West-RaleighInstallation of industrial cold storageHow is the production status

announcer:hp632HP195506591 release time:2022-01-14 11:41:23

The construction structure of structural cold storage can be brick concrete structure or steel structure, most cold storages are constructed with single-layer steel structure, unloading platform, refrigeration system, system, pipeline system, etc. according to the actual needs of cold storage circulation.

The assembled cold storage body often adopts double-sided color steel plate of polyurethane thermal insulation material, which has excellent thermal insulation performance, more important is the choice of refrigeration system. For example, at present, the refrigeration system of fluorine refrigerant is still the mainstream, but when selecting the type and power of cooling equipment, it is necessary to calculate the data for the installation of cold storage, and then make a high-quality choice.

West-Raleigh.The electric cabinet shall be in strict accordance with the requirements of the drawing, and the power shall be connected for no-load test.

During operation, the water temperature will still drop, and the humidification amount will be reduced by 70% at 5 ℃.

.Preparation, prepare the project planning of cold storage, and prepare the construction site and construction materials. All kinds of materials for cold storage construction are customized according to the needs of customers. Sort out the construction site that meets the requirements transport all installation materials to the construction site, check the material quality and model, and start the installation of cold storage after confirmation.

On the basis of cold storage and preservation, the quick-frozen warehouse increases the regulation of gas composition, inhibits the respiration of fruits and vegetables, delays their metabolic process, better maintains the freshness and commercial quality of fruits and vegetables, and prolongs the storage period and shelf life of fruits and vegetables. Generally, controlled atmosphere storage of fruits can prolong the storage period by 2 & mdash; Three times or more. OK, what is the standard of quick freezing warehouse?

Indirect cooling is that the air in the warehouse is pumped into the air cooling device by the blower. The air is absorbed by the evaporation pipe circling in the cooling device, and then sent to the warehouse for cooling. The advantages of air cooling are rapid cooling, and can bring harmful gases such as carbon oxide out of the warehouse during storage.


West-RaleighInstallation of industrial cold storageHow is the production status



A large number of personnel are not allowed to select goods in the warehouse. Close the warehouse door in time. When the warehouse door is opened, pay attention to whether the air curtain is opened or the door curtain is placed properly. Turn off the lights when leaving the warehouse.

If spraying is used, the tightness of warehouse doors and windows shall be considered.

The assembled cold storage body often adopts double-sided color steel plate of polyurethane thermal insulation material, which has excellent thermal insulation performance, storage and circulation effect and reduces operation energy consumption. Of course, more important is the choice of refrigeration system. For example, at present the refrigeration system of fluorine refrigerant is still the mainstream, but when selecting the type and power of cooling equipment, it is necessary to calculate the data for the installation of cold storage, and then make a high-quality choice.

safety requirements .The foaming technology of polyurethane with strong stability makes it have superior bonding performance. The firm combination of polyurethane rigid foam and carrier layer is the basic premise to ensure the stability of external insulation layer. That is, under the unfavorable local temperature and humidity conditions, it can bear various internal and external combined loads such as wind force, self weight and normal collision, and the insulation layer still does not separate and fall off from the carrier layer and remains stable in the state.

Connect the refrigeration system. Wires and copper pipes shall be used to connect the refrigeration unit, electric control system and other components of the cold storage. The connecting pipes shall be closely connected, and corresponding thermal insulation and protection measures shall be taken.

Disadvantages of single-layer cold storage: large; The surface area of the external enclosure structure of the cold storage is large, so the amount of thermal insulation materials is large, and the dry consumption of cold food is also large; For the low-temperature warehouse, the floor anti freezing treatment requires a large amount of work. When the cold storage is built at the water level, it is impossible to deal with it, which is easy to cause horizontal freezing and swelling.


West-RaleighInstallation of industrial cold storageHow is the production status



The physical properties of polyurethane insulation board are relatively good, which can meet different needs. The polyurethane insulation board is also strict in the selection of materials. It is a special product manufacturing enterprise integrating R & D, and service. It has long been specialized in cold storage installation, cold storage installation, cold storage construction fruit preservation cold storage and medical cold storage. It improves the overall performance of the polyurethane insulation board and enables the polyurethane insulation board to work for a long time, Polyurethane insulation board has also become one of the main exterior wall materials.

High quality brand.The evaporator surface is too thick or too much dust, and the heat transfer effect decreases: another important reason is that the heat transfer efficiency of evaporator is low, which is mainly caused by excessive frost or excessive dust on the evaporator surface.

Pressure leak test: the pressure leak test of the fresh-keeping warehouse system is the same as that of the sewage blowing working sample, which is required to be carried out by air compressor. If ammonia compressor is used, a special one shall be designated and the exhaust temperature shall be strictly controlled. When high pressure is applied, the method of segmenting and reducing the pressure difference shall be adopted.

Acid disinfectant can be used for mold removal and disinfection of quick-frozen warehouse.

West-Raleigh.Requirements for the cold storage time of the device: the cold storage of the refrigeration system using ammonia as refrigerant shall be supported in the place with low population density around.

The construction of small cold storage is widely used in life, such as food industry, manufacturing industry, etc. since cold storage is so widely used, do you know cold storage? Especially the construction process and steps of cold storage. Understanding the construction process and steps of cold storage is helpful for all links of cold storage maintenance.

The water tank is designed to be separated from the machine body and is double-layer. It will not drip due to condensation caused by internal and external temperature difference. It can be interlocked with the refrigeration system, that is, it will not be humidified during refrigeration to prevent serious frosting of the fan.