Stabia CastleSmall hydraulic lifting and levelingHow to maintain 191029

announcer:hp530HP141750488 release time:2024-01-15 11:34:00

After the pre installation is completed, the pre installed equipment should be fixed,Stabia CastleIndoor fixed hydraulic lifting platform, and the positions of cables oil pipes, and components such as the pre installed frame should be confirmed to be correct before reinforcement work can be carried out. Reinforcement requires welding or screws, and separate maintenance of the distribution box is required. The distribution box should have a leakage switch, and the hydraulic cargo elevator construction site should be equipped with a fire extinguisher to prevent welding operations from causing fires. When selecting a leakage switch, it should be suitable for the operating power.

Stabia Castle.In addition, the convenience of the layout is also a very important issue. For example, in areas with large or high waves, there may be layout issues when using a lifting mechanism. At this point, in order to facilitate the arrangement and prevent the hydraulic cargo elevator cylinder from being eroded by waves, a lifting structure should be selected to determine the installation position of the oil shoulder, as the lifting point of the bridge is not in a straight line during the lifting process. Therefore, during the lifting process of the cylinder, the connection between the two ends of the cylinder and other components must be hinged in the same square. In addition, the installation of the hydraulic cargo elevator cylinder must also be determined through comparison and calculation, whether it is the tail lifting ear type, the middle pin shaft type, or the head pin shaft type. The main advantage is that the effective area of the cylinder is large, there may be stability issues with the cylinder, and the cylinder layout may be difficult. The main advantage of the hydraulic cargo elevator lifting mechanism is that it does not have a stable transmission installation frame for height measurement. Therefore, this form can be considered in places with large drops. The sudden deafness oil type on the head can reduce the installation height, but if it is too large, the oil cylinder will experience an increase in force due to the lifting height. Moreover the higher the lifting height, the faster the increase in force, which is not suitable for the use of the oil cylinder. Therefore, when it is too large, the head pin type is not suitable. In order to comprehensively consider the height of the installation bracket and the force on the oil cylinder during the lifting process, an intermediate installation method can be considered, and the installation position can be set at an appropriate height according to calculations.

Regularly check all wires and cables for damage. It is necessary to wrap and replace the damaged parts in a timely manner.

.Remove the hydraulic oil tank filler cap, filter cover, inspection hole, hydraulic oil pipe and other parts to avoid dust when removing the system oil pipe. Clean the disassembled parts before opening them. When disassembling the hydraulic oil tank filler cap, first remove the soil around the tank cap,Stabia CastleHydraulic guide rail lifting platform, loosen the tank cap, and remove any remaining debris from the joint (do not rinse with water to prevent water from seeping into the tank). After confirming cleaning, open the tank cap.

After the pre installation is completed, the pre installed equipment should be fixed, and the positions of cables, oil pipes and components such as the pre installed frame should be confirmed to be correct before reinforcement work can be carried out. Reinforcement requires welding or screws, and the hydraulic cargo elevator after reinforcement has robustness and safety.

Reason: Manual pump and gear pump have severe oil leakage. Cleaning method: Replace the oil pump sealing ring to clean it. Reason: Gear pump is damaged, The oil pumped out has no pressure. Cleaning method: Replace the gear pump to clean the problem. Reason: Lack of hydraulic oil. Cleaning method: Add enough hydraulic oil to clean the problem. Reason: Circuit open. Cleaning method: Check the button and fuse to clean the problem. Reason: Filter blockage. Cleaning method: Replace or clean the problem. Reason: Support valve or electromagnetic directional valve malfunction. There are two situations: the input voltage of the electromagnetic coil is lack of 220V. The solenoid coil is burnt out and the valve core is stuck. Cleaning method: maintenance or replacement can be used to clean the natural descent of the lifting platform. Reason and cleaning method: one-way valve leakage cleaning method: check the check valve in the valve. Assuming there is dirt on the sealing surface of the check valve. Clean the check valve.


Stabia CastleSmall hydraulic lifting and levelingHow to maintain 191029



The installation personnel should confirm and count the equipment details, confirm that there are no omissions in the shipped equipment details, and ensure the smooth progress of the installation process.

Any work carried out at a height of 2 meters or above should be considered as work at height. Any work that can be done in advance on the ground must be done on the ground to minimize high-altitude operations.

