Alfin Anden RyanSmall electric loading elevatorWhere is the advantage in

announcer:hp935HP175192871 release time:2023-12-19 12:53:29

The pump body adopts an integrated pump station all equipped with imported high-quality pump stations, which can also be selected according to customer requirements to meet customer ideal requirements.

Setting requirements: Each landing entrance should be equipped with a landing door, which should cover the opening with its full width, and should not open towards the lifting passage.

Alfin Anden Ryan.We have all purchased the aluminum alloy electric elevator equipment, which is compact and easy to carry. Many garden style hotels, hospitals, airports, and large parking lots also wear this equipment,Alfin Anden RyanSmall electric elevator platform,

Monthly maintenance and inspection of hydraulic lifting platform rollers, intermediate shafts and bearings, boom hinge shafts and bearings for wear. Add some oil to each part to extend the service life of the lifting platform bearings. The quality and level of hydraulic oil. The lifting platform should be raised throughout the entire process, and at this position, the hydraulic ground should be 40-50 millimeters higher than the bottom of the box. If the hydraulic oil becomes dark, sticky, or has foreign objects such as gravel, it should be replaced in a timely manner (32 # hydraulic oil). Annual maintenance and inspection of all hydraulic pipelines and joints of the lifting platform. The pipeline must not be damaged, and the joints must not be loose. All joints must be tightened. Remove and disassemble the lowering valve of the lifting platform, tighten the joint then install it and reinstall it. Drain and discard the hydraulic oil, remove the oil filter, clean it with compressed air, and then return it to the oil tank and connect the pipeline.

.From the perspective of the safety performance of the machinery itself, those that have undergone national safety certification will not have significant safety issues. The main problem is that after using the electric elevator for a period of time, mechanical components may fall off or be damaged due to various factors. This problem depends on regular inspection and maintenance of the machinery

Acceptance: Concrete strength grade C30, strength testing report.

Setting requirements: The anti loosening and anti loosening parts between the connecting parts should comply with the provisions of the user manual and should not be replaced by other objects. For connecting bolts with pre tightening requirements, a torque wrench or special tool should be used to accurately tighten the bolts to the specified torque value according to the specified tightening sequence. When installing standard section connecting bolts, it is advisable to place the screw at the bottom and the nut at the top.


Alfin Anden RyanSmall electric loading elevatorWhere is the advantage in



Setting requirements: For construction electric elevators that operate in multiple shifts, the handover system should be implemented, which should be able to cut off the power supply before the suspension cage and other mechanical stop devices (such as buffers), so that the suspension cage can stop

Safety performance: Electric elevators not only have the safety device of traditional traction elevators, but also have an overflow valve to prevent excessive system pressure during upward movement

reform.Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

The full height landing door should meet the following requirements: the net height of the landing door opening should not be less than 0m. In special circumstances, when the net height of the building entrance is less than 0m, it is allowed to lower the height of the lower door opening, but in any case, the net height of the lower door opening is not less than 8m. (Article 1 of GB26557-2011)

Especially suitable for steel structured factories, suitable for both indoor and outdoor installation.


Alfin Anden RyanSmall electric loading elevatorWhere is the advantage in



The scaffolding of the parking platform should be laid tightly and firmly.

Quality management.Double layer steel mesh: The diameter of the steel bars is 12mm, with a spacing of 200mm.

Before installing the construction electric elevator, the foundation should be inspected and approved before installation.

The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

Alfin Anden Ryan.In addition to ground protective fences, low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings,Alfin Anden RyanLarge electric elevator, a half height middle crossbar, and a toe board at least 150mm above the ground.

The scaffolding of the parking platform should be laid tightly and firmly.

Setting requirements: Each landing entrance should be equipped with a landing door which should cover the opening with its full width, and should not open towards the lifting passage.