MunichElectric curved arm elevatorSmall negative impact on the environment

announcer:hp935HP175192871 release time:2024-02-21 12:31:15

Setting requirements: The landing door should be standardized and tooled.

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

Munich.Requirements for the operation platform of the construction lowering machine and the setting of the brake reset emergency stop switch: The shutdown device (emergency stop switch) should be able to stop or maintain the electric elevator (including the power driven door) in a non working state

During normal operation,MunichElevator platform electric, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

.The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

Civil engineering advantages: The pit depth of the guide rail type lifting platform is generally around 150-300mm, and the top layer is not affected. It can be customized according to the location and environment.

The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter,MunichSelf propelled electric elevator, explosion-proof electromagnetic directional valve throttle valve, hydraulic control one-way valve, and balance valve causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).


MunichElectric curved arm elevatorSmall negative impact on the environment



Implementing multiple shifts of homework should fill in and submit records according to regulations.

The body in the lateral adjustment device of the driving plate should ensure a compressed state, so that the gear has a certain radial constraint, and ensure that the gear and rack always mesh well throughout the entire operation.

Setting requirements: For construction electric elevators that operate in multiple shifts, the handover system should be implemented, and drivers should fill out the handover record form according to the standard requirements. The driver should conduct a pre shift inspection and confirm that there are no errors before starting the machine for operation.

Create brilliance.Pipeline rupture valve: When the hydraulic system pipeline ruptures and the car stalls and descends, it can automatically cut off the oil circuit and stop descent

The use of standard section connecting bolts should comply with the user manual and specification requirements.

Secondly, for the replacement of hydraulic oil on the lifting platform, it is recommended to replace it every three months. If the frequency of use is not high, and after changing the hydraulic oil, maintain sufficient space,Munich2 ton electric elevator, and ensure that the lifting platform can be lifted to the rated lifting height.


MunichElectric curved arm elevatorSmall negative impact on the environment



High lifting height, using side mounted oil cylinders, stable operation, noise free, easy maintenance, and longer service life.

average method.Use floor doors and cage door devices on construction sites where conditions permit.

Setting requirements: Construction electric elevators should be equipped with a down travel (limit) switch. The down travel (limit) switch should be able to automatically stop the cage running at rated speed before reaching the lower limit switch.

The advantages and disadvantages of several commonly used electric lifting mechanisms are as follows: hydraulic electric lifting mechanisms: using hydraulic technology, smooth lifting and low noise.

Munich.The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

Setting requirements: Before starting work every day and changing shifts, the driver of the construction electric elevator should inspect the construction electric elevator according to the requirements of the user manual and specifications, record the inspection results, and report any problems found to the user unit.

Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.