BytcaCold storage engineering design and installation manufacturerIt's hard to say how smooth the rebound is when the peak season comes

announcer:hp632HP195506591 release time:2021-11-03 14:19:01

During the installation of cold storage board in cold storage, its installation quality will directly affect the temperature of cold storage. As an important structure used in the cold storage, the cold storage board should pay attention to the details of its installation, find out the problems that are easy to be ignored, and avoid the wrong installation, which will affect the use of the cold storage or the whole installation process, so as to waste resources and increase the cost.

The service life of polyurethane cold storage insulation material foam is: besides the basic performance of the initial stage of polyurethane foam, the deterioration of foam performance is also a very important index. When the white material is prepared, the surface of some polyester materials can make the foam have better toughness and impact resistance, but it will become brittle after use for a long time in the cold storage, which is slightly brittle at the initial stage the poor hydrolysis resistance of some polyester foam will also affect the service life of the foam. It adopts polyether structure, but generally disappears after a few days and then maintains the stable performance of cold storage insulation materials for a long time.

Bytca.When adjusting the station, each outlet pipe shall be sawn into a 45 degree inclined mouth to the bottom, and the inlet pipe shall be 4 points of the pipe diameter of the adjusting station.

Cold storage has good water tightness. Polyurethane rigid foam has low water absorption, good permeability to water vapor, foam holes, disconnected and closed porosity of more than 95%. It is a dense microporous foam material, which is more dense than air surface, and is not easy to permeate. It belongs to hydrophobic materials.

.Cold storage design segmentation: several different partitions shall be reasonably planned and divided according to purpose and temperature. For example: processing room, sorting room, quick freezing room, refrigeration room, channel, unloading platform, etc.

Refrigeration system: refrigeration system is the core part of cold storage design. It is the key to determine the economy, environmental protection and performance of cold storage.

It is equipped with temperature compensation to automatically adjust the water temperature. The water temperature of ultrasonic atomization is 15-20 degrees. If our humidifier is connected with the warehouse there is no temperature compensation, even if


BytcaCold storage engineering design and installation manufacturerIt



The insulation board of the cold storage adopts polyurethane double-sided color steel plate. The main effect of this cold storage insulation board is good sealing performance insulation effect and moisture-proof effect, so as to ensure the refrigeration effect of the cold storage. The electric cold storage door is adopted for the cold storage door, and the cold storage management personnel can timely and effectively open and close the door when entering and leaving, so as to avoid the loss of refrigeration capacity of the cold storage.

In addition, water shortage or insufficient water in water-cooled machines will increase the exhaust temperature of the fresh-keeping warehouse. The condensation pressure is abnormal and the exhaust pressure of the fresh-keeping warehouse decreases.

We should implement regular maintenance and daily maintenance, professional cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage, large quantity, fire resistance - Waterproof - high temperature resistance, strong and durable, safe and reliable, and maintain the operation rate of the compressor.

Sales Department.The polyurethane insulation board used in the construction of cold storage shall be integral and continuous, and there shall be no joint in the middle. The junction of polyurethane insulation board, top plate and ground shall be made into fillet arc for transition, which can well meet the health needs.

On the basis of cold storage and preservation, the quick-frozen warehouse increases the regulation of gas composition, inhibits the respiration of fruits and vegetables, delays their metabolic process, better maintains the freshness and commercial quality of fruits and vegetables, and prolongs the storage period and shelf life of fruits and vegetables. Generally, controlled atmosphere storage of fruits can prolong the storage period by 2 & mdash; Three times or more. OK, what is the standard of quick freezing warehouse?

Cold storage is mainly used for


BytcaCold storage engineering design and installation manufacturerIt



The installation of top warehouse plate should be carried out alternately with the installation of wall plate, and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, the end steel sheet at the overlap with the wall plate shall be disconnected for 50mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, and the rivet spacing shall be 300mm; According to the design drawings, columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, column, support steel frame, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.

Installation conditions.The floor of the cold storage shall be kept as close as possible during use

Heat pump, hot water, refrigeration and other fields. Supporting downstream products include: household air conditioner, multi on-line, modular machine, small water ground source heat pump, etc. At present, a single scroll refrigeration unit can achieve 20 ~ 30HP.

Precautions for purchase and shipment when using the medical cold storage project, the speed must be strictly guaranteed during the purchase and shipment of products. If the temperature of the medical cold storage is about degrees, the opening time can not be too high, strictly within minutes.

Bytca.Here we focus on polyurethane. Polyurethane is an ideal cold storage material in the cold storage project. Superior bonding properties make the foam and metal panels form a solid whole so that no other adhesive materials are needed. When polyurethane is used as a cold storage project, rigid polyurethane foam is formed between the panels of the storehouse panel, and then solidified and pressed to form a multi shape storeboard, because the metal plate can roll out different waveforms, so that the overall rigidity is stronger and the bearing capacity is higher. Polyurethane filler board can meet the firmness and physical requirements of exterior wall and can be used in various cold storage projects. It is technically feasible and cost-effective. Yuanbao refrigeration believes that polyurethane is one of the new cold storage materials with great development prospects in the future. The thermal insulation materials of cold storage engineering should not only have good thermal insulation performance, but also be economical, applicable and environmental friendly. To ensure the smooth progress of our cold storage project, we should not only inquire about the raw materials of the cold storage, but also the types of cold storage. The common cold storage plates mainly include the following types, namely stainless steel plate, color zinc steel plate, salted steel plate, embossed aluminum plate and 0mm galvanized standard floor plate.

The temperature is too high, the condenser is blocked in the cold storage, the compressor is overloaded, there is a lack of refrigerant, the low pressure is too low, the air intake is too large, and the compressor is stuck.

Requirements for the cold storage time of the device: the cold storage of the refrigeration system using ammonia as refrigerant shall be supported in the place with low population density around.