ParksAluminum alloy hydraulic lifting platform5 ways to find faults

announcer:hp530HP141750488 release time:2024-02-29 10:22:21

Next, the hydraulic cargo elevator manufacturer will explain the maintenance of the mechanical equipment of the elevator: the brakes of each organization should be frequently checked and adjusted to ensure the clearance between the brake pads and wheels is sensitive and reliable. On the surface, there should be no dirt present. If there is dirt, it is necessary to wash it off with gasoline or thinner.

Protective device: In case of power or oil circuit failure, there should be a safety rope to prevent the workbench from falling out of control. (Allow controlled descent)

Parks.How to maintain the cleanliness of hydraulic elevators. If more high-quality hydraulic oil is added, it can prevent oil changes or blockage of system components. However, these additives will lose their effectiveness after a period of time.

When the hydraulic oil is insufficient, the hydraulic pump will experience suction, causing air to enter the hydraulic oil and producing high noise.

.The precautions to consider when selecting a hydraulic lift oil tank include: considering the structure of the oil tank, the partition in the traditional oil tank cannot settle dirt. A vertical partition should be installed along the longitudinal axis of the oil tank, with a space left between one end of the partition and the end plate of the oil tank to connect the gaps on both sides of the partition. The inlet and outlet of the hydraulic pump are arranged on both sides of the partition at the disconnected end, so that the distance Z between the inlet and return oil is far, if the legs lack butter, noise will be generated.

The main device does not engage. When this fault occurs, check whether the three-phase power supply is normal,ParksStraight top hydraulic lifting platform,ParksGuide rail elevator, whether the internal and external emergency stop button switches, the electric lock switch are turned on whether the three-phase electrical phase sequence is correct, and whether the relay working indicator light is on.


ParksAluminum alloy hydraulic lifting platform5 ways to find faults



Check valve leakage: If the natural wear of the check valve exceeds the specified value after long-term use, it will cause leakage. Disassemble and clean the check valve, and replace it if necessary.

Check valve leakage, oil pipe check valve leakage. The solution is to carefully check whether the one-way valve is functioning properly. If it is not normal, it is recommended to replace the one-way valve with a new one.

An inverter can also generate high noise. When the power supply voltage is lower than 85% of the rated voltage, the short circuit ring of the iron core of the device breaks, the surface of the magnetic yoke and armature is skewed, dust or rust is poor, and the device will produce; Buzz&# quo; Noise.

Bidding.The lifting platform is a multifunctional heavy loading and unloading mechanical equipment which can be divided into fixed and mobile, guide rail and curved arm types. Fixed types include scissor elevators, chain elevators, loading and unloading platforms, it is necessary to park the car in a timely manner and the warning lights will light up to warn operators when loading and unloading materials. Idle personnel are prohibited from entering the operating range.

When encountering signs of overheating in the electric motor, clean the problem, and continue running. The motor bearings should be smooth and outstanding.


ParksAluminum alloy hydraulic lifting platform5 ways to find faults



New reference wiring diagram 2. Elevator leg noise. Mobile elevators should open the legs before operation. In this case, if the legs lack butter, noise will be generated.

Industry management.When using hydraulic elevators, the main causes of noise are mechanical mechanism failures, hydraulic system failures, electrical equipment or component failures,ParksElectric lifting platform, etc. Today, the manufacturer of hydraulic cargo elevators will introduce to you the reasons for the noise generated by hydraulic elevators.

Low power consumption: Hydraulic elevators are driven by the pressure generated by their own weight, greatly saving energy. Long term improvement of various brand products such as elevator manufacturers, with complete designated products and quality assurance

When encountering signs of overheating in the electric motor, clean the problem, and continue running. The motor bearings should be smooth and outstanding.

Parks. Road noise can also occur if tires are crushed against objects that are prone to noise. The shaking amplitude of the scissor type lifting platform is proportional to its lifting height. The higher the height, the greater the shaking. When using it at a working height of 10 meters, if possible, please use safety protection measures

Separate: Loading and unloading on different platforms.

The precautions to consider when selecting a hydraulic lift oil tank include: considering the structure of the oil tank, the partition in the traditional oil tank cannot settle dirt. A vertical partition should be installed along the longitudinal axis of the oil tank, with a space left between one end of the partition and the end plate of the oil tank to connect the gaps on both sides of the partition. The inlet and outlet of the hydraulic pump are arranged on both sides of the partition at the disconnected end, so that the distance Z between the inlet and return oil is far, The hydraulic oil tank has more heat dissipation effect.