Nai meihengHydraulic lifting platformHow to improve the accuracy to facilitate the solution of manufacturing difficulties

announcer:hp530HP141750488 release time:2024-03-18 11:20:50

The oil pumped out has no pressure. Cleaning method: Replace the gear pump to clean the problem. Reason: Lack of hydraulic oil. Cleaning method: Add enough hydraulic oil to clean the problem. Reason: Circuit open. Cleaning method: Check the button and fuse to clean the problem. Reason: Filter blockage. Cleaning method: Replace or clean the problem. Reason: Support valve or electromagnetic directional valve malfunction. There are two situations: the input voltage of the electromagnetic coil is lack of 220V. The solenoid coil is burnt out and the valve core is stuck. Cleaning method: maintenance or replacement can be used to clean the natural descent of the lifting platform. Reason and cleaning method: one-way valve leakage cleaning method: check the check valve in the valve. Assuming there is dirt on the sealing surface of the check valve. Clean the check valve.

Hydraulic elevator manufacturers remind us that the basic principle of the hydraulic elevator speed control circuit is that the system often needs to adjust the movement speed of the hydraulic cylinder and hydraulic motor to adapt to the working cycle needs of the main machine. The speed of hydraulic cylinders and hydraulic motors depends on the displacement and input flow rate. It can be seen that changing the flow rate or displacement can affect the speed of the cylinder and motor.

Nai meiheng.When the hydraulic cargo elevator needs to work, first connect the power supply and press the button to drive the motor of the hydraulic power unit to drive the gear pump. The hydraulic oil forms a certain pressure through the vane pump and passes through the oil filter; Explosion proof electromagnetic directional valve; Throttle valve; Hydraulic control one-way valve; The balance valve enters the lower end of the hydraulic cylinder, causing it to move upwards and lift heavy objects. The hydraulic cylinder moves downwards (i.e. the weight drops), the explosion-proof electromagnetic directional valve of the hydraulic oil enters the upper end of the hydraulic cylinder, and the return oil from the lower end of the hydraulic cylinder passes through the balance valve; Hydraulic control one-way valve; Throttle valve, explosion-proof electromagnetic directional valve.

Oil leakage is a common malfunction. Due to loose joints or damaged sealing rings, oil leakage may occur. Therefore, this fault can be solved by tightening the oil leakage joint or replacing the damaged sealing ring.

.Selection of the location of the loading and unloading lifting platform In order to reduce the cost of material handling, the location of the platform should be selected to minimize the distance of the handling tools and vehicles in the factory. It is much easier to move a fully loaded transport vehicle to a designated location outside the building than to transport the loaded materials one by one to the designated location indoors. When selecting a platform location, full consideration should be given to the production process and operational needs of the factory. There are two modes of platform layout: merging: loading and unloading on the same platform.

Reason: The lowering valve is not tightly closed. Cleaning method: Check if the lowering valve is powered on. If there is no power supply,Nai meihengHydraulic automatic lifting platform, clear the malfunction of the lowering valve itself or replace the lowering valve. It is necessary to keep the valve of the lowering valve clean and flexible.

The development of elevators is at its peak, as many manufacturers have chosen more multi-story buildings to fully utilize the site, it will not cause lifting. At this point you only need to add enough hydraulic oil to run.

When loading and unloading goods at the dock, hydraulic cargo elevators are often used. What are the advantages and disadvantages of hydraulic cargo elevators compared to electric cargo elevators?

Regularly check all wires and cables for damage. It is necessary to wrap and replace the damaged parts in a timely manner.

How many?.An inverter can also generate high noise. When the power supply voltage is lower than 85% of the rated voltage, the short circuit ring of the iron core of the device breaks, the surface of the magnetic yoke and armature is skewed, dust or rust is poor, and the device will produce; Buzz&# quo; Noise.

. The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder returns to the oil tank through the balance valve, hydraulic control one-way valve, throttle valve, and explosion-proof electromagnetic directional valve. In order to ensure a smooth descent of heavy objects and safe and reliable braking, a balance valve and balance circuit are installed on the return oil circuit to maintain pressure and ensure that the descent speed is not affected by changes in heavy objects. The throttle valve regulates the flow rate and the lifting speed. To ensure safe and reliable braking and prevent accidents a hydraulic one-way valve, also known as a hydraulic lock, they should be promptly cleaned up.


Nai meihengHydraulic lifting platformHow to improve the accuracy to facilitate the solution of manufacturing difficulties



When the hydraulic oil is insufficient, the hydraulic pump will experience suction, causing air to enter the hydraulic oil and producing high noise.

install.After 5000 hours of elevator operation, carry out medium maintenance on the mechanical and electrical systems.

Many operating factories often require the use of hydraulic cargo elevators, which can be lifted and lowered, making it very convenient to use. Many people do not know the knowledge of hydraulic cargo elevator lifting and adjustment. If they understand this knowledge, it will be helpful for future maintenance. The power unit of the fixed chain elevator for hydraulic lifting of cargo elevators drives the hydraulic oil to generate pressure causing the oil cylinder to move back and forth to drive the lifting platform, thus achieving the adjustment of lifting speed. The power unit adjustment, is composed of the power unit and the oil cylinder. The power unit is manufactured with four outlet holes, which can be adjusted in size to increase or decrease the hydraulic oil flow rate of the oil cylinder, Adjustable motor speed or electro-hydraulic proportional valve to adjust hydraulic oil flow rate; The longer the oil pipe and hydraulic oil pipe, the longer the rise time. So during installation, try to minimize the length of the pipeline within the allowable range of the design; On the basis of adjusting the power device, the size of the oil pipeline can also be adjusted, and corresponding adjustments can be made while ensuring that the equipment meets normal demand and safety.

Hydraulic lift cargo elevators belong to high-altitude work equipment. Small shaking of the scissor type structure is normal,Nai meihengElectric lifting platform, but excessive deviation is a symptom. It is necessary to find the cause and make correct judgments in a timely manner. Generally speaking, operations above 8 meters are generally allowed. Due to its own weight, devices above this height begin to vibrate in different ranges. The vibration range depends on factors such as weight, lifting height, and intensity of high-altitude operations.

Nai meiheng.The characteristics of the platform include reliable hydraulic system, simple operation,Nai meihengHydraulic fixed lifting platform, large load-bearing capacity, and rear hinge support.

The lifting platform is a multifunctional heavy loading and unloading mechanical equipment, which can be divided into fixed and mobile, guide rail and curved arm types. Fixed types include scissor elevators, chain elevators, loading and unloading platforms, and attached electric construction platforms.

The cylinder head oil seal is too tight or the rod is bent, which can also cause noise during movement due to other forces. At this point, the oil seal or straightening rod must be replaced in a timely manner.