Santa-AnaProduction of medical cold storagePrecautions should be kept in mind when using

announcer:hp632HP195506591 release time:2022-01-13 18:11:22

Whether the parameters of refrigeration equipment are consistent. When the cold storage leaves the factory, the temperature and temperature difference parameters of the cold storage shall be customized according to the user's requirements. After understanding the technical parameters of the cold storage, set the parameters on the refrigerator. During use, the air humidity is high and the defrosting interval is long. The common cold storage boards of cold storage include 100mm, 120mm, 150mm, 175mm and 200mm polyurethane thermal insulation boards, color steel tiles, stainless steel plates, salt thick steel plates, embossed aluminum plates, polyurethane spraying, etc. on both sides or single and double sides, more general color steel tiles are produced and processed into hidden grooves, which have light weight, high compressive strength, good fire resistance, corrosion resistance and aging resistance, The cold storage board is simple and convenient to assemble, and it is also easy to deform and damage the appearance.

When installing the polyurethane insulation board, the adhesion between the panel of the polyurethane insulation board and the thermal insulation material is short and often high.

Santa-Ana.Protective fence shall be set around the door of the controlled atmosphere storage with eye-catching signs.

First, use a hammer to pad the wood on the polyurethane warehouse board between the two warehouse boards, so as to make the boards closely close to each other. Two sets of connecting pieces shall be wedged between the wall panel and the wall panel, outer and lower sides of the gap between the wall panel and the wall panel respectively. The lower connecting piece shall be as close as possible to the lower side, so that the post cast concrete can cover the connecting piece. After the gap between the plate and the plate ground is wedged with a connector, it shall be about 3mm wide. If it does not meet the requirements, remove the plate,Santa-AnaCold storage manufacturer, trim the plate edge, and then reinstall it to make the plate joint meet the requirements. When fixing the adapter, pay attention to fix the two parts of the adapter on the edges of the convex and concave library plates respectively, and fix them with rivets. The spacing of the adapter should be able to tension the two library plates. When wedging the wedge iron, the hammer shall be perpendicular to the wedge iron to prevent damaging the warehouse plate. The ground wedge iron at the upper and lower parts shall be wedged at the same time, and the wedge iron shall be fixed with rivets.

.Initial operation unit of cold storage equipment: regularly observe the oil level and oil return of the compressor and the cleanliness of the oil. If the oil is dirty or the oil level drops, it shall be solved in time to avoid adverse effects.

Drainage measures shall be provided for the villa room and overhead layer of the road surface of the cold storage engineering building.

When opening and drilling is required for the top warehouse plate or wall plate, the internal and external setting out and positioning shall be carried out according to the drawing design requirements, and the opening and drilling shall be carried out after review; The inlet hole, liquid inlet hole, return hole, water supply hole and drainage hole shall be opened with a hole opener. Construction treatment shall be carried out in time after opening and drilling, and the orifice shall be closed with foaming material or sealant to prevent air leakage and cold running; The door, vent and delivery port shall be decorated with wrapped edges and fixed with pull rivets, with a spacing of 300mm and 150mm outside.


Santa-AnaProduction of medical cold storagePrecautions should be kept in mind when using



2. Maintenance of food cold storage. In a position convenient for operation outside the door of the refrigerator room a main switch for cutting off the power supply of the refrigeration compressor shall be set. This switch shall be able to stop the operation of the refrigeration compressor, and relevant signs shall be set. If the mechanical panel is set in the main room, a button switch shall be added next to each refrigeration compressor.

Expensive, high machining precision of body parts; High noise during compressor operation; Screw compressor can only be used in medium and low pressure range not in high-pressure occasions; Due to large fuel injection and complex oil treatment system, there are many auxiliary equipment of the unit.

The new cold storage material is made of rigid polyurethane or polystyrene foam insulation sandwich panel, which is made by high pressure foaming process and can be made into various lengths and specifications to meet the different requirements of the users.

management.The construction of cold storage in site selection bears the circulation of low-temperature goods. Therefore the transportation convenience of cold storage construction site should be given priority in site selection, such as proximity to roads railways, etc. At the same time, and the construction of the cold storage should have good drainage and ventilation conditions.

During production in the production workshop, the unit weight of Pu warehouse board shall not be less than the unit weight required by the project, electric control system and other components of the cold storage. The connecting pipes shall be closely connected,Santa-AnaFruit and vegetable fresh-keeping cold storage, and corresponding thermal insulation and protection measures shall be taken.


Santa-AnaProduction of medical cold storagePrecautions should be kept in mind when using



The new cold storage material is made of rigid polyurethane or polystyrene foam insulation sandwich panel, which is made by high pressure foaming process and can be made into various lengths and specifications to meet the different requirements of the users.

Installation materials.During operation, the water temperature will still drop, and the humidification amount will be reduced by 70% at 5 ℃.

The cold storage construction in the site selection undertakes the circulation of low-temperature goods. Therefore, when selecting the site, priority should be given to the transportation convenience of the cold storage construction site, such as close to roads and railways. At the same time, the location of the cold storage should avoid large pollution sources and direct sunlight, and the construction of the cold storage should have good drainage and ventilation conditions.

Whether the water pump works normally and whether the moldy switch is effective. In case of abnormality, timely handle the overhaul and maintenance of the refrigeration compressor in the cold storage: generally, the refrigeration oil and drying filter shall be replaced 30 times after the operation of the cold storage equipment. Replacement after half a year. Depending on the circumstances.

Santa-Ana.Generally, in the actual operation of the refrigeration system, because the temperature conditions are constantly changing, only by relying on the careful operation of the cold storage management personnel and accurately adjusting the operation of the refrigeration equipment of the cold storage, can the refrigeration system always be in the ideal working state and achieve the effect of energy saving.

The bubble density is 38 kg to 40 kg / m3 per cubic meter, the main raw materials of special cold storage board for cold storage project are polyphenylene, polyethylene and polyphenylene grease. The density of thermal insulation material foamed by polyphenylene is thin, and the thermal insulation coefficient is not very high; After a certain ratio of polyethylene, it can foam cold storage insulation materials with appropriate density and good thermal insulation effect, and has high load-bearing capacity; Polyphenylene resin has strong water absorption, but poor heat insulation. Therefore, the polyurethane sandwich board with very good performance belongs to the polyurethane sandwich board. Although it is slightly higher, the polyurethane board has very good thermal insulation performance and does not absorb moisture.

Refrigeration system: refrigeration system is the core part of cold storage design. It is the key to determine the economy, environmental protection and performance of cold storage.