SuwokiFloor to floor cargo elevatorRelease signal

announcer:hp779HP136589660 release time:2024-01-19 14:44:30

The motor winding is short-circuited. When a short circuit fault occurs in the motor winding, the short circuit current is much larger than the normal working current, which increases the copper loss of the winding, causing the winding to overheat or even burn out.

Safety performance: The lifting structure is made of high-strength manganese steel rectangular tubes, with a scissors type mechanical mechanism, easy to maintain, strong stability, and high bearing capacity. The lifting height is about 10 meters, and the load capacity is about 10 tons.

Suwoki.The daily maintenance of guide rail type lifting equipment should pay attention to regular inspection and maintenance, eliminate hidden dangers, and eliminate faults. Doing so is beneficial to improving work efficiency, extending the service life of the equipment, and ensuring the safety performance of the elevator.

Outriggers: mechanical outriggers, hydraulic outriggers, ordinary hand cranking outriggers and pull-out outriggers.

.Several types: motor winding open circuit. When one phase of the motor winding is open circuit, it will cause three-phase current imbalance and cause the motor to overheat.

Incorrect connection of the elevator motor When a coil, coil group, or one phase winding group is connected inversely, it can cause a serious imbalance in the three-phase current and cause the winding to overheat.

Before installing the elevator, confirm whether the motor and the elevator are intact, and strictly check whether the dimensions of each part connecting the motor and the elevator match. Here are the dimensions and fit tolerances of the positioning boss, input shaft, and elevator groove of the motor.


SuwokiFloor to floor cargo elevatorRelease signal



Different. (Specific bearing capacity and lifting height can be designed and customized according to user requirements)

Overview of manual hydraulic platform: Manual hydraulic platform is a small lifting mechanical platform, lifting, moving, and placing of items, as well as handling small valuable items. The product has a generous and beautiful appearance, solid structure, stability, safety and reliability, and its performance and service life have reached the advanced level of the same equipment. Currently, the mainstream of the market is hydraulic driven lifting. Due to its compact size and convenient mobility,SuwokiGuide rail type lifting cargo elevator, it is widely used in logistics and transportation, warehouse management, libraries, supermarkets, and ordinary small equipment manufacturing industries.

Regardless of whether it is used outdoors or indoors, it is inevitable that some small problems will occur after a long period of time. At this time, what we should do is to maintain and maintain the elevator. How to follow the steps correctly becomes a difficult problem. Let me explain it to you.

Inspection standard.Corrosion prevention measures for the body of aerial work vehicles Attention to small scratches The paint surface of aerial work vehicles often corrodes. In addition to common collisions, scratches, and small rocks on the drive tire, there can also be a paint peeling point that can cause a small rust over time. Because most of these scars are small and easy to ignore. Therefore, regularly inspect the engine compartment lid and surrounding areas, and once found, and the type selection is based on the heat load to calculate the heat exchange area, while the air-cooled elevator is conducted using an air cooler, and the heat exchange capacity is calculated based on the heat load. Then the type selection calculation is performed when the flow can be satisfied. Therefore, and there are significant differences. Long-term lifting and lowering of cargo elevator factory

Secondly the two types of cooling are different, there should be no dirt on the friction surface. If there is any dirt, it should be washed off with gasoline or thinner; The reduction gearbox, gearbox, external meshing gear, and other parts of the equipment, as well as the hydraulic oil, must be tested according to the requirements in the table; Correct maintenance of the hydraulic guide rail elevator: Regularly inspect the wire ropes at various parts for broken wires and looseness. If any such phenomenon is found, replace it in a timely manner. The maintenance of the wire ropes must be carried out in strict accordance with the specifications; Check the connection condition of each part according to the braking rules and regulations. If there is any looseness, tighten it in a timely manner. Check the tightness of the connecting bolts of the equipment when the body is under pressure. All connecting shafts should be equipped with cotter pins; Check whether the operation of each mechanism is normal, whether there are noises and faults according to regulations, and promptly remove all faults; When installing, disassembling, and adjusting the rotating mechanism of the equipment, it is important to note that the reducer and the gear center line should be parallel and the meshing clearance should be appropriate; Regularly conduct a comprehensive inspection of the equipment to see if there is any damage to the wires and cables, and if there is overheating of the motor. Replace the motor in a timely manner and eliminate the fault before continuing operation; Ensure that the bearings, boxes, distribution boxes, and brushes of the motor are kept clean, and that the travel switch points of each safety device must be safe and reliable.


SuwokiFloor to floor cargo elevatorRelease signal



Connect the motor to the elevator naturally. During connection, it must be ensured that the concentricity of the elevator output shaft and the motor input shaft is consistent, and that the outer flanges of the two are parallel. Inconsistent centering can cause the motor shaft to break or the elevator gear to wear.

Click to view.Corrosion prevention measures for the body of aerial work vehicles Attention to small scratches The paint surface of aerial work vehicles often corrodes. In addition to common collisions, and small rocks on the drive tire, there can also be a paint peeling point that can cause a small rust over time. Because most of these scars are small and easy to ignore. Therefore regularly inspect the engine compartment lid and surrounding areas, and once found,SuwokiFixed lifting cargo elevator, go to a professional beauty shop for processing in a timely manner.

What is the solution to the problem of rust on the surface of the spiral elevator? Sandpaper has a large loss on the spiral elevator itself. Specializing in products, renewable resources business, including: elevator factory

In addition, it is strictly prohibited to use a hammer during installation to prevent excessive axial or radial force from damaging the bearings or gears. Be sure to tighten the mounting bolts before tightening the tension bolts. Before installation, clean the anti rust oil on the motor input shaft, positioning boss, and elevator connection parts with gasoline or zinc sodium water. Its purpose is to ensure the tightness of the connection and the flexibility of operation, and to prevent unnecessary wear and tear.

Suwoki.Incorrect connection of the elevator motor When a coil, coil group, it can cause a serious imbalance in the three-phase current and cause the winding to overheat.

Hydraulic pump station: domestic lifting platform dedicated pump station, Italian imported pump station with external protective devices: organ m type, mesh type,Suwoki5-ton factory lift cargo elevator, and iron plate sealed type.

Scissor type fixed lifting platform is a transportation and loading equipment that transports goods from one height to another. After operation, the platform is level with the ground, without occupying ground space and affecting passage passage.