qinghuangdaoGuide rail chain lifting cargo elevatorAnti-rust maintenance coating anti-rust oil

announcer:hp779HP136589660 release time:2024-03-22 11:54:27

Secondly, there should be no dirt on the friction surface. If there is any dirt, it should be washed off with gasoline or thinner; The reduction gearbox, gearbox, external meshing gear, and other parts of the equipment, as well as the hydraulic oil, must be tested according to the requirements in the table; Correct maintenance of the hydraulic guide rail elevator: Regularly inspect the wire ropes at various parts for broken wires and looseness. If any such phenomenon is found, replace it in a timely manner. The maintenance of the wire ropes must be carried out in strict accordance with the specifications; Check the connection condition of each part according to the braking rules and regulations. If there is any looseness, tighten it in a timely manner. Check the tightness of the connecting bolts of the equipment when the body is under pressure. All connecting shafts should be equipped with cotter pins; Check whether the operation of each mechanism is normal, whether there are noises and faults according to regulations, and promptly remove all faults; When installing, disassembling, and adjusting the rotating mechanism of the equipment,qinghuangdaoCustomized cargo elevator, it is important to note that the reducer and the gear center line should be parallel, and the meshing clearance should be appropriate; Regularly conduct a comprehensive inspection of the equipment to see if there is any damage to the wires and cables, and if there is overheating of the motor. Replace the motor in a timely manner and eliminate the fault before continuing operation; Ensure that the bearings, boxes, distribution boxes, and brushes of the motor are kept clean, and that the travel switch points of each safety device must be safe and reliable.

Systems: explosion-proof electronic control system, remote control system, PIC system.

qinghuangdao.The opening system of the manual hydraulic stacking platform car can be divided into pedal type and manual control type for selection, which is simple and easy to operate. The vehicle model is divided into fixed and mobile forks, supermarket retail goods placement, and extraction.

Is the water cooling and air cooling of the hydraulic station the same?

.It is strictly prohibited for personnel to climb up and down the floors by using the goods elevator privately.

Secondly, there should be no dirt on the friction surface. If there is any dirt, it should be washed off with gasoline or thinner; The reduction gearbox, external meshing gear, and other parts of the equipment as well as the hydraulic oil, must be tested according to the requirements in the table; Correct maintenance of the hydraulic guide rail elevator: Regularly inspect the wire ropes at various parts for broken wires and looseness. If any such phenomenon is found, replace it in a timely manner. The maintenance of the wire ropes must be carried out in strict accordance with the specifications; Check the connection condition of each part according to the braking rules and regulations. If there is any looseness, tighten it in a timely manner. Check the tightness of the connecting bolts of the equipment when the body is under pressure. All connecting shafts should be equipped with cotter pins; Check whether the operation of each mechanism is normal, whether there are noises and faults according to regulations, and promptly remove all faults; When installing, disassembling, and adjusting the rotating mechanism of the equipment, it is important to note that the reducer and the gear center line should be parallel, and the meshing clearance should be appropriate; Regularly conduct a comprehensive inspection of the equipment to see if there is any damage to the wires and cables, and if there is overheating of the motor. Replace the motor in a timely manner and eliminate the fault before continuing operation; Ensure that the bearings, boxes, distribution boxes, and that the travel switch points of each safety device must be safe and reliable.

The cleanliness of the hydraulic station is an important aspect of the elevator hydraulic station, so it should not be taken lightly. Moreover, there are relevant rules and requirements. You should refer to the specification manual, so it should not be taken lightly. Moreover from a professional perspective, there are relevant rules and requirements. You should refer to the specification manual, so that you can have a correct understanding and know how to achieve better cleanliness.

Manual hydraulic lifting platform application Manual hydraulic platform performance: The manual hydraulic platform truck is made of high-strength steel, with a reasonable and compact design structure, safety, stability, and reliability. It is equipped with a safety valve, a fully sealed oil cylinder, and a manual hydraulic system for lifting and lowering making it easy to operate. Equipped with a guide wheel to save the operator's physical strength, and can protect the load wheel and pallet load wheel. Unique hydraulic pump design, the pump is simple and designed to maintain an ideal height for pipeline loading and unloading operations; The unique design concept makes the operator's operation simple and convenient.

Safety performance: The lifting structure is made of high-strength manganese steel rectangular tubes, with a scissors type mechanical mechanism, strong stability, and high bearing capacity. The lifting height is about 10 meters, and the load capacity is about 10 tons.

Economic management.Does the cleanliness of the hydraulic station have relevant rules and requirements?

Frequently check for water accumulation and humidity. It is inevitable for aerial vehicles to drive in rainy and snowy weather or muddy roads. The bottom and some gaps and indoor floors are prone to sludge accumulation. If the owner does not clean them in a timely manner, this can cause moisture to hide. Therefore, activities in the outer edges of wheel hubs, doors,qinghuangdaoSimple lifting cargo elevator requires, bottom corners of tree trunks, key holes, and wiper brackets, as well as other areas, should be regularly inspected, and the drainage holes in the doors and various parts should be kept unblocked to ensure that the car seat covers, such as humidity, carpets, and floors, prevent rust from forming parts.

This fixed lifting device can also be used inside a warehouse, such as lifting a certain layer of the warehouse to transport goods or personnel to a designated warehouse location.


qinghuangdaoGuide rail chain lifting cargo elevatorAnti-rust maintenance coating anti-rust oil



For guideway elevators installed outdoors, they are often exposed to rain and sunlight, so special attention should be paid to regular maintenance and inspection to avoid accidents.

Direct labor.Before connecting the motor to the elevator, the elevator manufacturer should first make the motor shaft keyway perpendicular to the tightening bolt. To ensure uniform stress, first screw on the mounting bolts at any diagonal position, but do not tighten them. Then screw on the other two mounting bolts at diagonal positions, and then tighten the four mounting bolts one by one. After that, tighten the tightening bolts. All tightening bolts shall be fixed with a torque wrench according to the indicated fixed torque data, and the use of elevators and lifting platforms shall be checked

After careful inspection, it was found that there were two main causes: loss of hydraulic pressure, and leakage of hydraulic valves or seals.

Systems: explosion-proof electronic control system, remote control system, PIC system.

qinghuangdao.Safety performance: The lifting structure is made of high-strength manganese steel rectangular tubes, with a scissors type mechanical mechanism, easy to maintain, strong stability, and high bearing capacity. The lifting height is about 10 meters, and the load capacity is about 10 tons.

Precautions for using guide rail type elevators: Overloading and transporting flammable and explosive products are strictly prohibited.

To ensure excellent power supply at the installation site, install a separate distribution box. When using the distribution box the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.