WroclawFoot hydraulic lifting platform vehicleHow to protect the system

announcer:hp530HP141750488 release time:2023-12-19 12:13:28

the hydraulic elevator may experience problems with the hydraulic pump

When the hydraulic system malfunctions, valve and hydraulic installation after repairing the hydraulic system, which can easily cause vibration and generate significant noise.

What are the methods for reducing shaking on lifting platforms? Reducing the shaking of the lifting platform can reduce the psychological obstacles of the operators, ensure the smooth progress of the operation,WroclawHydraulic lifting platform cargo elevator, and also greatly help improve safety. Warm reminder: safety, and their working principles vary. Today,WroclawImported hydraulic lifting platform, we will analyze the working principles of elevators. The types of elevators are generally divided into the following: fixed elevators, This type of elevator uses hydraulic oil cylinders and pump stations to transmit power,WroclawElectric lifting platform, in the form of a scissor fork type. According to customer requirements, the length of the support rod for the scissor fork, the number of layers, the angle of the angle axis, and the expansion and contraction of the oil cylinder complete the lifting operation. Its advantages are large load-bearing capacity, stable lifting and high safety.

Wroclaw.The overflow valve cannot be debugged on its own. The reason why hydraulic cargo elevators are slow is mainly due to human factors in the later stage. Therefore, attention should be paid to maintenance and upkeep during use to reduce accidents

Materials enter the production line at one end of the factory building, and the production process ends at the other end of the factory building with multiple separate platforms; This can greatly shorten the distance of material flow in the factory building.

.After 1500 hours of elevator operation, perform minor repairs to the mechanical and electrical systems.

Remember not to overload, overload is the root cause of many faults.

Considering the oil level in the oil tank, when all hydraulic cylinders in the system are extended, the oil level in the oil tank should not be lower than the Z-low oil level, and when the oil cylinders retract, the oil level should not be higher than the Z-high oil level. In fact, most manufacturers have noticed the above issues. The reason for the introduction is that most users can learn more about the equipment itself when using elevators, in order to facilitate equipment maintenance. Hydraulic cargo elevator manufacturers sincerely hope that you choose a legitimate manufacturer when purchasing elevators, The oil pumped out has no pressure. Cleaning method: Replace the gear pump to clean the problem. Reason: Lack of hydraulic oil. Cleaning method: Add enough hydraulic oil to clean the problem. Reason: Circuit open. Cleaning method: Check the button and fuse to clean the problem. Reason: Filter blockage. Cleaning method: Replace or clean the problem. Reason: Support valve or electromagnetic directional valve malfunction. There are two situations: the input voltage of the electromagnetic coil is lack of 220V. The solenoid coil is burnt out and the valve core is stuck. Cleaning method: maintenance or replacement can be used to clean the natural descent of the lifting platform. Reason and cleaning method: one-way valve leakage cleaning method: check the check valve in the valve. Assuming there is dirt on the sealing surface of the check valve. Clean the check valve.

Operating cost advantage: Low failure rate: Due to the use of hydraulic systems and good methods, the failure rate of elevator operation can be reduced to a low level.

The noise and oil level of the elevator oil cylinder are too low. From the air at the connection of the oil filter or joint to the oil, the coupling inside the oil cylinder is loose. The internal fault of the oil cylinder is that the installation of the oil cylinder motor is not concentric. From the motor, the air and oil at the moving shaft are blocked. The oil return pipe of the oil filter is loose, and the air or oil pipe is on the oil surface, Mixing air into the oil to eliminate: The concentricity should be adjusted to within 0.1MM. The coupling should be repaired or the oil pump should be replaced to increase the oil volume above 400mm in the oil filter and joint positions. The rotating shaft sealing ring should be replaced to clean the oil filter screen, filter the oil, lock the return oil pipeline, and extend the return oil pipeline below the oil level. If there is air mixed in the oil or the air in the hydraulic cylinder is not completely discharged, it will cause cavitation under high pressure and cause significant noise. At this point, it is necessary to exhaust the air in a timely manner.

Interpretation and observation.The above are the working principles of three common elevators, and there are also some forms of elevators that are not common, such as cylinder mounted elevators, curved arm elevators, car mounted elevators, etc. Their common feature is the hydraulic principle for operation, because the stability of the hydraulic system can bring better user experience and safer operation to the equipment, which has been favored by many users.

After 10000 hours of operation on the hydraulic lift, major repairs will be carried out to the mechanical and electrical systems.

Check valve leakage: If the natural wear of the check valve exceeds the specified value after long-term use, it will cause leakage. Disassemble and clean the check valve, and replace it if necessary.


WroclawFoot hydraulic lifting platform vehicleHow to protect the system



An inverter can also generate high noise. When the power supply voltage is lower than 85% of the rated voltage, the short circuit ring of the iron core of the device breaks, the surface of the magnetic yoke and armature is skewed, and the device will produce; Buzz&# quo; Noise.

Product range.The guide rail type elevator has a structure of a straight top oil cylinder. The linear operation of the oil cylinder pulls the transmission chain, driving the lifting of the table to complete the operation. The guide rail type elevator is a popular form of cargo elevator in recent years, with the advantages of higher lifting height, stable operation, and simple maintenance compared to the scissor fork type elevator.

In winter, when working outdoors at heights below minus 10 degrees Celsius, heating rest areas should be set up near the construction area if necessary. Heating equipment should be managed by dedicated personnel and attention should be paid to fire prevention.

Due to damage to the gear pump of the lifting cargo elevator equipment and no pressure lifting. Replace the gear pump.

Wroclaw.Oil leakage from the oil cylinder: If it is a problem with the sealing ring, replace the sealing ring. If there are debris or debris on the oil cylinder, it is recommended to replace it with a new one.

Pay attention to checking each steel wire rope for signs of broken wires and loose drums. If it exceeds the relevant rules it is necessary to replace it immediately. The protection of steel wire ropes should strictly follow the rules of GB5144-85.

Introduction to the unloading lifting platform: The unloading lifting platform is a specialized auxiliary equipment used in conjunction with forklifts for cargo loading and unloading. With it, forklifts can directly drive from the ground into the interior of car compartments for batch loading and unloading operations. The warehouse unloading platform products use manual hydraulic power and do not require power supply. Only one person needs to operate to achieve safe and fast loading and unloading of goods. It can reduce a lot of labor, improve the efficiency of loading and unloading operations, speed up the flow of materials, and obtain greater economic benefits.