AlmeroSimple lifting cargo elevatorExecutive agency

announcer:hp779HP136589660 release time:2024-04-04 10:16:07

Safety performance: The lifting structure is made of high-strength manganese steel rectangular tubes, with a scissors type mechanical mechanism, easy to maintain, strong stability, and high bearing capacity. The lifting height is about 10 meters, and the load capacity is about 10 tons.

The brake operators of each mechanism on the equipment should regularly check and adjust the clearance of the brake shoe and brake wheel, ensuring flexibility and reliability. Long term improvement of the elevator factory, a 20 year old brand with competitive prices and guaranteed quality!

Almero.How to solve the problem of oil pipe leakage due to the sinking of the elevator? It may be caused by damaged seals or cracks in the oil pipe, resulting in a pressure drop and inability to support the oil pipe to a large height.

The purpose of hydraulic lifting platform Users can choose the power mode and configuration according to their own scope of use: power systems include: DC power supply, single-phase or three-phase power supply, diesel engine.

.Is the water cooling and air cooling of the hydraulic station the same?

'Using the elevator is not about maintaining and overhauling the equipment after it has failed. It is important to maintain the equipment in accordance with the correct maintenance and overhaul. First do the preparatory work to eliminate all possible fault problems and accidents. I hope that today's summary of knowledge points by the editor can help everyone.'.

Unscrew the screws on the dustproof hole on the outer side of the elevator flange, adjust the PCS system ring to align its side hole with the dustproof hole, and tighten with the hexagon socket. After that, remove the motor shaft key.


AlmeroSimple lifting cargo elevatorExecutive agency



Goods should be stacked well on the platform, and should not be tilted. When the goods elevator is lifting or lowering beyond the scope of the platform, no one should stand around to watch.

The solenoid valve on the motor should not be adjusted randomly. The solenoid valve is pre adjusted before leaving the factory, and random adjustment can easily cause internal pressure to increase or decrease, which in severe cases can shorten the service life of the motor.

Knowledge popularization and superior performance of scissor fork type fixed lifting platform: equipped with safety devices to prevent overloading of the lifting platform; Equipped with a protection valve to prevent hydraulic oil pipe from cracking; Equipped with an emergency lowering device for sudden power failure; The doors of the upper and lower floors are equipped with safety devices that interlock with the system.

Project scope.Secondly, there should be no dirt on the friction surface. If there is any dirt, gearbox, and other parts of the equipment, must be tested according to the requirements in the table; Correct maintenance of the hydraulic guide rail elevator: Regularly inspect the wire ropes at various parts for broken wires and looseness. If any such phenomenon is found, replace it in a timely manner. The maintenance of the wire ropes must be carried out in strict accordance with the specifications; Check the connection condition of each part according to the braking rules and regulations. If there is any looseness, tighten it in a timely manner. Check the tightness of the connecting bolts of the equipment when the body is under pressure. All connecting shafts should be equipped with cotter pins; Check whether the operation of each mechanism is normal, whether there are noises and faults according to regulations,AlmeroTwo ton guide rail type cargo elevator, and promptly remove all faults; When installing, disassembling,AlmeroBody guide rail type cargo elevator, and adjusting the rotating mechanism of the equipment, it is important to note that the reducer and the gear center line should be parallel, and the meshing clearance should be appropriate; Regularly conduct a comprehensive inspection of the equipment to see if there is any damage to the wires and cables,AlmeroLifting cargo elevator, and if there is overheating of the motor. Replace the motor in a timely manner and eliminate the fault before continuing operation; Ensure that the bearings, boxes distribution boxes, and brushes of the motor are kept clean, install a separate distribution box. When using the distribution box, the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency the selection of the leakage switch should be compatible with the frequency converter.

Fixed elevator is a transportation equipment that directly lifts and loads goods from the ground. It is mainly used for goods transportation between height differences in production lines, material loading and unloading, component lifting during assembly of large equipment, fixed three-dimensional parking, and other places. So what is the new price for fixed elevators?


AlmeroSimple lifting cargo elevatorExecutive agency



To ensure excellent power supply at the installation site, install a separate distribution box. When using the distribution box, the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.

Quality improvement.Systems: explosion-proof electronic control system, remote control system, PIC system.

Manual hydraulic platform classification: Manual hydraulic lifting platform vehicles can be divided into manual hydraulic handling platform vehicles, manual hydraulic stacking platform vehicles, and manual hydraulic shear type platform vehicles.

In addition, it is strictly prohibited to use a hammer during installation to prevent excessive axial or radial force from damaging the bearings or gears. Be sure to tighten the mounting bolts before tightening the tension bolts. Before installation, clean the anti rust oil on the motor input shaft, positioning boss, and elevator connection parts with gasoline or zinc sodium water. Its purpose is to ensure the tightness of the connection and the flexibility of operation and to prevent unnecessary wear and tear.

Almero.The anti rust work of aerial vehicles is generally something that needs attention when they have not been used for a long time. How should we protect the body of aerial vehicles from corrosion? This is actually a simple matter of not having to spend money on anti-corrosion at the repair station. As long as we car owners use some materials they can find on their own, we can achieve this. At the same time, paying attention to driving habits can ensure that high-altitude work vehicles do not rust. Here are a few points for reference.

Precautions for using guide rail type elevators: Overloading and transporting flammable and explosive products are strictly prohibited.

The water cooling of hydraulic stations is generally tubular water cooling, and the type selection is based on the heat load to calculate the heat exchange area, while the air-cooled elevator is conducted using an air cooler, and the heat exchange capacity is calculated based on the heat load. Then, the type selection calculation is performed when the flow can be satisfied. Therefore, the two types of cooling are different, and there are significant differences. Long-term lifting and lowering of cargo elevator factory