IrvingElectric elevator mechanismThe shortage of raw materials in the industry

announcer:hp935HP175192871 release time:2024-02-20 12:20:41

The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.

Setting requirements: For construction electric elevators that operate in multiple shifts, the handover system should be implemented, and drivers should fill out the handover record form according to the standard requirements. The driver should conduct a pre shift inspection and confirm that there are no errors before starting the machine for operation.

Irving.Mobile electric elevators are divided into: four wheel mobile lifting platform, two wheel traction lifting platform, car modified lifting platform, manual lifting platform, manual lifting platform, and AC/DC dual purpose lifting platform

To meet the needs of choreographers and choreographers in different plays, different heights of the lifting platform can be used to change the shape of the stage according to the requirements of the choreographers and choreographers,IrvingSimple electric hoist cargo elevator, in order to adapt to the requirements of the plot for the scenery or venue, a better highlighting effect can be achieved in various performances. According to the needs of the plot, special atmosphere and effects can be created. Even simple stage machinery often participates in performance activities, creating unexpected atmosphere and effects according to the needs of the plot. For example, using the low-speed descent of the lifting platform to represent a sunken ship in the sea, making high-altitude operations easier

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

The quality of the standard section should comply with the product manual and specification requirements.


IrvingElectric elevator mechanismThe shortage of raw materials in the industry



The full height landing door should meet the following requirements: the net height of the landing door opening should not be less than 0m. In special circumstances,IrvingElectric pulley elevator, when the net height of the building entrance is less than 0m, it is allowed to lower the height of the lower door opening, but in any case,IrvingMicro electric elevator, the net height of the lower door opening is not less than 8m. (Article 1 of GB26557-2011)

Requirements for the operation platform of the construction lowering machine and the setting of the brake reset emergency stop switch: The shutdown device (emergency stop switch) should be able to stop or maintain the electric elevator (including the power driven door) in a non working state

When the horizontal distance between the edge of the cage and the edge of the landing or between the cage and the landing door is greater than 150mm and there is no effective protection from other structures, the side protection device for the landing entrance should be equipped.

High quality brand.Spiral electric lifting mechanism: With all the functions of a regular lifting platform, the main feature is that the equipment occupies a small foundation pit and has a large stroke. The equipment has a height of only 200-500mm and a travel distance of up to 14m. It is particularly suitable for buildings with stages built on two or more floors due to space constraints.

The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve throttle valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).

The foundation production and acceptance of electric elevators for foundation construction should comply with the user manual and regulatory requirements.


IrvingElectric elevator mechanismThe shortage of raw materials in the industry



When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

Highly recommended.When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

Normal operation starts. Click on this free download of construction technical information. Safety limit devices should be installed on electric elevators for construction with upper and lower limit switches that are sensitive and reliable.

Horizontal lead screw mechanical electricity

Irving.The verticality of the guide rail frame should meet the requirements of the specifications.

Use floor doors and cage door devices on construction sites where conditions permit.

The counterweight guide rail should meet the specification requirements.