KedzierzynKozlePreservation of fruits and vegetables in cold storageThe professional market is picking up and the price is going to fly

announcer:hp632HP195506591 release time:2021-11-02 15:01:49

Thermal insulation performance of thermal insulation materials for food cold storage the requirement of polyurethane thermal insulation materials for cold storage is thermal insulation performance, and the quality of thermal insulation performance cannot be observed before it is really put into use. It is too late to observe the difference between power consumption. In this large number of experimental tests, strict material selection is carried out in order to achieve this goal: using structural amine ether to reduce thermal conductivity and improve thermal insulation effect; Reduce the water content of various raw materials and formulas as much as possible to avoid deterioration of thermal insulation performance caused by water foaming; Polyether: the product of a large processed factory after strict postprocessing is compared with the polyether of small factory without postprocessing. The foam cell has high uniformity of foam pores and thin wall of foam holes, and its heat preservation performance is obviously better than that of ordinary foam with thick wall and big hole. The use of the tasteless amine catalyst can effectively adjust the balance between foaming and gel reaction, so that the interlayer skin of the sprayed coating is thinner, which is beneficial to the performance of the thermal insulation material of the cold storage. Ordinary polyester polyols are not used.

Cold storage has good water tightness. Polyurethane rigid foam has low water absorption, foam holes, disconnected and closed porosity of more than 95%. It is a dense microporous foam material which is more dense than air surface, and is not easy to permeate. It belongs to hydrophobic materials.

KedzierzynKozle.Evaporation temperature the sweating temperature of the refrigeration in the wafer machine needs to be lower than the air temperature in order to transfer heat from the engine room to the refrigerant. Usually, the temperature difference of room air conditioner is between 12C and 14C. If the temperature difference cannot be maintained due to adverse factors the operation energy consumption will increase.

Installation of unit electrical box: the unit electrical box shall be installed near the unit; Vertical installation. If the unit is installed on the top of the warehouse, the distance between the box bottom and the top of the warehouse must be & amp; amp; gt; 100 mm; The electrical box can be fixed on the building wall or on the angle steel frame.

.The temperature and humidity in the warehouse shall be kept uniform without movement; Try to finish the food in the warehouse at one time.

The spacing of pull rivets at inner and outer corners is 300mm and 200mm respectively; After the polystyrene library is installed, the wall panel joints shall be evenly sealed and decorated with silicone sealant.

During the production of cold storage, width and thickness according to the needs of various cold storage projects. Generally, 10cm thick cold storage plates are selected for high and medium temperature cold storage. The requirements for cold storage engineering plates of low-temperature storage and quick-frozen storage will be higher. Professional cold storage installation, installation, construction, fruit fresh-keeping cold storage and medical cold storage ensure the quality, Guarantee service. Guarantee quality. Your satisfaction is our pursuit! Welcome to inquire. In this case, use 12cm or 15cm thick library board. When you budget the cold storage project, you can make a reservation according to the specific conditions of your cold storage temperature. If you don't make a reservation for the cold storage plate, you should pay attention to the density of the cold storage plate and the thickness of the steel plate when purchasing the cold storage plate. According to the regulations, the cold storage shall be distributed


KedzierzynKozlePreservation of fruits and vegetables in cold storageThe professional market is picking up and the price is going to fly



Install the temporary lighting facilities in the warehouse, install and arrange the construction electrical equipment, and do a good job in rain proof moisture-proof, anti-collision, anti binding and other safety protection.

The wholesale electronic control system of fresh-keeping storehouse is the main component of the wholesale intelligent system of fresh-keeping storehouse. The intelligent electronic control has the functions of automatic cooling, heat preservation, stop, defrosting, delay and other related functions. The electronic control humanized mode saves the complicated work of manual operation. The wholesale seafood machine of fresh-keeping storehouse is used for seafood breeding and other temperature systems. The principle is similar to that of air conditioning. The main components are titanium barrel, fan, compressor, temperature controller, through valve and other components. Next, fresh-keeping warehouse wholesale is introduced in detail

The refrigeration of cold storage pays more and more attention to the needs of environmental protection and energy saving. Professional projects include: cold storage installation, installation of cold storage, cold storage construction, fruit fresh-keeping cold storage, medical cold storage and other related businesses. Merchants who hope to have this business please consider the wide scale of warehouse temperature control, the selection and placement of cooling equipment and the description of wind speed field, which are suitable for the cold storage needs of a variety of goods. Equipped with perfect storage temperature active detection, recording and active control equipment.