Lifting mechanism: The workbench should be ensured to rise and fall smoothly,Stabia CastleFreight elevator type hydraulic lifting platform, and there should be no jumping lifting phenomenon. All moving parts should be flexible when moving, and there should be no jamming devices. The lifting system of the elevator is divided into electric or manual hydraulic systems, and there should be no leakage at all components, and joints.

middleman.Reason: Manual pump and gear pump have severe oil leakage. Cleaning method: Replace the oil pump sealing ring to clean it. Reason: Gear pump is damaged, The oil pumped out has no pressure. Cleaning method: Replace the gear pump to clean the problem. Reason: Lack of hydraulic oil. Cleaning method: Add enough hydraulic oil to clean the problem. Reason: Circuit open. Cleaning method: Check the button and fuse to clean the problem. Reason: Filter blockage. Cleaning method: Replace or clean the problem. Reason: Support valve or electromagnetic directional valve malfunction. There are two situations: the input voltage of the electromagnetic coil is lack of 220V. The solenoid coil is burnt out and the valve core is stuck. Cleaning method: maintenance or replacement can be used to clean the natural descent of the lifting platform. Reason and cleaning method: one-way valve leakage cleaning method: check the check valve in the valve. Assuming there is dirt on the sealing surface of the check valve. Clean the check valve.

There is a phenomenon of self stopping when running up and down. Due to poor contact of the safety protection switch, it is easy for hydraulic cargo elevator manufacturers to cause this problem.

Load bearing capacity: The lifting platform is placed on a horizontal support surface, and the workbench is evenly loaded to 125% of the maximum load capacity. After lifting 100 times, each load-bearing component must not have deformation or cracks.


Stabia CastleSmall hydraulic lifting and levelingHow to maintain 191029



Lifting mechanism: The workbench should be ensured to rise and fall smoothly, and there should be no jumping lifting phenomenon. All moving parts should be flexible when moving and there should be no jamming devices. The lifting system of the elevator is divided into electric or manual hydraulic systems, and there should be no leakage at all components, pipelines, and joints.

Job description.The cylinder head oil seal is too tight or the rod is bent, which can also cause noise during movement due to other forces. At this point, the oil seal or straightening rod must be replaced in a timely manner.

Hydraulic cargo elevators are mainly used for the transportation of high-altitude goods such as factory assembly lines, cargo warehouses, parking lots, docks buildings, logistics, etc. This product can achieve multi-point, interactive interlocking between upper and lower floors, achieving safe use and carrying capacity of 30 tons. The above are the fields in which hydraulic cargo elevators are applied and the characteristics of hydraulic cargo elevators that we want to share with everyone.

Pay attention to checking each steel wire rope for signs of broken wires and loose drums. If it exceeds the relevant rules, it is necessary to replace it immediately. The protection of steel wire ropes should strictly follow the rules of GB5144-85.

Stabia Castle.Materials enter the production line at one end of the factory building, and the production process ends at the other end of the factory building with multiple separate platforms; This can greatly shorten the distance of material flow in the factory building.

. The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder returns to the oil tank through the balance valve, hydraulic control one-way valve, throttle valve, and explosion-proof electromagnetic directional valve. In order to ensure a smooth descent of heavy objects and safe and reliable braking, a balance valve and balance circuit are installed on the return oil circuit to maintain pressure and ensure that the descent speed is not affected by changes in heavy objects. The throttle valve regulates the flow rate and the lifting speed. To ensure safe and reliable braking and prevent accidents, a hydraulic one-way valve, also known as a hydraulic lock, is added to ensure safe self-locking when the hydraulic pipeline bursts. Install an overload sound alarm to distinguish between overload or equipment failure.

There is air in front of the pilot valve of the elevator overflow valve noise overflow valve. The damping hole on the main valve core of the overflow valve is blocked by oil dirt, and the pilot valve and valve seat are matched without spring deformation or incorrect installation. The remote control port has excessive oil flow, low or high hydraulic oil viscosity, repeatedly adjust the pressure, exhaust and clean the valve body several times, Make the damping hole unobstructed, repair or replace the spring, reduce the flow of the remote control port, replace the oil, and other components. The pressure setting of other components should not be similar to the pressure setting of the relief valve. 5. The noise of the elevator pipeline is usually caused by excessive dead bends or loose fixed sleeves in the hydraulic pipeline.