Levalova pereSecond floor cargo elevatorPrice index operation analysis

announcer:hp779HP136589660 release time:2023-11-10 13:55:24

To ensure excellent power supply at the installation site,Levalova pereGuide rail chain elevator, install a separate distribution box. When using the distribution box, the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.

Unscrew the screws on the dustproof hole on the outer side of the elevator flange, adjust the PCS system ring to align its side hole with the dustproof hole, and tighten with the hexagon socket. After that, remove the motor shaft key.

Levalova pere.Precautions for daily maintenance of hydraulic lift cargo elevator Check all hydraulic pipes and joints of the hydraulic lift cargo elevator. The pipes must not be damaged and the joints must not be loose. All joints must be tightened.

Incorrect connection of the elevator motor When a coil, or one phase winding group is connected inversely, it must be ensured that the concentricity of the elevator output shaft and the motor input shaft is consistent, and that the outer flanges of the two are parallel. Inconsistent centering can cause the motor shaft to break or the elevator gear to wear.

Usage: Scissor fork type fixed lifting platforms are mostly used for goods transportation between height differences in production lines, loading and unloading materials, adjusting the working height during workpiece assembly, feeding materials to loading machines at high altitudes, lifting components during assembly of large equipment, matching storage and loading sites with forklift trucks and other transportation vehicles for rapid loading and unloading of goods, vehicle lifting, fixed three-dimensional parking, and other places.

Walking: assisted self-propelled, two wheel traction, self driving, and car modification.


Levalova pereSecond floor cargo elevatorPrice index operation analysis



Large logistics warehousing equipment service company with guaranteed prices and guaranteed services, directly operated by the manufacturer. Because fixed elevators are mechanical equipment, the quality and performance of the product are good. Do not accept products from some manufacturers that do not meet the quality standards, in order to avoid some safety hazards in use.

If the hydraulic valve is damaged its effectiveness should be maintained. If it is damaged, it can be replaced in a timely manner.

Incorrect connection of the elevator motor When a coil, coil group or one phase winding group is connected inversely, it can cause a serious imbalance in the three-phase current and cause the winding to overheat.

Create brilliance.Incorrect connection of the elevator motor When a coil, coil group, or one phase winding group is connected inversely, it can cause a serious imbalance in the three-phase current and cause the winding to overheat.

Corrosion prevention measures for the body of aerial work vehicles Attention to small scratches The paint surface of aerial work vehicles often corrodes. In addition to common collisions, and small rocks on the drive tire, there can also be a paint peeling point that can cause a small rust over time. Because most of these scars are small and easy to ignore. Therefore, regularly inspect the engine compartment lid and surrounding areas, and once found, go to a professional beauty shop for processing in a timely manner.

Goods should be stacked well on the platform, and should not be tilted. When the goods elevator is lifting or lowering beyond the scope of the platform, no one should stand around to watch.


Levalova pereSecond floor cargo elevatorPrice index operation analysis



Is the water cooling and air cooling of the hydraulic station the same?

Quality documents.Purpose The hydraulic lift is widely used in various industrial enterprises and production lines such as automobile, container, mold manufacturing, wood processing, chemical filling, etc., to meet the lifting requirements of different operation heights, and can be equipped with various table forms (such as ball,Levalova pereCapable of lifting cargo elevators, steering turntable, telescoping), and with various ways (separate, linkage, explosion-proof), it has the characteristics of stable and accurate lifting,Levalova pereSimple lifting cargo elevator for factory building, frequent starting, and large load capacity, Effectively solve various lifting and lowering operation difficulties in industrial enterprises, making production operations free. Professional elevator factory has advanced technology, strict testing, more affordable prices, and more preferential treatment. Welcome to consult

Small pneumatic or electric derusting, which uses the principle of friction generated by air compression or electromagnetic effects to polish and remove rust on the surface of a spiral elevator, can be used for precision instrument push rods or for enterprises that require micro operation of spiral elevators.

Guide rail elevator (also known as cargo elevator) is a non scissor fork type hydraulic lifting platform, mainly used in industrial buildings, restaurants, restaurants, warehouses, docks, workshops, and other places where vertical cargo handling is required between two or more floors. The low height is particularly suitable for sites that are not suitable for digging pits on site. What issues should we pay attention to in these places where elevators are used?

Levalova pere.The motor winding is short-circuited. When a short circuit fault occurs in the motor winding, the short circuit current is much larger than the normal working current, which increases the copper loss of the winding, causing the winding to overheat or even burn out.

Before connecting the motor to the elevator, the elevator manufacturer should first make the motor shaft keyway perpendicular to the tightening bolt. To ensure uniform stress, first screw on the mounting bolts at any diagonal position, but do not tighten them. Then screw on the other two mounting bolts at diagonal positions, and then tighten the four mounting bolts one by one. After that, tighten the tightening bolts. All tightening bolts shall be fixed with a torque wrench according to the indicated fixed torque data and the use of elevators and lifting platforms shall be checked

Safety performance: The lifting structure is made of high-strength manganese steel rectangular tubes, with a scissors type mechanical mechanism, easy to maintain, strong stability, and high bearing capacity. The lifting height is about 10 meters, and the load capacity is about 10 tons.