediately; When there is looseness in the connection part, tighten the pipe joint.


PisaCustomized hydraulic lifting platformWhat are the characteristics



What are the installation precautions for elevators? The folding fence and cage of the elevator should be cleaned of the foundation surface, and the foundation bolts should be installed properly. If the construction elevator is installed on the floor, a pad iron must be used below the screws to increase the force surface between the nuts and the floor to reduce the impact of the nuts on the floor; Insert steel plate shims of different thicknesses between the chassis and the foundation stone at the anchor bolts to adjust the verticality of the guide rail frame; Install three standard sections and measure the verticality of the guide rail frame using a theodolite to ensure the verticality of each main pipe in both directions. After adjusting the verticality of the guide rail frame, tighten the four foundation bolts; Adjust the verticality of the fence door frame as above and tighten the remaining anchor bolts; Install the buffer spring; Connect the other half of the fence to the front half with bolts; Adjust the verticality and tighten the anchor bolts as above and release the brake on the motor inside the suspension cage. (For SC200/200 models, first install the suspension cage before installing the drive plate).

When the motor connection of the elevator is incorrect,PisaHydraulic lifting platform supplier, when a coil, coil group, or one phase winding group is connected in reverse, it can cause serious three-phase current imbalance and cause the winding to overheat.

Mobile elevators are generally used in skyscrapers where electric elevators are used, as there is no need to stop midway,PisaHydraulic lifting platform, so fast elevators are needed. First go to the high-rise sky lobby (high-rise elevator lobby, Skylobby) from the ground, and then transfer to the ordinary elevator to the destination. Some new elevators use elevator pre calling systems, which can pre call designated floors in the lobby. These passenger elevators can be decorated beautifully according to customer needs. Some passenger elevators are also equipped with air conditioning and television, while others are set up in the cabin, so that customers can enjoy the scenery outside while riding.

Convenient and efficient.Drain all the hydraulic oil in the oil tank, open the oil tank, take out the oil suction filter, clean it, and return it to the oil tank. Install it in its original position. Fill the fuel tank with new oil.

The correct construction inspection of the airport is to first inspect the foundation to see if there is any water accumulation and to see if the grounding system meets the requirements. We also need to see how the structural bolts of this frame are tightened, and whether there are any cracks in the welds. We need to set them according to the instructions. In mechanical transmission, it can be divided into two types: open type and closed type. Of course, there are also many safety equipment for elevators.

Good stability: The overflow valve can prevent excessive system pressure during upward movement. Emergency manual valve: In case of power failure, it can cause the elevator car to descend to the nearest floor position and open the door. Manual pump: When the system malfunctions, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position; Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops.


PisaCustomized hydraulic lifting platformWhat are the characteristics



In our daily life hydraulic cargo elevators are increasingly widely used and loved by customers. As a lifting tool, the maintenance of hydraulic cargo elevators should not be careless. Below, the editor will introduce the daily maintenance of hydraulic cargo elevators.

project.Preparation before folding and installation of the elevator. Carefully prepare a special construction plan for installation and provide safety technical disclosure to the installation personnel.

Check the starter potential when the lifting table is not raised or the voltage is too low when the motor load is working. Voltage hydraulic range allowed± 10% of the motor does not rotate. Check the motor and circuit. The motor can be reversed to arbitrarily change the two phases in the three-phase line.

Mobile elevators are generally used in skyscrapers where electric elevators are used, so fast elevators are needed. First go to the high-rise sky lobby (high-rise elevator lobby, Skylobby) from the ground, and then transfer to the ordinary elevator to the destination. Some new elevators use elevator pre calling systems, which can pre call designated floors in the lobby. These passenger elevators can be decorated beautifully according to customer needs. Some passenger elevators are also equipped with air conditioning and television, while others are set up in the cabin, so that customers can enjoy the scenery outside while riding.

Pisa.Working at heights is a common practice nowadays, but it also has a certain degree of danger. So people invented hydraulic lifting platforms, which are more convenient to help people complete high-altitude operations. However, people should also pay attention when using hydraulic lifting platforms, otherwise they can easily malfunction, which may lead to serious consequences. So what are the common faults of hydraulic lifting platforms?

The main structure and purpose of a guide rail elevator: The mechanical part of a guide rail elevator mainly includes three parts: a lifting device, a track device, and a belt changing device. The lifting device is mainly used to suspend the person being lifted, which is the core part of the entire mechanism. The track device is mainly used to provide movement trajectory, making operation more smooth. The belt changing device is used to switch tracks when the elevator is about to pass through a door. The internal structure of the lifting device is mainly composed of gear mechanism, bracket, worm gear,PisaType hydraulic lifting platform, guide mechanism, lifting arm, upper and lower shells, etc. The gear mechanism mainly includes large and small gears, winding pulleys central shafts, and safety devices composed of stop buckles and torsion springs.

Construction elevators are commonly used in industrial or construction sites in our daily lives, mainly for transporting people and goods. We can effectively use construction elevators to improve the efficiency of operations and greatly reduce the workload of operators. So, how should we inspect the construction site of construction elevators? You know?