PesackGuide rail chain lifting cargo elevatorQuality improvement

announcer:hp779HP136589660 release time:2023-11-08 10:22:48

The cleanliness of the hydraulic station is an important aspect of the elevator hydraulic station, from a professional perspective, there are relevant rules and requirements. You should refer to the specification manual, so that you can have a correct understanding and know how to achieve better cleanliness.

Goods should be stacked well on the platform, and should not be tilted. When the goods elevator is lifting or lowering beyond the scope of the platform, no one should stand around to watch.

Pesack.Main structure and purpose of guide rail type elevator: The mechanical part of guide rail type elevator mainly includes three parts: lifting device, track device, and belt changing device. The lifting device is mainly used to suspend the lifted person, which is the core part of the entire mechanism. The role of track device is mainly to provide movement trajectory, making operation more smooth. The belt changing device is used to switch tracks when the elevator is about to pass through the door. The internal structure of the lifting device is mainly composed of a gear mechanism, a bracket, a worm gear, a guide mechanism, a lifting arm, upper and lower shells etc. Gear mechanism Gear mechanism mainly includes large and small gears, winding pulley, central shaft, and safety device composed of stop buckle and torsion spring.

Unscrew the screws on the dustproof hole on the outer side of the elevator flange, adjust the PCS system ring to align its side hole with the dustproof hole, and tighten with the hexagon socket. After that, remove the motor shaft key.

.Usage: Scissor fork type fixed lifting platforms are mostly used for goods transportation between height differences in production lines, loading and unloading materials, adjusting the working height during workpiece assembly, feeding materials to loading machines at high altitudes, lifting components during assembly of large equipment, matching storage and loading sites with forklift trucks and other transportation vehicles for rapid loading and unloading of goods, vehicle lifting, fixed three-dimensional parking, and other places.

The cleanliness of the hydraulic station is an important aspect of the elevator hydraulic station, so it should not be taken lightly. Moreover, from a professional perspective, there are relevant rules and requirements. You should refer to the specification manual, so that you can have a correct understanding and know how to achieve better cleanliness.

In addition, it is strictly prohibited to use a hammer during installation to prevent excessive axial or radial force from damaging the bearings or gears. Be sure to tighten the mounting bolts before tightening the tension bolts. Before installation, clean the anti rust oil on the motor input shaft, positioning boss, and elevator connection parts with gasoline or zinc sodium water. Its purpose is to ensure the tightness of the connection and the flexibility of operation, and to prevent unnecessary wear and tear.


PesackGuide rail chain lifting cargo elevatorQuality improvement



It is strictly prohibited for personnel to climb up and down the floors by using the goods elevator privately.

Replace with new oil and do not intermittently use the old oil, with a scissors type mechanical mechanism, easy to maintain,PesackIndustrial cargo elevators, and high bearing capacity. The lifting height is about 10 meters and the load capacity is about 10 tons.

Where can I find it?.Does the cleanliness of the hydraulic station have relevant rules and requirements?

The water cooling of hydraulic stations is generally tubular water cooling, and the type selection is based on the heat load to calculate the heat exchange area, while the air-cooled elevator is conducted using an air cooler, and the heat exchange capacity is calculated based on the heat load. Then the type selection calculation is performed when the flow can be satisfied. Therefore, the two types of cooling are different, and there are significant differences. Long-term lifting and lowering of cargo elevator factory

Unscrew the screws on the dustproof hole on the outer side of the elevator flange, adjust the PCS system ring to align its side hole with the dustproof hole, and tighten with the hexagon socket. After that, remove the motor shaft key.


PesackGuide rail chain lifting cargo elevatorQuality improvement



Before connecting the motor to the elevator, the elevator manufacturer should first make the motor shaft keyway perpendicular to the tightening bolt. To ensure uniform stress,PesackGuide rail type lifting cargo elevator, first screw on the mounting bolts at any diagonal position, but do not tighten them. Then screw on the other two mounting bolts at diagonal positions, and the use of elevators and lifting platforms shall be checked

Sincere service.Safety performance: The lifting structure is made of high-strength manganese steel rectangular tubes tighten the tightening bolts. All tightening bolts shall be fixed with a torque wrench according to the indicated fixed torque data, with a scissors type mechanical mechanism, easy to maintain, strong stability, and high bearing capacity. The lifting height is about 10 meters, and the load capacity is about 10 tons.

Replace with new oil and do not intermittently use the old oil, otherwise the moving parts in the system will accelerate wear.

Test the goods elevator every day to see if it can operate normally.

Pesack.In addition, it is strictly prohibited to use a hammer during installation to prevent excessive axial or radial force from damaging the bearings or gears. Be sure to tighten the mounting bolts before tightening the tension bolts. Before installation, clean the anti rust oil on the motor input shaft, positioning boss, and elevator connection parts with gasoline or zinc sodium water. Its purpose is to ensure the tightness of the connection and the flexibility of operation, and to prevent unnecessary wear and tear.

Prepare the foundation according to the foundation plan, pay attention to alignment, leveling, and alignment, or muddy roads. The bottom and some gaps and indoor floors are prone to sludge accumulation. If the owner does not clean them in a timely manner,PesackSimple lifting cargo elevator requires, this can cause moisture to hide. Therefore, activities in the outer edges of wheel hubs, doors, bottom corners of tree trunks, key holes and wiper brackets, as well as other areas, should be regularly inspected, and the drainage holes in the doors and various parts should be kept unblocked to ensure that the car seat covers, such as humidity, carpets, and floors, prevent rust from forming parts.