BotanzaIndoor electric elevatorDesign and selection

announcer:hp935HP175192871 release time:2024-03-31 09:25:15

Construction electric elevators outside the lightning protection range

Setting requirements: When the distance between the outer edge of the construction electric elevator and the external overhead power line cannot meet the requirements of a small safety distance, the protective measures taken should comply with the specification requirements.

Botanza.Pole

When the landing door is closed, the full width of the lifting passage opening should be covered.

.Mechanical devices controlled by cage movement should not be used to open or close the landing door.

The counterweight guide rail should meet the specification requirements.

Setting requirements: The wall bracket should use the manufacturer's matching standard products.


BotanzaIndoor electric elevatorDesign and selection



A complete lifting platform accessory can be selected and customized according to different places, venues, and environmental usage conditions. Meet the needs of different users. So why lifting platforms can be used and installed in so many industries and places is because they can achieve multi-purpose, demonstrate multifunctional, meet various different needs, and win market demand. In modern industrial transportation processes, lifting platforms have begun to play an increasingly important role,BotanzaSmall electric elevator, whether in airports, docks warehouses, floors, workshops and other places that require rapid loading and unloading of goods, they have played a very practical value, It has also brought great contributions to the entire industry and even the entire economic development. However,BotanzaElectric four-wheel elevator, long-term operation and use of these devices inevitably lead to wear and consumption, and regular maintenance and upkeep are essential. Otherwise, the gains and losses will outweigh the losses.

Setting requirements: Construction electric elevators should be equipped with up travel (limit) switches.

The use of standard section connecting bolts should comply with the user manual and specification requirements.

Variable cost.The setting of the cable guide frame should comply with the user manual and regulatory requirements.

Emergency manual valve: In case of power failure and at that time, it can cause the car to descend to the nearest floor position and open the door

Setting requirements: The landing door should be standardized and tooled.


BotanzaIndoor electric elevatorDesign and selection



Low level doors should be equipped with interlocking devices that can verify their closed and locked positions. The action of this interlocking device should be at the entrance of the cage. Simple use should not interfere with the operation of the interlocking device. The attached wall bracket should use matching standard products. When the wall bracket cannot meet the requirements of the construction site, it should be designed separately. The design of the wall bracket should meet the requirements of component stiffness, strength,BotanzaElectric clothes drying elevator, stability, etc., and the production should meet the design requirements.

resources.Especially suitable for steel structured factories, suitable for both indoor and outdoor installation.

The body in the lateral adjustment device of the driving plate should ensure a compressed state, so that the gear has a certain radial constraint, and ensure that the gear and rack always mesh well throughout the entire operation.

News Abstract: The development of the lifting platform industry will continue to grow in recent years! With the continuous development of electric lifting machinery for high-altitude operations in recent years, the products of electric lifting platform vehicles have been continuously improved, making the further development of lifting platform vehicles possible.

Botanza.The setting of the cable guide frame should comply with the user manual and regulatory requirements.

There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.

Mechanical devices controlled by cage movement should not be used to open or close the landing door.