Stabia CastleElectric elevator lifting 10 metersProspects for the development of simulation technology

announcer:hp935HP175192871 release time:2024-02-29 11:02:24

The L distance depends on the selected wall mount model.

During normal operation, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements, the average deceleration of the suspension cage should not exceed 1g, and the time when the peak deceleration exceeds 5g should not exceed

Steel wire ropes, pulleys, and counterweight steel wire ropes shall comply with the following regulations: the characteristics of steel wire ropes shall comply with the requirements of General Purpose Steel Wire Ropes GB/T20118; Maintenance, wear, deformation, and corrosion of steel wire ropes

.The quality of the standard section should comply with the product manual and specification requirements.

Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

The entrance of each landing platform must be equipped with a landing door, which must open towards the landing platform side, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).

The safety overtravel of limit switches and upper limit switches should comply with regulatory requirements.

The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder returns to the oil tank through the balance valve, hydraulic control one-way valve, throttle valve, and explosion-proof electromagnetic directional valve. To ensure a smooth descent of heavy objects and safe and reliable braking, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure, so that the descent speed does not change due to heavy objects. The throttle valve regulates the flow rate and the ascending and descending speed.

safety requirements .Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

When the wall bracket adopts non matching standard products, effective protective measures should be taken.


Stabia CastleElectric elevator lifting 10 metersProspects for the development of simulation technology



As a material loading and unloading equipment recognized by customers in the lifting platform, the guide rail hydraulic lifting platform is superior in terms of product, civil engineering, and operating costs. The editor of the electric elevator will provide a detailed analysis: the advantages of the product are that the equipment bears a large load, can achieve multiple points, and can be controlled up and down floors to achieve safe use.

Credit guarantee.High lifting height,Stabia Castle6m electric elevator, using side mounted oil cylinders, stable operation, noise free, easy maintenance and longer service life.

The installation position of the lower limit switch. The installation position of the lower limit switch should ensure that the contact plate triggers the switch when the rated load of the suspension cage decreases, causing the suspension cage to stop. At this time,Stabia CastleElectric three wheel car lift, the contact plate should also be close to the triggering of the lower limit switch

The use of a lifting platform as a tool for storing performance blankets soft scenery, etc. In some theaters, there is a soft scenery storage lifting platform located at an appropriate location on the stage for the storage of blankets, soft scenery,Stabia CastleSelf propelled electric elevator, etc.

Stabia Castle.Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.

During normal operation, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

When the landing door is closed the full width of the lifting passage opening should be covered.