Corpus ChristiLifting table hydraulic pressureHow to improve the durability of life

announcer:hp530HP141750488 release time:2024-05-05 14:22:45

Reason: The lowering valve is not tightly closed. Cleaning method: Check if the lowering valve is powered on. If there is no power supply, clear the malfunction of the lowering valve itself or replace the lowering valve. It is necessary to keep the valve of the lowering valve clean and flexible.

When the hydraulic system malfunctions, the hydraulic elevator may experience problems with the hydraulic pump, motor, valve, and hydraulic installation after repairing the hydraulic system, which can easily cause vibration and generate significant noise.

Corpus Christi.The safety belt should be inspected before use and a static load test should be conducted regularly (every 6 months). The load for the boarding bridge test is 225 kilograms and the test time is 5 minutes. After the test, check for deformation, cracks, etc., and keep test records. Unqualified seat belts should be promptly dealt with.

When using hydraulic elevators, frequent inspections and maintenance should be carried out, which not only extends the service life of the hydraulic elevator, but also enables it to exert greater power during operation. Of course, hydraulic elevators also have their own regular repair times and protection methods: regular protection (carried out per shift).

. There is air in front of the pilot valve of the elevator overflow valve noise overflow valve. The damping hole on the main valve core of the overflow valve is blocked by oil dirt, and the pilot valve and valve seat are matched without spring deformation or incorrect installation. The remote control port has excessive oil flow, low or high hydraulic oil viscosity,Corpus ChristiGuide rail hydraulic lifting platform, and resonance occurs with components in the circuit. Troubleshooting: Strengthen sealing, repeatedly adjust the pressure, exhaust and clean the valve body several times Make the damping hole unobstructed,Corpus ChristiMobile elevator hydraulic lifting platform, repair or replace the spring, reduce the flow of the remote control port, and other components. The pressure setting of other components should not be similar to the pressure setting of the relief valve. 5. The noise of the elevator pipeline is usually caused by excessive dead bends or loose fixed sleeves in the hydraulic pipeline.

The manufacturer of hydraulic cargo elevators will tell you about the knowledge of specialized lifting platforms for unloading.

The noise and oil level of the elevator oil cylinder are too low. From the air at the connection of the oil filter or joint to the oil, the coupling inside the oil cylinder is loose. The internal fault of the oil cylinder is that the installation of the oil cylinder motor is not concentric. From the motor, the air and oil at the moving shaft are blocked. The oil return pipe of the oil filter is loose, and the air or oil pipe is on the oil surface, filter the oil, lock the return oil pipeline, and extend the return oil pipeline below the oil level. If there is air mixed in the oil or the air in the hydraulic cylinder is not completely discharged, it will cause cavitation under high pressure and cause significant noise. At this point, it is necessary to exhaust the air in a timely manner.


Corpus ChristiLifting table hydraulic pressureHow to improve the durability of life



Therefore, in the hydraulic pipeline assembly line, it is necessary to avoid dead bends as much as possible and check the tightness of the sleeve in a timely manner.

When repairing the hydraulic system, only clean plastic plugs can be used to seal the end of the pipeline.

Car mounted lifting platform: The car mounted lifting platform is designed to improve the mobility of the lifting platform by fixing it to a transport vehicle or truck. It receives power from the car engine and achieves the lifting function of the car mounted lifting platform. To adapt to high-altitude operations inside and outside the factory area.

reform.Hydraulic lift cargo elevators belong to high-altitude work equipment. Small shaking of the scissor type structure is normal,Corpus ChristiLifting platform hydraulic pressure, but excessive deviation is a symptom. It is necessary to find the cause and make correct judgments in a timely manner. Generally speaking, operations above 8 meters are generally allowed. Due to its own weight, devices above this height begin to vibrate in different ranges. The vibration range depends on factors such as weight, lifting height, and intensity of high-altitude operations.

The lifting platform is a multifunctional heavy loading and unloading mechanical equipment, which can be divided into fixed and mobile, guide rail and curved arm types. Fixed types include scissor elevators, chain elevators, loading and unloading platforms, and attached electric construction platforms.

Oil leakage is a common malfunction. Due to loose joints or damaged sealing rings oil leakage may occur. Therefore, this fault can be solved by tightening the oil leakage joint or replacing the damaged sealing ring.


Corpus ChristiLifting table hydraulic pressureHow to improve the durability of life



Regularly check all wires and cables for damage. It is necessary to wrap and replace the damaged parts in a timely manner.

The cost is reasonable.Oil leakage is a common malfunction. Due to loose joints or damaged sealing rings, oil leakage may occur. Therefore, this fault can be solved by tightening the oil leakage joint or replacing the damaged sealing ring.

The hydraulic pump also has an impact on the flow rate of hydraulic oil. If the hydraulic pump is used for a long time, it is also prone to problems. When the speed of the hydraulic lifting table slows down, it is necessary to check whether the oil supply of the hydraulic pump is firm and firm.

When encountering signs of overheating in the electric motor, it is necessary to park the car in a timely manner, clean the problem, and continue running. The motor bearings should be smooth and outstanding.

Corpus Christi.The elevator is evenly distributed at any position on the guide rail at 150% of the maximum load capacity, and should be stable at the maximum lifting height.

The lifting platform is placed on a horizontal support surface and the concentrated load of MAX load capacity is placed at any position 300mm away from the periphery of the workbench. After lifting 100 times, each load-bearing component must not have deformation or cracks.

Considering the oil level in the oil tank, when all hydraulic cylinders in the system are extended, the oil level in the oil tank should not be lower than the Z-low oil level, the oil level should not be higher than the Z-high oil level. In fact, most manufacturers have noticed the above issues. The reason for the introduction is that most users can learn more about the equipment itself when using elevators, in order to facilitate equipment maintenance. Hydraulic cargo elevator manufacturers sincerely hope that you choose a legitimate manufacturer when purchasing elevators