SwatpskHydraulic lifting platform manufacturerTechnological innovation ecosystem

announcer:hp530HP141750488 release time:2024-02-20 12:31:01

When using hydraulic elevators, the main causes of noise are mechanical mechanism failures, hydraulic system failures, electrical equipment or component failures, etc. Today, the manufacturer of hydraulic cargo elevators will introduce to you the reasons for the noise generated by hydraulic elevators.

Optional configuration of fixed lifting platform: The fixed lifting platform can be equipped with auxiliary devices according to usage requirements, and can be combined in any combination, such as the safety protection device of the fixed lifting platform; Electrical methods; Form of work platform; Power form, etc. The correct selection of various configurations maximizes the functionality of the lifting platform and achieves effective use.

Swatpsk.A lifting platform is a lifting device that lifts people or goods to a certain height. When vertical conveying is carried out in logistics systems such as factories and automatic warehouses, various flat conveying equipment is often installed on the lifting platform as a connecting device for conveying lines at different heights. Usually driven by hydraulic pressure, it is called a hydraulic lifting platform. In addition to being used for transporting goods at different heights, it is widely used for high-altitude installation maintenance, and other operations.

Reason: Manual pump and gear pump have severe oil leakage. Cleaning method: Replace the oil pump sealing ring to clean it. Reason: Gear pump is damaged,SwatpskMobile elevator hydraulic lifting platform, The oil pumped out has no pressure. Cleaning method: Replace the gear pump to clean the problem. Reason: Lack of hydraulic oil. Cleaning method: Add enough hydraulic oil to clean the problem. Reason: Circuit open. Cleaning method: Check the button and fuse to clean the problem. Reason: Filter blockage. Cleaning method: Replace or clean the problem. Reason: Support valve or electromagnetic directional valve malfunction. There are two situations: the input voltage of the electromagnetic coil is lack of 220V. The solenoid coil is burnt out and the valve core is stuck. Cleaning method: maintenance or replacement can be used to clean the natural descent of the lifting platform. Reason and cleaning method: one-way valve leakage cleaning method: check the check valve in the valve. Assuming there is dirt on the sealing surface of the check valve. Clean the check valve.

.Regularly inspect the hydraulic lifting equipment of the upper and lower materials to ensure the safety of the rail type elevator and the safety of the material supply to the rail type lifting platform.

When disassembling and adjusting the reverse organization of the equipment, attention should be paid to ensuring that the centerline of the reverse organization reducer is parallel to the centerline of the gear, because this platform needs to complete two functions at the same time, which improves the utilization rate of the well surface.

Before installation, the installation personnel should confirm the infrastructure such as the foundation and shaft pay attention to alignment, leveling, and alignment points,SwatpskDouble fork hydraulic lifting platform, and confirm that the foundation meets the requirements before construction.

Good quality. There is air in front of the pilot valve of the elevator overflow valve noise overflow valve. The damping hole on the main valve core of the overflow valve is blocked by oil dirt, and the pilot valve and valve seat are matched without spring deformation or incorrect installation. The remote control port has excessive oil flow,SwatpskCustomized hydraulic lifting platform, low or high hydraulic oil viscosity, and resonance occurs with components in the circuit. Troubleshooting: Strengthen sealing repeatedly adjust the pressure, Make the damping hole unobstructed exhaust and clean the valve body several times, repair or replace the spring, reduce the flow of the remote control port, and other components. The pressure setting of other components should not be similar to the pressure setting of the relief valve. 5. The noise of the elevator pipeline is usually caused by excessive dead bends or loose fixed sleeves in the hydraulic pipeline.

The manufacturer of hydraulic cargo elevators reminds the use of guide rail hydraulic lifting cargo elevators. Guide rail hydraulic lifting cargo elevators: Do not stand within the specified range, draw on the guide rail lifting platform, prohibit any idle personnel from entering the work area, ensure that the work area is free of clothing, and maintain a clean and tidy workplace.

The manufacturer of hydraulic cargo elevators will tell you about the knowledge of specialized lifting platforms for unloading.


SwatpskHydraulic lifting platform manufacturerTechnological innovation ecosystem



Therefore, the wholesale manufacturers of hydraulic elevators remind that there are three main ways to adjust the speed control circuit: throttling speed control circuit: quantitative pump oil supply, using flow valves to adjust the flow in and out of the actuator to achieve speed control; In the volume throttling speed control circuit, the oil is supplied by the pressure limiting variable pump, and the flow rate into the actuator is adjusted by the flow valve to adapt the flow rate of the variable pump to the regulated flow rate of the speed control valve.

property right.After 5000 hours of elevator operation, carry out medium maintenance on the mechanical and electrical systems.

When the hydraulic cargo elevator needs to work, first connect the power supply and press the button to drive the motor of the hydraulic power unit to drive the gear pump. The hydraulic oil forms a certain pressure through the vane pump and passes through the oil filter; Explosion proof electromagnetic directional valve; Throttle valve; Hydraulic control one-way valve; The balance valve enters the lower end of the hydraulic cylinder, causing it to move upwards and lift heavy objects. The hydraulic cylinder moves downwards (i.e. the weight drops), the explosion-proof electromagnetic directional valve of the hydraulic oil enters the upper end of the hydraulic cylinder, and the return oil from the lower end of the hydraulic cylinder passes through the balance valve; Hydraulic control one-way valve; Throttle valve, explosion-proof electromagnetic directional valve.

The noise and oil level of the elevator oil cylinder are too low. From the air at the connection of the oil filter or joint to the oil, the coupling inside the oil cylinder is loose. The internal fault of the oil cylinder is that the installation of the oil cylinder motor is not concentric. From the motor, the air and oil at the moving shaft are blocked. The oil return pipe of the oil filter is loose, and the air or oil pipe is on the oil surface, Mixing air into the oil to eliminate: The concentricity should be adjusted to within 0.1MM. The coupling should be repaired or the oil pump should be replaced to increase the oil volume above 400mm in the oil filter and joint positions. The rotating shaft sealing ring should be replaced to clean the oil filter screen, filter the oil, lock the return oil pipeline, and extend the return oil pipeline below the oil level. If there is air mixed in the oil or the air in the hydraulic cylinder is not completely discharged, it will cause cavitation under high pressure and cause significant noise. At this point, it is necessary to exhaust the air in a timely manner.

Swatpsk.When the hydraulic oil is insufficient, the hydraulic pump will experience suction, causing air to enter the hydraulic oil and producing high noise.

When the hydraulic system malfunctions, the hydraulic elevator may experience problems with the hydraulic pump, motor, valve, and hydraulic installation after repairing the hydraulic system, which can easily cause vibration and generate significant noise.

To consider its capacity, generally mobile equipment takes 2-3 times the high flow rate of pump Z