Service first.Compression refrigerator is commonly used, which is mainly composed of compressor, condenser, throttle valve and evaporation pipe. According to the way of evaporation pipe device it can be divided into direct cooling and indirect cooling. Direct cooling the evaporation pipe is installed in the refrigerated warehouse. When the liquid coolant passes through the evaporation pipe, it will directly absorb the heat in the warehouse and cool down.

With the development of the times, it is very important to select materials with good thermal insulation. Cold storage is a better material selection, refrigeration devices are becoming more and more common. All aspects of life are inseparable from its use. Families will also be equipped with some simple refrigeration devices. For refrigeration devices such as cold storage, it is very important to select materials with good thermal insulation. Cold storage is a better material selection, and manufacturers need it in the production process of cold storage


KedzierzynKozlePreservation of fruits and vegetables in cold storageThe professional market is picking up and the price is going to fly



Technical assurance measures for the installation of cold storage: during production in the production workshop, the production shall be carried out in strict accordance with the operation rules specified in ISO9002 quality operation, self inspection and inspection application shall be carried out to ensure that the factory pass rate is, and unqualified products are not allowed to leave the factory.

Inspection environment.Cold storage design steps: selection and preparation of cold storage location. According to the application characteristics, cold storage can be divided into sexual cold storage, retail cold storage and large-scale cold storage. When large-scale cold storage starts to build a planting area with more centralized hand supply, factors such as superior geographical location and contact with the market should also be taken into account. The cold storage should be located in a cool place without sunlight and frequent warm air. Small and medium-sized cold storage is better

Clean the condenser. The condenser is used as the heat dissipation and condensation of the compressor. Because it works in the outdoor environment, in the face of nature and for a long time, the condenser will be covered with a lot of dust and other foreign matters. These dust are firmly attached to the fins. If it is not handled manually, it is difficult to fall off. It can be diluted with cleaning agent according to a certain proportion, and evenly sprayed on the fins with a spray can. After waiting for 5 minutes, it can be washed with clean water. If it is still not clean, the above can be repeated until the fins are clean.

Quick freezing storehouse is widely used. There are many kinds of temperature in quick freezing storehouse, and multi temperature or double temperature can be realized to meet the needs of different customers. Fault phenomena: unit current is large and voltage is too low; Loose wiring; The unit pressure exceeds the rated pressure; The oil separation core is blocked; Device failure; Host failure; Main motor fault; Fault phenomenon: the unit cannot be started and the fuse is broken; The temperature switch is broken; Loose wiring; Thermal relay of main motor acts; The thermal relay of cold storage fan motor acts; The transformer is broken; No power input (unit); Failure not eliminated (unit); The actuator is faulty.

KedzierzynKozle.Another reason is that there are many refrigerants in the system. In this case, find the leakage point first, focus on the connection of each pipeline and valve, repair the found part, and then fill in sufficient refrigerant.

Step of cold storage design: define the volume of the cold storage warehouse. The size of the cold storage should be based on the design of a large number of agricultural products to be stored for a long time. This volume is calculated based on the essential volume of stored goods accumulated in the cold storage, plus the row to row corridors, the indoor space between the pile and the wall, the ceiling and the gap of the packaging house. After the volume of the cold storage is determined, the length and height width ratio of the cold storage shall be determined. Necessary auxiliary engineering buildings and equipment shall also be considered in the design of cold storage, such as working intermediate, packaging and combing room, special tool warehouse loading and unloading platform, etc.

General quick-frozen warehouses are mostly cooled by refrigeration mechanisms, and those with very low gasification temperature are used as coolant to evaporate under low pressure and mechanical conditions, so as to absorb the heat in the warehouse, so as to achieve the purpose of cooling and reduction.