Gdansk8-meter cargo elevatorPositioning method

announcer:hp779HP136589660 release time:2024-03-27 09:25:45

Motor connection error. When the triangular connection motor is mistakenly connected into a star shape, the motor still operates with full load, and the current flowing through the stator winding exceeds the rated current, leading to the motor stopping itself. If the stopping time is slightly longer and the power supply is not cut off, but also burned. When a star connected motor is mistakenly connected into a triangle, or when several coil groups are connected in series into a single branch, the motor is mistakenly connected into two branches in parallel, both the windings and the iron core will overheat, and in severe cases, the windings will be burned.

This fixed lifting device can also be used inside a warehouse, such as lifting a certain layer of the warehouse to transport goods or personnel to a designated warehouse location.

Gdansk.The daily maintenance of guide rail type lifting equipment should pay attention to regular inspection and maintenance, and eliminate faults. Doing so is beneficial to improving work efficiency, extending the service life of the equipment, and ensuring the safety performance of the elevator.

The hydraulic lifting platform can be divided into four wheeled mobile type, two wheeled traction type, vehicle modified type, vehicle type, auxiliary self-propelled type, and the lifting height varies from a meter to 1 meter.

.To ensure excellent power supply at the installation site, install a separate distribution box. When using the distribution box, the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.

The common types of elevators will be briefly introduced here. I hope you can have a better understanding of this product. Currently, this product can be said to be sold well in China,GdanskCargo elevator, because many places need to use this kind of product with lifting function and flexible movement. Now, companies specializing in producing this type of product combine with extensive external publicity on the Internet Friends in need can directly find the corresponding company on the Internet, and then have a brief understanding of the model, performance, and price information of these products. They can purchase directly through the Internet.

Scissor type fixed lifting platform is a transportation and loading equipment that transports goods from one height to another. After operation, the platform is level with the ground, and should not be tilted. When the goods elevator is lifting or lowering beyond the scope of the platform, no one should stand around to watch.

Overview of manual hydraulic platform: Manual hydraulic platform is a small lifting mechanical platform, mainly used for small range lifting, lifting moving, and placing of items, as well as handling small valuable items. The product has a generous and beautiful appearance, solid structure, stability, safety and reliability, and its performance and service life have reached the advanced level of the same equipment. Currently the mainstream of the market is hydraulic driven lifting. Due to its compact size and convenient mobility, it is widely used in logistics and transportation, warehouse management, supermarkets, and ordinary small equipment manufacturing industries.

Motor connection error. When the triangular connection motor is mistakenly connected into a star shape, the motor still operates with full load, and the current flowing through the stator winding exceeds the rated current,GdanskTwo ton guide rail type cargo elevator, the winding will not only be severely overheated, but also burned. When a star connected motor is mistakenly connected into a triangle, or when several coil groups are connected in series into a single branch the motor is mistakenly connected into two branches in parallel, both the windings and the iron core will overheat, and in severe cases, the windings will be burned.

The cheapest.Precautions for using guide rail type elevators: Overloading and transporting flammable and explosive products are strictly prohibited.

It is strictly prohibited for personnel to climb up and down the floors by using the goods elevator privately.

Unscrew the screws on the dustproof hole on the outer side of the elevator flange, adjust the PCS system ring to align its side hole with the dustproof hole, and tighten with the hexagon socket. After that, remove the motor shaft key.


Gdansk8-meter cargo elevatorPositioning method



After the goods are transported, clean the platform.

Where can I find it?.Is the water cooling and air cooling of the hydraulic station the same?

3. High pressure water abrasive rust removal. A type of spiral elevator that utilizes the impact of high-pressure water jets and abrasive to polish and remove rust. It has the advantage of causing little damage to the material, but water can cause certain damage to electronic equipment. It is suitable for the detachable type of spiral elevator.

The load of this series of products is divided into 0.1 to 0.8 tons, and can also be customized according to user requirements with a load of up to 10 tons.

Gdansk.The load of this series of products is divided into 0.1 to 0.8 tons, and can also be customized according to user requirements,GdanskHydraulic lifting cargo elevator, with a load of up to 10 tons.

Frequently check for water accumulation and humidity. It is inevitable for aerial vehicles to drive in rainy and snowy weather, or muddy roads. The bottom and some gaps and indoor floors are prone to sludge accumulation. If the owner does not clean them in a timely manner, this can cause moisture to hide. Therefore, activities in the outer edges of wheel hubs, doors, bottom corners of tree trunks, key holes, and wiper brackets, as well as other areas, should be regularly inspected, and the drainage holes in the doors and various parts should be kept unblocked to ensure that the car seat covers, such as humidity, carpets, and floors, prevent rust from forming parts.

To ensure excellent power supply at the installation site, install a separate distribution box. When using the distribution box, the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.