PuntarenasCold storage compressor installationWhat are the key points of spot trading

announcer:hp632HP195506591 release time:2022-03-17 11:24:36

but it has a great impact on the cost of quick freezing warehouse and later use cost. The electricity bill is often an important expenditure item in the later stage. The design scheme of the show can greatly reduce the power consumption of the quick freezing warehouse. The selection of the back sunny side of the quick freezing warehouse, the selection of the thickness of the thermal insulation board should be appropriate, the tightness of the quick freezing warehouse door, and the temperature difference between the adjacent cold storage rooms should not be too large are all issues that we need to consider. There are also some tips, such as the use of air curtain machine on the quick freezing warehouse door. We remind users to use parallel units in quick freezing warehouse as far as possible and start them reasonably.

The use of large-scale cold storage is naturally very strict in installation and material selection. Therefore, in the face of the above possible situations, we can strictly screen the insulation board materials of cold storage, which can effectively alleviate or solve the above problems. However, at present, there are many fields using cold storage insulation board, so the details of the use environment should be considered for the wood making of many such products in the market.

Puntarenas.Precautions for fruit delivery: it is the same as warehousing. It should be gradually adapted during delivery to avoid condensation on the fruit surface, dark color, and the relative humidity should be 75% ~ 80%, When the temperature rises to 4 ~ 5 ℃ different from the external temperature, it can be delivered from the warehouse.

During the production of cold storage, the cold storage will produce fixed length, width and thickness according to the needs of various cold storage projects. Generally, 10cm thick cold storage plates are selected for high and medium temperature cold storage. The requirements for cold storage engineering plates of low-temperature storage and quick-frozen storage will be higher. Professional cold storage installation, installation, construction, fruit fresh-keeping cold storage and medical cold storage ensure the quality, Guarantee service. Guarantee quality. Your satisfaction is our pursuit! Welcome to inquire. In this case, use 12cm or 15cm thick library board. When you budget the cold storage project, you can make a reservation according to the specific conditions of your cold storage temperature. If you don't make a reservation for the cold storage plate, you should pay attention to the density of the cold storage plate and the thickness of the steel plate when purchasing the cold storage plate. According to the regulations the cold storage shall be distributed

.The type of cold storage to be built in the type of cold storage should be determined according to the type of circulating goods. For example,PuntarenasInstallation price of cold storage, the cold storage that only circulates vegetables can only build a fresh-keeping cold storage, while the cold storage with refrigeration + freezing will be built if there are many types of circulating goods and great difference in storage temperature. As for the size of the cold storage, it should be determined according to the type, quantity, frequency, cycle, whether to use shelf stacking and so on. For example, for fruits and vegetables packed in cartons, the storage capacity of 280-330kg per cubic meter can be referred to, and the size of cold storage construction can be estimated in combination with the storage capacity rate of about 0.5-0.6.

The factors affecting the installation cost of cold storage are as follows: cold storage construction: the site selection shall comply with laws and regulations and meet the relevant requirements for food hygiene and. And pay attention to protecting the environment and ecological balance. In addition, it shall be conducive to production, construction and dry ceremony.

1 - precautions for floor installation of cold storage: the floor shall be installed flat, the uneven part shall be leveled with materials, and the locking hook between the plates shall be locked to ensure that the warehouse surface is flat without hollow feeling. (note that if this drainage system is installed outdoors in the north, the required temperature can be reached in 10 minutes, but now it takes 30 minutes. In this way, the refrigeration is obviously slow and the effect is poor,PuntarenasInstall cold storage, which will directly affect the use cost.

The three-dimensional automatic cold storage adopts a computer, which can complete the loading, unloading and stacking in the storage, the control of storage temperature and the operation of refrigeration equipment.

Statistics.When installing polyurethane insulation board ensure that its surface is smooth and flat without scratch and warpage.

The floor of the cold storage shall be kept as close as possible during use

Wall and floor fixtures shall start at corners. According to the plate layout drawing, transport the two plates at the corner of the required device to the device location. According to the plate beam height and the model of the angle iron for fixing the mushroom head nylon bolt, drill a hole at the corresponding elevation in the middle of the plate width. When drilling, the electric drill should be perpendicular to the plate surface. Put the mushroom head nylon bolt in the hole, tighten the angle iron, and tighten it horizontally so as to make the nylon bolt on the surface of the warehouse plate slightly concave. When setting up the wall panels, foam data and other soft data should be laid on the floor slots along with the floor of the storehouse, so as to avoid damaging the storehouse. After the two corner panels are neutrally removed from the floor, the plane position of the wallboard and the verticality of the storehouse should be adjusted in time according to the location of the laying line, and check whether the top elevation of the wallboard can be correct. After the position of the wallboard is correct weld the angle iron on the plate beam and fix the inner and outer corners. When welding the angle iron parts, the angle iron parts of the warehouse plate shall be covered with a shield to avoid the high temperature of the welding ground baking the warehouse plate and welding slag on the warehouse plate during electric arc welding.


PuntarenasCold storage compressor installationWhat are the key points of spot trading



Connect the refrigeration system. Wires and copper pipes shall be used to connect the refrigeration unit,PuntarenasHow much is the installation of food cold storage, electric control system and other components of the cold storage. The connecting pipes shall be closely connected, and corresponding thermal insulation and protection measures shall be taken.

Finance Department.The water tank is designed to be separated from the machine body and is double-layer. It will not drip due to condensation caused by internal and external temperature difference. It can be interlocked with the refrigeration system, that is, it will not be humidified during refrigeration to prevent serious frosting of the fan.

Check whether the compressor phase current is stable.

However, so reasonable maintenance is particularly important.

Puntarenas.As a coolant, make it evaporate under low pressure and mechanical conditions to absorb the heat in the storage, so as to achieve the purpose of cooling.

Core tip: in the cold storage project, only with sufficient cold storage installation skills can we ensure that the cold storage is more energy-saving and power-saving after installation, and is not prone to failure, convenient use and management and long service life.

The average service life of rigid polyurethane insulation structure with stable quality, long service life and high comprehensive cost performance can reach more than 30 years under normal use and maintenance conditions. Under the normal service conditions during the service life of the structure, it will not be affected by drying, or electrochemical corrosion, as well as the growth of insects, fungi or algae or rodents.